{"product_id":"honeywell-cpo-rl4-cpo-room-controller-bacnet-ms-tp-hvac-module","title":"Honeywell CPO-RL4 CPO-Room Controller BACnet MS\/TP HVAC Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell CPO-RL4 stands as a premier intelligent room controller within the ControlPoint series, specifically engineered to optimize HVAC performance in demanding commercial environments. This versatile module acts as the brain for sophisticated room-level automation, effortlessly managing Fan Coil Units (FCU), chilled ceilings, and hydronic heating systems. By integrating high-density I\/O—including relays, triacs, and analog outputs—into a single 230VAC powered unit, the CPO-RL4 eliminates the need for peripheral power converters and excessive wiring. It delivers precise thermal comfort while maintaining strict energy efficiency, making it a vital component for LEED-certified buildings and high-end facility management infrastructures.\u003c\/p\u003e\n\u003ch2\u003eControl Architecture and Communication\u003c\/h2\u003e\n\u003cp\u003eThe CPO-RL4 utilizes the industry-standard BACnet MS\/TP protocol to ensure seamless interoperability across Distributed Control Systems (DCS) and Building Management Systems (BMS). Its core hardware architecture supports native integration with Honeywell’s CPO Studio software, allowing engineers to deploy custom control logic for complex 2-pipe and 4-pipe configurations. The device features an intelligent terminal design capable of powering field devices directly, significantly streamlining the control loop. With its robust Triac outputs, the controller provides silent and wear-free switching for thermal actuators, a critical requirement for noise-sensitive environments like hotels and executive offices.\u003c\/p\u003e\n\u003ch2\u003eHardware Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCPO-RL4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Relays, 6 Analog Outputs, 4 Triac Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBACnet MS\/TP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCPO Studio\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 x 18.8 x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrand New \/ Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Field Guide\u003c\/h2\u003e\n\u003cp\u003eThe CPO-RL4 requires professional mounting to ensure optimal heat dissipation and signal integrity. Installers must prioritize the separation of high-voltage (230VAC) power lines from low-voltage BACnet communication cables to prevent electromagnetic interference (EMI). When wiring Triac outputs for thermal actuators, verify that the total load does not exceed the rated current of the controller to prevent internal circuit damage.\u003c\/p\u003e\n\u003cp\u003eFor large-scale deployments, each CPO-RL4 must be assigned a unique MAC address and Instance ID within the MS\/TP network segment. Ensure proper termination of the RS485 bus using 120-ohm resistors at the end-of-line (EOL) to maintain stable data transmission across long distances.\u003c\/p\u003e\n\u003ch2\u003eIndustrial Integration Advantages\u003c\/h2\u003e\n\u003cp\u003eDespite its legacy status, the CPO-RL4 remains a highly sought-after solution for maintaining and expanding existing Honeywell ControlPoint infrastructures. Its ability to manage air quality sensors and underfloor heating concurrently provides a holistic approach to room climate control that many modern modular systems struggle to match. The controller’s rugged USA-manufactured housing withstands the fluctuating temperatures typical of ceiling plenum installations, while its precise PID algorithms minimize energy waste by preventing \"hunting\" between heating and cooling stages.\u003c\/p\u003e\n\u003ch2\u003eDelivery Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish, BY DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003cp\u003eEvery unit is shipped in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect the sensitive CMOS components from electrostatic discharge during transit.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the CPO-RL4 be used as a standalone controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes, the CPO-RL4 can operate as a standalone unit once programmed via CPO Studio, though it is primarily designed to function within a networked BACnet MS\/TP environment for centralized monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the primary advantage of Triac outputs over standard relays in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Triac outputs enable pulse-width modulation (PWM) control for thermal actuators, allowing for near-silent operation and much finer control over valve positioning compared to the binary on\/off action of mechanical relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the CPO-RL4 compatible with modern Honeywell Niagara systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, since it communicates via standard BACnet MS\/TP, it can be easily integrated into Niagara-based supervisors (like the JACE series) using standard BACnet discovery tools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does this unit support direct connection of 0-10V actuators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Correct. The module includes six analog outputs specifically designed to drive 0-10V or 2-10V modulated actuators for valves and dampers.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518953939117,"sku":"CPO-RL4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cpo-rl4-cpo-room-controller-dqxo2vvdeea.jpg?v=1766982861","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-cpo-rl4-cpo-room-controller-bacnet-ms-tp-hvac-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}