{"product_id":"honeywell-51305482-202-eucn-coaxial-communication-cable-20m","title":"Honeywell 51305482-202 EUCN Coaxial Communication Cable 20m","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell 51305482-202 serves as a high-integrity 20-meter Enhanced Universal Control Network (EUCN) coaxial cable, specifically engineered to maintain the backbone of legacy TDC 3000 and modern Experion PKS bridge architectures. This precision-manufactured cable facilitates the critical high-speed data exchange between Local Control Network (LCN) nodes and Universal Control Networks (UCN), ensuring deterministic communication for complex DCS control loops. In heavy industrial environments—such as petrochemical refineries and power plants—the 51305482-202 provides the electromagnetic shielding required to prevent data corruption during transient electrical events. Its robust construction guarantees signal continuity for mission-critical operations, including emergency shutdown data and real-time process visualization, making it an essential component for system expansions or critical infrastructure maintenance.\u003c\/p\u003e\n\u003ch2\u003eNetwork Topology and Physical Integrity\u003c\/h2\u003e\n\u003cp\u003eThe 51305482-202 utilizes a specialized coaxial architecture designed to meet the strict impedance requirements of the Honeywell proprietary network protocols. The \"202\" suffix denotes a factory-terminated 20-meter length, eliminating the signal loss and reliability issues associated with field-terminated connectors. This cable incorporates a high-density braided shield coupled with a foil wrap to achieve superior noise rejection in electrically dense environments. The outer jacket features flame-retardant properties suitable for installation in industrial cable trays and plenum spaces, while the gold-plated connectors ensure low-resistance contact points that resist the oxidation commonly found in humid or corrosive facility atmospheres.\u003c\/p\u003e\n\u003ch2\u003ePhysical and Operational Matrix\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51305482-202\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Meters (approx. 65.6 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEUCN Coaxial (Enhanced Universal Control Network)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohms (Optimized for LCN\/UCN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBNC \/ Proprietary Coaxial (Factory Sealed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Grade Flame Retardant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e350mm x 350mm x 80mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85442000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInfrastructure Installation Protocol\u003c\/h2\u003e\n\u003cp\u003eTechnicians must observe a minimum bending radius of 150mm during installation to prevent internal dielectric deformation, which can lead to signal reflections and network \"standing waves.\" When routing the 51305482-202 through conduits, utilize a cable lubricant to minimize mechanical stress on the factory-installed connectors. Strictly avoid running this coaxial cable parallel to high-voltage variable frequency drive (VFD) cables; maintain at least 300mm of separation to ensure the integrity of the LCN packets. For optimal performance, ensure all connection points are hand-tightened and secured to the IOTA or network tap without over-torquing, which could damage the internal center conductor.\u003c\/p\u003e\n\u003ch2\u003eSystem Synergy and Reliability\u003c\/h2\u003e\n\u003cp\u003eThe 51305482-202 excels in maintaining the high-availability requirements of the Honeywell Experion PKS platform, particularly when bridging LCN-based equipment to C300 controllers. Its durability ensures long-term performance in environments subject to high-frequency vibrations and thermal expansion. By utilizing a factory-certified 20m length, engineers reduce the total number of couplers and taps in the network segment, directly decreasing the probability of signal attenuation and system-wide timeouts. This cable remains a vital link for facilities integrating Turbine Supervisory Instrumentation (TSI) or auxiliary plant systems into a unified control room, providing the stable physical layer needed for continuous process monitoring.\u003c\/p\u003e\n\u003ch2\u003eLogistics and Global Fulfillment\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe dispatch all orders within 3-5 days when payment finish, utilizing the express services of DHL, FEDEX, and UPS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery 51305482-202 cable is coiled to factory specifications, vacuum-sealed in anti-static industrial packaging, and shipped in high-impact resistant cartons.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition Guarantee:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe provide only New, Sealed, and Original Pack inventory, ensuring that the cable’s impedance and attenuation characteristics meet original Honeywell engineering standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Chain:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOur global logistics network ensures that critical network components reach your project site with minimal lead times.\u003c\/p\u003e\n\u003ch2\u003eInfrastructure Support FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use a standard RG-6 cable instead of the 51305482-202?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. While they may look similar, the 51305482-202 is engineered with specific impedance and attenuation profiles required for Honeywell’s proprietary EUCN\/LCN timing. Using standard cable will result in frequent network errors and possible node dropouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is this cable suitable for burial in underground conduits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 51305482-202 is designed for indoor industrial environments and cable trays. If used in underground conduits, ensure the conduit is sealed against water ingress, as prolonged moisture exposure can degrade the dielectric properties over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I verify the integrity of the cable before installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe recommend a simple continuity test and an impedance check using a calibrated TDR (Time Domain Reflectometer) if the cable has been subject to heavy mechanical handling during transit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does the 20-meter length include the connectors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the 20-meter specification represents the total end-to-end length of the assembly, including the factory-installed and tested connectors.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518946074797,"sku":"51305482-202","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-51305482-202-eucn-cable-20-m-3ex0igkoxxb.jpg?v=1766982567","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-51305482-202-eucn-coaxial-communication-cable-20m","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}