{"product_id":"honeywell-51153818-101-experion-pks-hc900-jumper-kit-pack-of-10","title":"Honeywell 51153818-101 Experion PKS HC900 Jumper Kit (Pack of 10)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell 51153818-101 Jumper Kit serves as a precision-engineered interconnect solution designed for the Honeywell HC900 and Experion PKS Series C architectures. This kit eliminates the risks associated with manual wire fabrication by providing ten pre-configured, industrial-grade 22 AWG jumpers. These components act as the critical electrical bridge between I\/O modules and the controller backplane, ensuring zero-latency signal integrity and stable power distribution. Engineered for high-availability environments—such as chemical processing and thermal management—the 51153818-101 provides a standardized connection method that prevents wiring errors during critical system commissioning or emergency maintenance. Its presence in a control cabinet guarantees a professional, vibration-resistant termination that maintains system uptime in rigorous DCS environments.\u003c\/p\u003e\n\u003ch2\u003eWiring Logic and Material Integrity\u003c\/h2\u003e\n\u003cp\u003eHoneywell utilizes 22 AWG high-purity copper conductors within the 51153818-101 kit to provide optimal current-carrying capacity for logic signals while maintaining the flexibility required for high-density cabinet layouts. Each 6-inch jumper features specialized PVC insulation, which offers superior dielectric strength and resistance to industrial contaminants.\u003c\/p\u003e\n\u003cp\u003eUnlike generic field wiring, these jumpers feature factory-crimped terminals designed to seat perfectly within Honeywell’s proprietary terminal blocks. This prevents the \"loose-wire\" phenomenon often caused by thermal cycling in industrial racks. By standardizing the physical layer of the internal controller cabinet, the 51153818-101 facilitates the HC900’s modular \"plug-and-play\" capability, allowing technicians to replace faulty I\/O modules without disturbing the permanent field wiring or the core backplane integrity.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51153818-101\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS \/ HC900 Controller Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Jumpers per Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Inches (Approx. 15.2 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial PVC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg (Packaged)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 x 14 x 14.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Engineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003cp\u003eProper utilization of the 51153818-101 kit is essential for maintaining the galvanic isolation ratings of the HC900 system. Engineers should ensure that jumpers are fully seated in the terminal housing before tightening the retention screws to the specified torque. Avoid over-tightening, as this may crush the 22 AWG core and increase path resistance.\u003c\/p\u003e\n\u003cp\u003eFor redundant controller configurations, utilize the jumpers to mirror common return paths or power rails across the redundant backplane. Ensure that jumpers do not obstruct the airflow path of the CPU module or I\/O cooling vents. In environments subject to heavy mechanical vibration, we recommend periodic torque verification of all jumper connection points during scheduled maintenance windows to prevent micro-disconnections.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe 51153818-101 Jumper Kit provides a significant reduction in \"Mean Time To Repair\" (MTTR). By using standardized lengths and pre-stripped ends, field engineers eliminate the variability of manual on-site preparation, which is the leading cause of signal noise and intermittent faults in DCS hardware.\u003c\/p\u003e\n\u003cp\u003eThe PVC insulation is rated for high-temperature cabinet environments, ensuring that the jumpers do not become brittle or degrade when placed near high-density power modules. This kit is fully compatible with Experion PKS C300 and HC900 infrastructures, providing a seamless fit that maintains the system’s original certification and safety ratings. For facilities running critical PID loops or safety-instrumented functions, using authentic Honeywell connectivity hardware is the only way to ensure the long-term stability of the control logic.\u003c\/p\u003e\n\u003ch2\u003eDelivery Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish, BY DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003cp\u003eAll kits are supplied in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original Honeywell factory-sealed boxes to prevent oxidative damage to the terminals prior to installation.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can these jumpers be used for 120\/240V AC power distribution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The 51153818-101 is designed for low-voltage logic signals and DC power distribution within the HC900\/C300 system. Always verify your specific module's current requirements against the 22 AWG rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is the 51153818-101 kit compatible with Series C I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, this kit is frequently utilized in Series C power systems and HC900 configurations to establish backplane commoning and module-level jumpers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why should I use this kit instead of standard hook-up wire?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: This kit provides standardized length and factory-tested termination. Standard field wire often varies in gauge and insulation quality, which can introduce resistance fluctuations and compromise the reliability of sensitive DCS I\/O loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How many jumpers are included in a single order?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Each 51153818-101 model number refers to a single kit containing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eten (10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindividual pre-cut jumpers.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518953840813,"sku":"51153818-101","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-51153818-101-jumper-kit-gq52woflmjv.jpg?v=1766982858","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-51153818-101-experion-pks-hc900-jumper-kit-pack-of-10","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}