{"product_id":"honeywell-51454475-100-series-8-c300-ram-charger-backup-module","title":"Honeywell 51454475-100 Series 8 C300 RAM Charger Backup Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell 51454475-100 acts as a core reliability asset within the Experion PKS Series 8 platform, delivering continuous power management to the C300 controller's volatile memory sub-systems. This RAM Charger Module guarantees absolute data retention of critical runtime parameters, strategy configurations, and historical alarm logs during total system power interruptions. Engineered for zero-downtime manufacturing sites like continuous chemical processing, offshore oil platforms, and baseline power grids, it secures the system controller against catastrophic database erasure. This module eliminates the risk of cold-start delays, allowing the process control layer to recover immediately and safely upon main power restoration.\u003c\/p\u003e\n\u003ch2\u003eInternal Power Architecture and Charge Management\u003c\/h2\u003e\n\u003cp\u003eThis hardware module employs a sophisticated, microcontroller-regulated charging circuit optimized specifically for the unique backup energy storage profiles of the C300 controller series. The solid-state power path incorporates continuous diagnostic monitoring to trace energy levels, cell health, and terminal voltage drift in real time.\u003c\/p\u003e\n\u003cp\u003eOperating directly on the Series 8 integrated backplane, the unit isolates the memory power rail from localized voltage drops, spikes, and high-frequency switching noise. The smart charging firmware dynamically modulates the current flow based on thermal feedback, preventing cell degradation from overcharging while ensuring the memory backup infrastructure maintains maximum energy readiness at all times.\u003c\/p\u003e\n\u003ch2\u003eHardware and Environmental Parameters\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454475-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Family\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries 8 \/ Experion PKS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.68 kg (1.50 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 mm x 180 mm x 55 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-impact, flame-retardant industrial polycarbonate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85044060\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25°C to 70°C (-13°F to 158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Status Diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated front-panel LED health matrix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 VAC continuous galvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Commissioning and Integration Protocol\u003c\/h2\u003e\n\u003cp\u003eMount the module directly into its designated Series 8 carrier slot, confirming that the heavy-duty backplane connectors lock cleanly without forcing the assembly. Field engineers must verify that the local system cabinet maintains unrestricted vertical airflow to dissipate the thermal load from continuous battery charging cycles. Before powering up the C300 node, verify that the grounding terminal on the module carrier exhibits a resistance path under 1 ohm to the main control room master ground bus. This precaution protects the sensitive memory backup registers against high-voltage static discharge during routine servicing.\u003c\/p\u003e\n\u003ch2\u003eStructural Hardening and Experion Cohesion\u003c\/h2\u003e\n\u003cp\u003eThe 51454475-100 incorporates extensive environmental hardening, utilizing fully encapsulated power components and conformally coated circuit layouts to withstand Class G3 harsh corrosive atmospheres. It coordinates natively with the Experion PKS asset management software layer, transmitting predictive maintenance data, battery depletion warnings, and localized hardware faults directly to the operator console. This deep integration allows maintenance supervisors to schedule drop-in replacements well before the storage cells drop below critical voltage thresholds, maintaining unbroken system safety margins.\u003c\/p\u003e\n\u003ch2\u003eLogistics Profile and Pack Checklist\u003c\/h2\u003e\n\u003cp\u003eEvery complete kit contains the following warehouse-verified items:\u003c\/p\u003e\n\u003cp\u003e(1) One authentic Honeywell 51454475-100 RAM Charger Module\u003c\/p\u003e\n\u003cp\u003e(2) Factory calibration and charge-retention verification report\u003c\/p\u003e\n\u003cp\u003e(3) Removable plastic terminal safety shield\u003c\/p\u003e\n\u003cp\u003e(4) Multilingual physical hardware installation leaflet\u003c\/p\u003e\n\u003ch2\u003ePremium Dispatch and Global Shipping\u003c\/h2\u003e\n\u003cp\u003eWe finalize quality testing and dispatch all orders within 2-7 days when payment finish verification clears our system. To prevent static discharge and mechanical shock from fracturing internal components during international transit, we seal each module inside custom-molded anti-static industrial packaging. Our supply chain routes these high-value components via premium international express services including DHL, FEDEX, or UPS, providing full commercial tracking numbers and dedicated export customs documentation.\u003c\/p\u003e\n\u003ch2\u003eControl Room Engineering FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: How can an engineer identify an impending hardware failure or cell depletion directly from the module hardware?\u003c\/p\u003e\n\u003cp\u003eA1: The module features an integrated diagnostic LED matrix on the front faceplate. A solid amber indicator or a flashing error light signals that the internal charging threshold has dropped below nominal parameters, indicating the module requires immediate replacement to protect controller memory during subsequent power cycles.\u003c\/p\u003e\n\u003cp\u003eQ2: Does changing out a depleted 51454475-100 module require a complete shutdown of the active C300 controller node?\u003c\/p\u003e\n\u003cp\u003eA2: No. The Series 8 architecture supports full hot-swap capability for this backup module, provided the primary 24 VDC system power supplies remain stable. The active C300 controller will continue its real-time logic execution unimpeded during the swap procedure.\u003c\/p\u003e\n\u003cp\u003eQ3: Does the module require specialized software initialization inside the Experion Control Builder environment?\u003c\/p\u003e\n\u003cp\u003eA3: The hardware requires no explicit software initialization or programming blocks. Once seated into the live backplane, the module auto-negotiates its power status with the C300 supervisor firmware and begins its monitoring and charge cycles instantly.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518928019629,"sku":"51454475-100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-51454475-100-series-8-c300-ram-charger-module-llmeq0ednkf.jpg?v=1766982005","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-51454475-100-series-8-c300-ram-charger-backup-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}