{"product_id":"honeywell-cv-opchda-plantcruise-opc-historical-data-access-cai-industrial-data-server-module","title":"Honeywell CV-OPCHDA PlantCruise OPC Historical Data Access CAI – Industrial Data Server Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell CV-OPCHDA PlantCruise OPC Historical Data Access CAI delivers standardized, high-performance access to archived process data across industrial automation networks. Built on the OPC HDA 1.20 Classic specification, it enables multiple client applications to retrieve historical trends, alarms, and events concurrently without impacting real-time control performance. Supporting between 15 and 30 simultaneous OPC HDA client connections, this module facilitates seamless data exchange with MES, ERP, and custom analytical platforms. Its deterministic query execution ensures rapid retrieval of historical records, empowering operators and engineers to conduct precise trend analysis, quality assurance, and regulatory compliance reporting.\u003c\/p\u003e\n\u003ch2\u003eOPC HDA Architecture \u0026amp; Data Retrieval Performance\u003c\/h2\u003e\n\u003cp\u003eThe CV-OPCHDA employs a dedicated data access engine optimized for large-scale historical queries, executing complex retrieval requests in ≤5 milliseconds. Its architecture supports up to 512 harmonics monitoring alongside 64 analog and 128 digital input channels, capturing granular process changes over extended timeframes. Advanced compression algorithms reduce storage demands while preserving data fidelity. Native integration with PlantCruise and Experion LX systems eliminates middleware complexity, ensuring secure, authenticated data transactions across the enterprise network.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eValue\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHoneywell International\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCountry of Origin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUnited States\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.4 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShipping Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e7 × 14 × 14.5 cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported Protocols\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOPC HDA 1.20 Classic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConcurrent Client Connections\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e15–30\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAnalog Input Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e64\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDigital Input Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e128\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eQuery Execution Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 5 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHS Code\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8537101190\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDeployment \u0026amp; Software Integration Guidance\u003c\/h2\u003e\n\u003cp\u003eDeploy the CV-OPCHDA within a secured Windows Server environment connected directly to PlantCruise or Experion LX historians. Configure OPC client permissions using role-based access control to prevent unauthorized data extraction. Ensure adequate network bandwidth allocation for peak historical query loads, and isolate the OPC server traffic from real-time control VLANs to preserve determinism. Regularly back up configuration files and archived trend definitions to accelerate disaster recovery.\u003c\/p\u003e\n\u003ch2\u003eAnalytical Resilience \u0026amp; System Interoperability\u003c\/h2\u003e\n\u003cp\u003eProven in chemical plants, power generation facilities, and oil refining operations, the CV-OPCHDA sustains high-throughput data delivery under heavy concurrent usage. Its robust software design tolerates temporary network disruptions, resuming data services without manual intervention. Full compatibility with Honeywell’s suite of automation products ensures smooth interoperability with TSI systems, safety controllers, and advanced process control platforms, making it a cornerstone of enterprise-wide operational intelligence strategies.\u003c\/p\u003e\n\u003ch2\u003eOrdering Info\u003c\/h2\u003e\n\u003cp\u003e(1) 1 × Honeywell CV-OPCHDA OPC HDA Server Module (factory sealed)\u003c\/p\u003e\n\u003cp\u003e(2) 1 × Software license authorization certificate\u003c\/p\u003e\n\u003cp\u003e(3) 1 × Installation and configuration guide\u003c\/p\u003e\n\u003cp\u003e(4) Anti-static protective packaging with authenticity seal\u003c\/p\u003e\n\u003ch2\u003eGlobal Dispatch \u0026amp; Secure Logistics\u003c\/h2\u003e\n\u003cp\u003eConfirmed orders ship within 2–7 days of payment clearance via DHL, FedEx, or UPS with full tracking enabled. Each module is packaged in anti-static industrial-grade materials, double-boxed for maximum protection during international transit. Serialized shipping documents ensure traceability from warehouse to installation site.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes the CV-OPCHDA support OPC UA Historical Access profiles?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the CV-OPCHDA is purpose-built for OPC HDA 1.20 Classic; migration to OPC UA requires additional gateway software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the maximum data retention period supported?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRetention depends on historian storage capacity; the module itself imposes no fixed limit beyond available disk resources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module serve multiple PlantCruise nodes simultaneously?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it can aggregate historical data from multiple nodes, provided network bandwidth and client connection limits are observed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs real-time data accessible through this OPC HDA server?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CV-OPCHDA specializes in historical data; real-time values require direct OPC DA or OPC UA connections to control sy\u003cspan\u003es\u003c\/span\u003e\u003cspan\u003et\u003c\/span\u003e\u003cspan\u003ee\u003c\/span\u003e\u003cspan\u003em\u003c\/span\u003e\u003cspan\u003es\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518942273709,"sku":"CV-OPCHDA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cv-opchda-plantcruise-opc-historical-data-access-cai-vmcksq15ehl.jpg?v=1766982489","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-cv-opchda-plantcruise-opc-historical-data-access-cai-industrial-data-server-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}