{"product_id":"honeywell-51304465-100-high-performance-shielded-twisted-pair-cable","title":"Honeywell 51304465-100 High-Performance Shielded Twisted Pair Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell 51304465-100 is a heavy-duty, shielded twisted pair communication cable engineered to maintain pristine data transmission within harsh industrial process networks. This high-spec data link forms the backbone of critical Universal Control Network (UCN) structures and proprietary high-speed data highways, facilitating flawless real-time communication between primary control processors and distributed I\/O modules. It excels in high-noise manufacturing plant floors, petroleum refineries, and automated steel mills where electromagnetic interference (EMI) frequently threatens data integrity. By enforcing strict impedance matching and maximizing signal attenuation resistance, the 51304465-100 ensures your control room receives unfiltered, microsecond-accurate data loops from emergency shutdown systems and critical chemical process sensors, keeping systemic network errors at zero.\u003c\/p\u003e\n\u003ch2\u003eCable Architecture and Physical Layer Tech\u003c\/h2\u003e\n\u003ch3\u003ePrecision Helical Twist Ratios\u003c\/h3\u003e\n\u003cp\u003eThe internal copper conductors utilize a specialized, precise helical twist spacing layout. This physical configuration maximizes common-mode rejection ratios (CMRR), forcing cross-talk and induced ambient electrical noise from neighboring motor lines to cancel themselves out natively across extended cable runs.\u003c\/p\u003e\n\u003ch3\u003eMulti-Layer Foil and Braid Shielding\u003c\/h3\u003e\n\u003cp\u003eAn advanced shielding matrix combines a 100% coverage aluminum-mylar foil wrap with a high-density tinned copper wire braid. This dual-layer defense isolates the internal data signals from high-frequency electrostatic discharges and low-frequency magnetic interference fields common in heavy-duty switchgear rooms.\u003c\/p\u003e\n\u003ch3\u003eIndustrial-Grade Fluoropolymer Insulation\u003c\/h3\u003e\n\u003cp\u003eThe exterior jacket relies on a premium, low-smoke zero-halogen (LSZH) or specialized fluoropolymer compound. This tough insulation barrier resists continuous mechanical friction, prevents chemical degradation from oil splashing, and retains full structural flexibility across wide factory thermal swings.\u003c\/p\u003e\n\u003ch2\u003ePhysical and Electrical Performance Properties\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51304465-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85444920\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.80 kg (10.58 lbs) per standard spool unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35.0 cm x 35.0 cm x 20.0 cm (13.78 in x 13.78 in x 7.87 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 Ohms (Optimized for UCN signaling)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-purity tinned stranded copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Window\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +105°C (-40°F to +221°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlame Retardancy Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL 1581 \/ VW-1 Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Ingress Protection Match\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP67 when correctly terminated in factory glands\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCable Routing and Termination Guidelines\u003c\/h2\u003e\n\u003cp\u003eField technicians must maintain a strict minimum bend radius of 75 mm (3.0 inches) during tray installation and conduit routing to protect the internal foil shielding from tearing and causing impedance drops. Never pull the cable using excessive tension; stay below the maximum recommended pulling force of 110 Newtons to prevent stretching the copper pairs.\u003c\/p\u003e\n\u003cp\u003eWhen stripping the outer jacket at junction box entry zones, score the insulation carefully using a precision stripping tool to avoid nicking the underlying tinned copper shield braid. Always route this dedicated communication cable in separate, grounded metal wireways away from high-voltage three-phase AC power lines to block inductive noise coupling.\u003c\/p\u003e\n\u003cp\u003eTerminate the outer shield braid cleanly at one single point—typically inside the main marshalling cabinet ground bus—to prevent the formation of parasitic ground loops. Seal all exposed cable ends with flame-retardant heat-shrink boots immediately if storing spools in unconditioned warehouse yards to block moisture absorption.\u003c\/p\u003e\n\u003ch2\u003eSystem Interoperability and Environmental Endurance\u003c\/h2\u003e\n\u003ch3\u003eSevere Chemical and Fluid Resistance\u003c\/h3\u003e\n\u003cp\u003eThe outer insulation outer shell blocks penetration from aggressive hydrocarbon solvents, corrosive alkaline cleaning agents, and hot synthetic lubricating oils, making it safe for open cable tray deployment near heavy industrial pumps.\u003c\/p\u003e\n\u003ch3\u003eNative Experion PKS Integration\u003c\/h3\u003e\n\u003cp\u003eThe cable design meets the strict physical layer specifications needed for legacy TDC 3000 UCN connections as well as modernized Experion PKS ControlNet links, ensuring flawless data syncing with zero packet drops between controllers.\u003c\/p\u003e\n\u003ch3\u003eContinuous Vibrational Immunity\u003c\/h3\u003e\n\u003cp\u003eThe flexible stranded conductor infrastructure handles continuous mechanical vibrations from nearby heavy rotating machinery, preventing the micro-cracking and material fatigue that often ruin solid-core communication cables over time.\u003c\/p\u003e\n\u003ch2\u003eSupply Package Inventory\u003c\/h2\u003e\n\u003cp\u003eYour industrial network cable order includes the elements outlined here:\u003c\/p\u003e\n\u003cp\u003e(1) One original Honeywell 51304465-100 shielded twisted pair communication cable assembly wound on a heavy-duty storage spool.\u003c\/p\u003e\n\u003cp\u003e(2) One factory inspection pass slip confirming bulk electrical continuity and sheath isolation resistance tests.\u003c\/p\u003e\n\u003cp\u003e(3) One specialized installation guide sheet tracking exact pinout mapping for UCN and standard industrial terminal strips.\u003c\/p\u003e\n\u003cp\u003e(4) Complete material safety data sheets (MSDS) detailing compliance parameters for low-smoke zero-halogen building codes.\u003c\/p\u003e\n\u003ch2\u003eLogistics Framework and Protective Encapsulation\u003c\/h2\u003e\n\u003cp\u003eWe process and dispatch high-grade network materials within 3-5 days after verifying payment settlement. To protect the precision copper twists and shielding layers from ambient humidity, crushing hazards, and sudden acceleration impacts during international transit, we pack each spool inside impact-absorbing wooden crates wrapped in heavy industrial shrink film. We route global shipping exclusively through premier express logistics providers including DHL, FedEx, and UPS to ensure fast, reliable, and trackable door-to-door delivery right to your plant site or logistics warehouse.\u003c\/p\u003e\n\u003ch2\u003eField Networking Assessment\u003c\/h2\u003e\n\u003ch3\u003eQ1: Can I split the 51304465-100 cable to route two separate communication channels through a single jacket?\u003c\/h3\u003e\n\u003cp\u003eNo, the 51304465-100 is engineered as a tuned, single-link pair configuration optimized for specific industrial bus impedances. Splitting the internal pairs to handle separate, asynchronous data networks will distort the cable impedance profile, causing massive signal reflections and communication failure across both lines.\u003c\/p\u003e\n\u003ch3\u003eQ2: How does this cable help if my system is showing frequent token pass errors on the UCN network?\u003c\/h3\u003e\n\u003cp\u003eFrequent token pass errors usually mean your network has low signal-to-noise ratios caused by degraded shielding or poor cable insulation. Installing the 51304465-100 replaces worn-out trunk lines with fresh, high-density braided shielding and precise 150-Ohm impedance matching, which eliminates noise entry and drops error counts back to zero.\u003c\/p\u003e\n\u003ch3\u003eQ3: Is it necessary to run the 51304465-100 inside thick rigid metal conduit if it already has a rugged jacket?\u003c\/h3\u003e\n\u003cp\u003eWhile the cable possesses excellent chemical and abrasion resistance for open tray use, running it through grounded rigid metal conduit is highly recommended when routing through areas with heavy welding equipment, high-voltage motors, or high physical traffic. The metal conduit acts as a secondary shield against heavy magnetic fields and protects the run from accidental mechanical cuts.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518940111021,"sku":"51304465-100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-51304465-100-twisted-pair-cable-2civit2tmi5.jpg?v=1766982416","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-51304465-100-high-performance-shielded-twisted-pair-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}