{"product_id":"hima-f3349-8-channel-output-digital-i-o-module","title":"HIMA F3349 8-Channel Output Digital I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-865 citation-end-865\"\u003eThe HIMA F3349 is a high-integrity Digital I\/O module specifically engineered for the H41q and H51q safety-related automation systems.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOperating within the functional safety domain, this module provides eight dedicated output channels designed to interface with safety-critical field equipment. It serves as a vital bridge between the system’s logic solver and actuators, ensuring that discrete commands are executed with the deterministic reliability required for SIL 3 (Safety Integrity Level) applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eConstructed to meet the stringent demands of German engineering, the F3349 is tailored for process industries such as chemical manufacturing, power generation, and offshore oil and gas. Its primary role is to drive solenoids, signaling devices, and contactors while maintaining continuous diagnostic surveillance of the output state.\u003c\/p\u003e\n\u003ch3\u003eTechnical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-864\"\u003e\u003c\/span\u003e\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e\u003cspan class=\"citation-864 citation-end-864\"\u003e\u003cspan\u003e \u003c\/span\u003e8 Digital Output Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-863\"\u003e\u003c\/span\u003e\u003cstrong\u003eSystem Series:\u003c\/strong\u003e\u003cspan class=\"citation-863 citation-end-863\"\u003e\u003cspan\u003e \u003c\/span\u003eH41q and H51q Safety Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cspan class=\"citation-862 citation-end-862\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for high-reliability switching of safety actuators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity:\u003c\/strong\u003e\u003cspan class=\"citation-861 citation-end-861\"\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for Safety Instrumented Systems (SIS) up to SIL 3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull isolation between internal system logic and external field circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-860\"\u003e\u003c\/span\u003e\u003cstrong\u003eDiagnostic Functions:\u003c\/strong\u003e\u003cspan class=\"citation-860 citation-end-860\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated short-circuit and open-circuit detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard HIMA 4U plug-in card for subrack mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-859\"\u003e\u003c\/span\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"citation-859 citation-end-859\"\u003e\u003cspan\u003e \u003c\/span\u003e0.16 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-859 citation-end-859\"\u003e\u003cstrong\u003eDimentions\u003c\/strong\u003e:\u003cspan\u003e2x19x12.8cm\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGermany\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFault Tolerance and Safety Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-858 citation-end-858\"\u003eThe F3349 Digital I\/O Module is characterized by its \"Fail-Safe\" design philosophy.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of a detected internal fault or communication loss with the central CPU, the module is programmed to transition its outputs to a predefined de-energized state. This ensures that the process is brought to a safe standstill, protecting personnel and assets from mechanical or chemical hazards.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eMaintenance and system availability are enhanced through the module's hot-swap capability (dependent on rack configuration), allowing for replacement without interrupting the entire safety controller's operation. The integrated status LEDs on the front panel provide technicians with immediate visual feedback regarding channel health and bus communication status. Furthermore, the F3349 utilizes specialized internal testing routines to verify the switching capability of each output, providing a high level of diagnostic coverage that minimizes the probability of dangerous undetected failures.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45519063646381,"sku":"F3349","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/hima-f3349-digital-i-o-module-chaz3idi31j.jpg?v=1766986024","url":"https:\/\/www.maxwellplc.com\/products\/hima-f3349-8-channel-output-digital-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}