{"product_id":"honeywell-cc-puio31-51454220-176-universal-i-o-module-experion-pks","title":"Honeywell CC-PUIO31 51454220-176 Universal I\/O Module Experion PKS","description":"\u003cp\u003eConfigured for high-density signal processing in Experion PKS control networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PUIO31 51454220-176\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eCC-PUIO31\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal I\/O Module) provides direct physical\/electrical execution of mixed-signal I\/O tasks.\u003c\/p\u003e\n\u003ch3\u003eIdentification \u0026amp; Nomenclature\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: CC-PUIO31\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrder Number: 51454220-176\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel Count: 16 software-selectable channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArchitecture: Experion PKS backplane-integrated processing node\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-PUIO31 51454220-176\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 cm x 18.8 cm x 14.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDetermined by backplane budget\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 configurable channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control \u0026amp; Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module enables integrated 4-20 mA HART loop protocol support, facilitating bi-directional data exchange with field instrumentation. To ensure signal integrity, each channel implements robust channel-to-channel isolation, preventing electrical fault propagation during common-mode transients. Integrated digital filtering mechanisms are applied to incoming signals to suppress environmental noise, while the architecture allows for precise acquisition of process variables. Cold junction compensation (CJC) is managed via the terminal block assembly for temperature-sensing applications.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) CC-PUIO31 Universal I\/O module unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAntistatic moisture-barrier packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated carrier-mounting fasteners\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane locking hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExperion PKS system software integration documentation (digital format)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Alignment: Ensure the carrier slot is clear of contaminants. Insert the module into the guide rails until the backplane connector is fully seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLocking Mechanism: Secure the top and bottom locking levers to anchor the module to the I\/O carrier, ensuring reliable chassis ground continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Terminate cable shields at the cabinet entry ground bus. Maintain single-point grounding for all analog signal loops to eliminate ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: Utilize Experion PKS engineering station software to verify channel modes before wiring termination to prevent electrical damage to non-compatible loop configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes, hot-swapping is supported within the I\/O carrier if the system configuration permits a module-level power cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can analog and digital signals coexist on one module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each of the 16 channels is independently configurable via software for either analog or digital operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is external power required for digital inputs?\u003c\/p\u003e\n\u003cp\u003eA: Loop power is provided for dry-contact digital inputs; wet-contact configurations require an external 24 VDC supply per loop requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does HART communication interfere with process variables?\u003c\/p\u003e\n\u003cp\u003eA: No, HART signaling is superimposed on the 4-20 mA carrier and does not impact the polling rate of the primary process variable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum wire gauge capacity?\u003c\/p\u003e\n\u003cp\u003eA: Terminals support stranded or solid wiring up to 2.5 square millimeters (approx. 14 AWG).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are channels electrically isolated?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module features per-channel electronic protection and isolation to block fault propagation between loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can firmware be upgraded in the field?\u003c\/p\u003e\n\u003cp\u003eA: Yes, firmware updates are deployed through the controller backplane via the Experion PKS management interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module support high-frequency pulse counting?\u003c\/p\u003e\n\u003cp\u003eA: Yes, channels are capable of high-frequency pulse counting when assigned to appropriate digital input modes in the configuration software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518944600237,"sku":"51454220-176","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cc-puio31-51454220-176-universal-i-o-module-pbwfp5q4xub.jpg?v=1766982546","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-cc-puio31-51454220-176-universal-i-o-module-experion-pks","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}