{"product_id":"honeywell-cv-opcda1-plantcruise-opc-data-access-server-cai-license","title":"Honeywell CV-OPCDA1 PlantCruise OPC Data Access Server CAI License","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell CV-OPCDA1 serves as the specialized OPC Data Access (DA) Server interface for the PlantCruise and Experion LX control environments. This software license enables seamless, high-speed data exchange between the Honeywell Distributed Control System (DCS) and third-party applications, such as HMI\/SCADA systems, historians, and advanced process control tools. In critical industrial sectors like oil and gas or power generation, the CV-OPCDA1 provides the standardized communication bridge necessary for real-time monitoring of rotating machinery and process variables. By utilizing the CAI (Computer Access Interface) architecture, this server ensures low-latency throughput and robust data integrity, allowing operators to consolidate disparate plant floor information into a unified, actionable dashboard.\u003c\/p\u003e\n\u003ch2\u003eAdvanced Communication Architecture\u003c\/h2\u003e\n\u003ch3\u003eHigh-Performance Data Integration\u003c\/h3\u003e\n\u003cp\u003eThe CV-OPCDA1 architecture prioritizes deterministic data delivery and system security. It leverages the Microsoft COM\/DCOM framework to facilitate interoperability across diverse vendor hardware, effectively breaking down information silos within the plant. This server supports multiple concurrent client connections, enabling various departments to access real-time process data without degrading the controller's primary execution performance. Furthermore, the CAI implementation includes enhanced diagnostic capabilities, providing engineers with deep visibility into communication health, packet success rates, and tag synchronization status. This ensures that the integration layer remains as resilient as the underlying physical controller hardware.\u003c\/p\u003e\n\u003ch2\u003eEssential System Metrics\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCV-OPCDA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOPC Data Access (OPC DA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAI (Computer Access Interface)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlantCruise \/ Experion LX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ EU (Global Distribution)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8523.49.0000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Media\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Download \/ License Key Media Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePackage Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22cm x 15cm x 1.5cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDeployment \u0026amp; Software Environment Roadmap\u003c\/h2\u003e\n\u003cp\u003eSuccessful implementation of the CV-OPCDA1 requires a stable Windows Server environment and proper DCOM configuration. Engineers must ensure that the firewall settings permit traffic on specific RPC ports used by the OPC DA standard. We recommend installing the server on a dedicated workstation or a virtual machine with at least 8GB of RAM to handle large tag databases effectively. During the initial setup, technicians should utilize the Honeywell Configuration Studio to map internal DCS tags to the OPC namespace. It is vital to implement a redundant network path (FTE) if the system manages mission-critical interlocking data, ensuring that communication persists even during a single-point network failure.\u003c\/p\u003e\n\u003ch2\u003eOperational Value \u0026amp; Systems Synergy\u003c\/h2\u003e\n\u003cp\u003eThe CV-OPCDA1 provides an indispensable advantage for facilities aiming for Digital Transformation. Its native integration with Honeywell Experion PKS and PlantCruise systems eliminates the \"integration tax\" often associated with third-party drivers. The server maintains high reliability even in environments with heavy electromagnetic interference or extreme network loads. By providing a standardized window into the plant's heart, it allows for the seamless addition of Turbine Supervisory Instrumentation (TSI) diagnostics and predictive maintenance software, ensuring that your facility remains agile and responsive to shifting production demands.\u003c\/p\u003e\n\u003ch2\u003eLogistics \u0026amp; Industrial Handling\u003c\/h2\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish, BY DHL\/FEDEX\/UPS. All physical license kits and software media are shipped in high-grade anti-static industrial packaging to protect sensitive electronic data carriers and documentation from environmental hazards and ESD during transit.\u003c\/p\u003e\n\u003ch2\u003eTechnical Support Bench\u003c\/h2\u003e\n\u003cp\u003eQ1: Is the CV-OPCDA1 compatible with the newer OPC UA standard?\u003c\/p\u003e\n\u003cp\u003eA1: The CV-OPCDA1 is specifically designed for OPC DA (Classic). If your architecture requires OPC UA, you may need a wrapper or a different license variant like the CV-OPCUA1.\u003c\/p\u003e\n\u003cp\u003eQ2: Does this license include the software media or just the key?\u003c\/p\u003e\n\u003cp\u003eA2: This product typically includes the Certificate of Authenticity (COA) and the necessary license keys. Depending on the current Honeywell distribution, the software media may be provided as a physical disc or a secure digital download.\u003c\/p\u003e\n\u003cp\u003eQ3: Can the CV-OPCDA1 handle 2000+ process points simultaneously?\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the server is engineered for industrial-scale data throughput. However, system performance will depend on the underlying hardware capacity and the polling frequency of your OPC client application.\u003c\/p\u003e\n\u003cp\u003eQ4: What is the \"CAI\" designation in the product description?\u003c\/p\u003e\n\u003cp\u003eA4: CAI stands for Computer Access Interface. It refers to the specific Honeywell architectural layer that allows external computers to securely access the controller's internal data structures.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518949286061,"sku":"CV-OPCDA1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cv-opcda1-opc-data-access-server-cai-pvr031sim3e.jpg?v=1766982681","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-cv-opcda1-plantcruise-opc-data-access-server-cai-license","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}