{"product_id":"honeywell-51202330-300-i-o-link-coaxial-cable-assembly","title":"Honeywell 51202330-300 I\/O Link Coaxial Cable Assembly","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell 51202330-300 I\/O Link Cable Assembly establishes high-speed, fault-tolerant data pathways within advanced Honeywell Experion PKS environments. Plant automation engineers install this heavy-duty communication interconnect to bridge C300 controllers, I\/O Link Modules (IOLM), and highly distributed field termination assemblies. By maintaining exact characteristic impedance and providing a completely deterministic data path, the cable layout eliminates transmission reflections and preserves microsecond-level synchronization across adjacent cabinet tiers. This premium bus component secures vital process automation loops in aggressive industrial sectors, including high-capacity oil refineries, offshore gas separation units, and multi-stage power generation centers. The 51202330-300 isolates critical control backplane traffic from crushing electromagnetic field transients, keeping emergency shutdown systems responsive and protecting processing plants from unplanned outages.\u003c\/p\u003e\n\u003ch2\u003eArchitecture and Physical Bus Hardening\u003c\/h2\u003e\n\u003cp\u003eThe 51202330-300 utilizes a high-grade coaxial architecture specifically tailored to support continuous, high-frequency serial transmissions without data packets skewing or losing amplitude. The central copper conductor features a high-purity composition to minimize electrical attenuation, paired with a low-density fluorinated ethylene propylene (FEP) dielectric core that keeps capacitance extremely stable over varying thermal shifts.\u003c\/p\u003e\n\u003cp\u003eTo achieve complete isolation against severe radio frequency interference (RFI) and magnetic fields generated by heavy-duty switchgear, Honeywell implements a multi-layered shielding network. A continuous foil wrap and an ultra-dense tinned copper braid work together to divert electrostatic noise straight to chassis ground. The outer protective jacket comprises an industrial-grade, flame-retardant compound that prevents mechanical tearing, resists oil-based chemical degradation, and stands up to long-term exposure inside unventilated marshalling panels.\u003c\/p\u003e\n\u003ch2\u003eHardware Configuration and Electrical Benchmarks\u003c\/h2\u003e\n\u003ch3\u003eMechanical Properties\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStructural Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Identifier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51202330-300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHarmonized System (HS) Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85444290\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg (1.15 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e280 mm x 280 mm x 60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Capabilities\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Assembly Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePre-terminated High-Speed I\/O Link Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Cable Physical Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 Meters (Approx. 9.8 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignaling Topology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Frequency Deterministic Serial Link Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1200 Megohms \/ km Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Ingress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Rated Chemical Resistant Outer Jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Routing and Mechanical Management\u003c\/h2\u003e\n\u003cp\u003eLay the 51202330-300 link cable assembly carefully into dedicated low-voltage wiring ducts inside the DCS cabinet, ensuring it bypasses heavy three-phase AC motor starters and variable frequency drive (VFD) output runs. Maintain a strict minimum dynamic cable bend radius of 75mm during routing to protect the internal FEP dielectric core from deformation and prevent data impedance mismatches.\u003c\/p\u003e\n\u003cp\u003eAlign the factory-terminated physical connectors squarely with the matching ports on the C300 controller base or I\/O module before pushing the connector pins into place. Hand-tighten the integrated mechanical retention hardware to build a secure, vibration-proof connection and complete the automated shield grounding loop through the module chassis frame. Do not apply excessive force or use uncalibrated tools on the locking mechanisms, as excess tension can warp the internal pins and disrupt backplane data.\u003c\/p\u003e\n\u003ch2\u003eProcess Resilience and Experion PKS Integration\u003c\/h2\u003e\n\u003cp\u003eThe 51202330-300 system exhibits superior field survivability, handling continuous industrial vibrations and environmental thermal spikes without dropping active control loops. The non-porous outer insulation blocks moisture condensation and airborne sulfur compounds from infiltrating the copper cores, preventing micro-corrosion in harsh chemical environments.\u003c\/p\u003e\n\u003cp\u003eThis communication bridge drops natively into standard Honeywell Series C I\/O configurations, allowing fast plug-and-play expansions of local or remote I\/O slots. The high-integrity shielding preserves clear, noise-free diagnostic pipelines, allowing the primary Experion software platform to extract multi-variable instrumentation variables and valve health metrics without data dropouts.\u003c\/p\u003e\n\u003ch2\u003eFulfillment Matrix and Ordering Data\u003c\/h2\u003e\n\u003cp\u003eYour high-speed process network hardware undergoes full factory continuity validation and insulation breakdown testing prior to international shipment. Your box contains:\u003c\/p\u003e\n\u003cp\u003e(1) New Original Honeywell 51202330-300 3-Meter I\/O Link Cable\u003c\/p\u003e\n\u003cp\u003e(2) Pre-installed Dual Mechanical Locking Fasteners\u003c\/p\u003e\n\u003cp\u003e(3) Factory Continuity and Shield Integrity Compliance Certificate\u003c\/p\u003e\n\u003cp\u003e(4) Removable Terminal Connection Dust Protection Caps\u003c\/p\u003e\n\u003ch2\u003eGlobal Distribution and Packing Integrity\u003c\/h2\u003e\n\u003cp\u003eWe process international express dispatch within 2-7 days when payment finish, coordinating secure air delivery via world-class couriers including DHL, FEDEX, and UPS. Technicians enclose each pre-terminated cable assembly within specialized anti-static industrial packaging sleeves to block static charges during air transit. The item is packed in rigid outer boxes lined with custom-molded, shock-absorbent foam inserts, ensuring your essential communication hardware arrives clean, dry, and ready for immediate deployment on the plant floor.\u003c\/p\u003e\n\u003ch2\u003eSystem Interconnect Technical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What structural specification does the \"-300\" identifier determine for this Honeywell cable model?\u003c\/p\u003e\n\u003cp\u003eA1: The -300 suffix dictates the exact factory-measured length and termination layout of the assembly. This specific variant delivers an exact 3.0-meter physical length (approximately 9.8 feet), making it optimal for linking stacked I\/O modules or bridging redundant controller slots within a single standard panel enclosure.\u003c\/p\u003e\n\u003cp\u003eQ2: Can field technicians trim excess length off this cable or use field-applied connectors to adjust it?\u003c\/p\u003e\n\u003cp\u003eA2: No. This high-speed I\/O link cable relies on precise factory calibration of its internal capacitance, resistance, and shielding parameters. Cutting, splicing, or installing third-party connectors alters this delicate electrical balance, leading to signal reflections, CRC packet errors, and sudden module dropouts.\u003c\/p\u003e\n\u003cp\u003eQ3: How does the cable handle shield grounding when connected to a C300 controller slot?\u003c\/p\u003e\n\u003cp\u003eA3: The pre-terminated connectors feature an integrated metallic grounding cuff that links the cable's internal foil and braid shields directly to the controller base plate upon installation. Tightening the retention fasteners completes a solid, low-impedance grounding path that filters out high-frequency EMI without needing separate ground wires.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518936342701,"sku":"51202330-300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-51202330-300-plc-module-nktwy3ilqrt.jpg?v=1766982293","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-51202330-300-i-o-link-coaxial-cable-assembly","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}