{"product_id":"honeywell-51305072-200-k2lcn-local-control-network-interface-card","title":"Honeywell 51305072-200 K2LCN Local Control Network Interface Card","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell 51305072-200 acts as a high-performance K2LCN (Local Control Network) Interface Card designed exclusively for Honeywell’s legacy TDC 3000 and enhanced Experion Process Knowledge System (PKS) architectures. This critical hardware assembly establishes a high-speed, deterministic communication bridge between the processing node backplane and the primary token-passing Local Control Network. It is widely deployed in continuous process automation systems across modern oil refineries, chemical processing plants, and offshore drilling platforms.\u003c\/p\u003e\n\u003cp\u003eIn high-throughput DCS environments, data bottlenecks jeopardize system safety and operational visibility. The 51305072-200 module addresses this by executing high-speed packet processing and protocol translation directly at the hardware layer, maintaining uninterrupted parameter synchronization and alarm propagation. By deploying this robust communication card, engineering teams guarantee real-time data flow from distributed I\/O racks to operator consoles, maximizing system stability and eliminating data dropouts during critical plant events.\u003c\/p\u003e\n\u003ch2\u003eNetwork Architecture and Protocol Execution\u003c\/h2\u003e\n\u003cp\u003eThis communication card utilizes a highly specialized onboard processor to manage the strict timing constraints of Honeywell's proprietary token-passing LCN protocol. By offloading network management tasks from the main node controller, it ensures deterministic communication intervals and eliminates packet collisions across the network segment.\u003c\/p\u003e\n\u003ch3\u003eDual-Channel Medium Access\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture features redundant transceiver interfaces designed to latch onto twin coaxial LCN cables. The card continuously checks network integrity across both channels and executes an immediate, hardware-level switchover if one channel encounters signal degradation or cable damage.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Buffer Management\u003c\/h3\u003e\n\u003cp\u003eEquipped with onboard static RAM, the module optimizes data buffering to prevent data overruns during high-alarm events. This localized memory layout ensures that sequence-of-events data and critical interlock statuses remain intact and transmit chronologically to the plant historian.\u003c\/p\u003e\n\u003ch2\u003eModule Parameters and Mechanical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Identification Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51305072-200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eK2LCN-A Local Control Network Card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Network Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-Channel Token-Passing LCN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponent Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Shipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 cm x 16.5 cm x 2.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSubstrate Construction Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeavy-Duty Conformal Coated Glass Epoxy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlobal Commercial HS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8538909100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Ambient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 Degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Non-Condensing Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Ingress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOn-Site Installation and Bus Topology Rules\u003c\/h2\u003e\n\u003cp\u003eCarefully guide the card along the chassis chassis tracks until the high-density gold-plated pins seat firmly into the backplane connector. Fasten the faceplate retention screws tightly to ensure the module frame bonds correctly to the common instrument ground bar of the cabinet.\u003c\/p\u003e\n\u003ch3\u003eCoaxial Network Transceiver Coupling\u003c\/h3\u003e\n\u003cp\u003eWhen connecting the card to the physical LCN bus, technicians must verify that the BNC T-connectors and drops match the exact 75-ohm impedance specification of the network. Improper impedance matching introduces signal reflections that corrupt data frames across adjacent control nodes.\u003c\/p\u003e\n\u003ch3\u003eElectrostatic Charge Safeguards\u003c\/h3\u003e\n\u003cp\u003eBecause the onboard CMOS microchips remain highly sensitive to static discharge, engineers must wear a verified ESD wrist strap connected to a reliable earth ground before unsealing the storage enclosure or interacting with the card components.\u003c\/p\u003e\n\u003ch2\u003eCommunication Integrity and Plant Resilience\u003c\/h2\u003e\n\u003cp\u003eThe 51305072-200 module integrates advanced physical-layer filtering that isolates sensitive data logic from electromagnetic fields and radio frequency interference generated by nearby variable frequency drives and high-power switchgear.\u003c\/p\u003e\n\u003ch3\u003eUniversal Legacy Ecosystem Extension\u003c\/h3\u003e\n\u003cp\u003eThis interface card provides the critical bridge required to merge vintage TDC 3000 nodes into modern, high-bandwidth plant topologies. By maintaining identical timing constraints and register mappings, it allows seamless system scaling and hardware optimization without modifying legacy control strategies or risking software incompatibility.\u003c\/p\u003e\n\u003ch2\u003eOrdering info\u003c\/h2\u003e\n\u003cp\u003eEach standardized factory-sealed shipping container contains the following individual items:\u003c\/p\u003e\n\u003cp\u003e(1) Brand New Honeywell 51305072-200 K2LCN Card\u003c\/p\u003e\n\u003cp\u003e(2) Factory Certified Quality Validation Slip\u003c\/p\u003e\n\u003cp\u003e(3) Specialized Sealed Anti-Static Shielding Package\u003c\/p\u003e\n\u003ch2\u003eLogistics Management and Express Shipping\u003c\/h2\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish. We coordinate with elite courier networks, including DHL, FEDEX, and UPS, to provide rapid tracking and guaranteed delivery directly to industrial facilities worldwide. Each card travels inside double-walled anti-static industrial packaging complete with shock-deflecting synthetic foam inserts to survive rugged international transit conditions.\u003c\/p\u003e\n\u003ch2\u003eCommunication Interface Diagnostics FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the specific functional improvement designated by the -200 hardware suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The -200 suffix denotes an enhanced hardware revision that integrates higher-tolerance surface-mount transceivers, providing superior noise immunity and lower thermal generation compared to older -100 series components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does the 51305072-200 card behave if one of the redundant LCN cables is severed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The module instantly shifts its data transmission to the secondary coaxial channel without interrupting system operation or causing data loss. It simultaneously triggers a network channel error flag in the DCS diagnostic display to notify maintenance personnel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module require a specific firmware version loaded onto the master node controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, this board requires compatibility with the appropriate Honeywell system software release. Engineers should cross-reference their current software revision with the module's firmware compatibility matrix before swapping the hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the primary cause of intermittent communication dropouts associated with this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Intermittent dropouts typically stem from loose or oxidized BNC connections at the network tap or an missing end-of-line 75-ohm terminator on the physical LCN bus trunk line, rather than a failure within the card logic itself.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518925070509,"sku":"51305072-200","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-51305072-200-i-o-card-k2lcn-a-epqp4fhpwxz.jpg?v=1766981904","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-51305072-200-k2lcn-local-control-network-interface-card","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}