{"product_id":"honeywell-10100-2-1cc10900-fail-safe-control-horizontal-bus-driver","title":"Honeywell 10100\/2\/1CC10900 Fail Safe Control Horizontal Bus Driver","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell 10100\/2\/1CC10900 is a high-reliability Horizontal Bus Driver (HBD) module specifically engineered for the Fail Safe Control (FSC) system architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis critical communication component acts as the primary data gateway between the Central Part (CPU) and the individual I\/O racks.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy bridging the vertical bus from the central controller to the horizontal bus of the I\/O modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 10100\/2\/1CC10900 ensures deterministic and high-speed data exchange essential for safety-instrumented functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eIts sophisticated design allows for seamless integration into complex safety loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the backbone for signal transparency across the control hierarchy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhether used in standard or high-availability configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module maintains the integrity of the communication link,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich is vital for preventing system-wide failures in hazardous industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications and Hardware Parameters\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 10100\/2\/1CC10900 is characterized by its extremely low power footprint and flexible cabling options to support various system redundancies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHorizontal Bus Driver (HBD)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSupply Voltage\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCurrent Consumption\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEfficient 35 mA to 65 mA (dependent on cable load)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInterface Connectivity\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFront-facing connector for Horizontal Bus; Rear connector for Vertical Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCabling Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eType A1:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor standard,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003enon-redundant I\/O rack configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eType A21\/A22:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor high-availability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eredundant I\/O rack configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eForm Factor\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompact 4TE\/3HE (standard Eurocard dimensions)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eReliability Features\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports hot-swapping for maintenance (safety protocols must be followed during live removal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Weight\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e11 kg (Net) \/ 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 kg (Shipping)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e7 x 14 x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis Horizontal Bus Driver is an indispensable component in facilities where the Fail Safe Control system protects high-value assets and human life:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEmergency Shutdown Systems (ESD)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsuring that critical sensors and final control elements remain in constant communication with the central logic solver during emergency events.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFire and Gas (F\u0026amp;G) Detection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eManaging the data flow from distributed flame and gas detectors back to the central safety station across multiple I\/O racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBurner Management Systems (BMS)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding the reliable bus communication required to monitor and control industrial boiler and furnace ignition sequences.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePetrochemical and Refining\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eServing as the communication backbone for safety-critical loops in volatile process areas where redundancy (using A21\/A22 cables) is mandatory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518955610285,"sku":"10100\/2\/1CC10900","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-10100-2-1cc10900-horizontal-bus-driver-a0mk5csbj0o.jpg?v=1766982911","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-10100-2-1cc10900-fail-safe-control-horizontal-bus-driver","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}