{"product_id":"honeywell-bw-ga-usb1-ir-gasalert-connectivity-kit-with-ir-connectivity","title":"Honeywell BW GA-USB1-IR GasAlert Connectivity Kit with IR Connectivity","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell GA-USB1-IR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary data gateway for the BW Technologies GasAlert series, enabling high-speed infrared (IR) communication between portable gas detectors and local workstations. In high-stakes industrial environments such as chemical refineries, offshore platforms, and confined space entries, maintaining rigorous safety logs is non-negotiable. This connectivity kit allows safety officers to retrieve critical data logs, event records, and bump test results seamlessly. By facilitating a secure link to Honeywell's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFleet Manager II\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Suite\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware, the GA-USB1-IR ensures that every sensor in your fleet operates with the latest firmware and complies with strict OSHA and industrial safety regulations. This hardware interface is essential for converting raw sensor telemetry into actionable safety reports, ensuring 24\/7 protection for plant personnel and infrastructure.\u003c\/p\u003e\n\u003ch2\u003eData Interface and Connectivity Logic\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGA-USB1-IR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a high-precision infrared transceiver housed in a ruggedized USB enclosure, specifically designed to bridge the gap between portable safety hardware and digital management systems. It eliminates the need for physical contact or vulnerable charging pins during data transfer, utilizing a line-of-sight\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIR communication protocol\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat maintains signal integrity even in electrically noisy environments. The internal hardware architecture manages the conversion of IR pulses into standard USB data packets, allowing for rapid synchronization of user-defined alarm setpoints and calibration schedules. This module integrates natively with Windows-based environments, providing a plug-and-play experience for instrument technicians managing large fleets of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGasAlertMicroClip\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGasAlertMax XT II\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGasAlert Quattro\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits.\u003c\/p\u003e\n\u003ch2\u003eHardware Parameters \u0026amp; Logistics Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell (BW Technologies)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGA-USB1-IR\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInfrared (IR) to USB 2.0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGasAlertMicroClip XL\/X3, Max XT II, Quattro, Micro 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFleet Manager II \/ Honeywell Safety Suite\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 1.0 Meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.2 x 10.1 x 3.8 cm (Shipping Box)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCanada \/ Mexico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85176200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDevice Synchronization Protocol\u003c\/h2\u003e\n\u003cp\u003eTo ensure successful data transfer, instrument technicians should align the IR window of the gas detector directly with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGA-USB1-IR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransceiver at a distance of 5-10 cm. Avoid placing the kit under direct, high-intensity fluorescent lighting or sunlight, as infrared interference can cause data packet loss. Ensure that the USB driver associated with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Suite\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fully updated before connecting the hardware to the workstation. If the detector fails to acknowledge the link, verify that the IR window on the sensor is clean and free of oily residues or industrial dust. For high-volume fleet management, we recommend using a dedicated USB hub with external power to maintain consistent voltage across multiple connectivity kits during batch firmware updates.\u003c\/p\u003e\n\u003ch2\u003eSafety Compliance and System Integration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGA-USB1-IR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a cornerstone of professional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Management Systems (SMS)\u003c\/strong\u003e, providing the audit trail required for insurance and regulatory compliance. It integrates perfectly with your existing industrial IT infrastructure, allowing for the centralized storage of gas exposure data alongside DCS and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eevent logs. By automating the retrieval of peak exposure levels and TWA (Time Weighted Average) data, this kit reduces the risk of human error in manual logging. Its robust design ensures it survives the wear and tear of a technician's tool kit, serving as a reliable link in the chain of safety that protects your facility from catastrophic gas release events.\u003c\/p\u003e\n\u003ch2\u003eGlobal Shipment and Fulfillment Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDispatch Lead Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll units are processed and ready for shipment within 3-5 days when payment finish.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Logistics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe utilize premium couriers including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHL, FEDEX, and UPS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee that your safety equipment reaches your site with full tracking and insurance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Packaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery kit is encased in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand moisture-sealed to preserve the sensitive optical components during international transit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInventory Condition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNew, Sealed, and Original Pack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits. Every GA-USB1-IR is verified for batch integrity, ensuring 100% genuine Honeywell BW hardware for immediate field deployment.\u003c\/p\u003e\n\u003ch2\u003eTechnical Support Intelligence\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which gas detectors are compatible with the GA-USB1-IR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis kit is designed for use with the BW GasAlertMicroClip series (XL and X3), GasAlertMax XT II, GasAlert Quattro, and GasAlert Micro 5. It is the universal IR interface for the Honeywell BW portable line.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the kit include the Fleet Manager II software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe kit typically includes the hardware interface and a download link or CD for the base software. However, we always recommend downloading the latest version of Honeywell Safety Suite directly from the official portal for the most current driver support.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why is my computer not recognizing the USB device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis is often due to a driver conflict. Ensure you have administrative rights on your PC and that the \"Honeywell USB-to-IR Driver\" is visible in your Device Manager. If using a USB extension cable, ensure it is high-quality to prevent voltage drops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this kit calibrate the sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe GA-USB1-IR facilitates the communication for calibration—allowing you to change calibration intervals and gas concentrations via software—but the actual gas application must be done via a regulator and calibration cap or an IntelliDoX station.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518948106413,"sku":"GA-USB1-IR","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-ga-usb1-ir-bw-gasalert-connectivity-kit-lp3e2qbd4ob.jpg?v=1766982637","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-bw-ga-usb1-ir-gasalert-connectivity-kit-with-ir-connectivity","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}