{"product_id":"h7cc-aws-omron-h7cc-digital-counter","title":"H7CC-AWS | Omron | H7CC Digital Counter","description":"\u003cp\u003eConfigured for pulse totalization and high-speed process event batching in machine automation panels, the \u003cstrong\u003eOmron H7CC-AWS\u003c\/strong\u003e (\u003cstrong\u003eH7CC\u003c\/strong\u003e Digital Counter) provides direct physical\/electrical execution. It converts incoming voltage or no-voltage input pulses into visual 6-digit counts and triggers discrete solid-state transistor switching across 2-stage setpoint thresholds.\u003c\/p\u003e\n\u003ch3\u003eDesignation \u0026amp; Configuration Code Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eH7CC\u003c\/strong\u003e: Standard 48 x 48 mm DIN digital counter platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Standard functional type unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eW\u003c\/strong\u003e: 2-stage preset configuration support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e: Transistor output stage (DSPT)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply\u003c\/strong\u003e: 100 to 240 VAC direct operational input voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eH7CC-AWS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e48 mm x 48 mm x 84 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 VA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Capacity\u003c\/td\u003e\n\u003ctd\u003e6 digits (-99999 to 999999)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClassification\u003c\/td\u003e\n\u003ctd\u003ePreset counter \/ Tachometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003e1-stage, 2-stage, Total\/preset, Batch, Dual, Twin, Tachometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Specifications\u003c\/td\u003e\n\u003ctd\u003eTransistor output (DSPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMemory Integrity \u0026amp; Deterministic Logic Processing\u003c\/h3\u003e\n\u003cp\u003eThe counter architecture processes high-frequency input transitions through an embedded logic control engine. Internal EEPROM non-volatile memory retains setpoint values and cumulative count records during control supply interrupts. Maintained firmware flash compatibility ensures synchronized parameter register handling, keeping local count updates aligned with backplane bus communication velocity Licences across broader PLC-driven control networks.\u003c\/p\u003e\n\u003ch3\u003eSupplied Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron H7CC-AWS 6-digit preset counter unit\u003c\/li\u003e\n\u003cli\u003e1 x Flush mounting adapter sleeve\u003c\/li\u003e\n\u003cli\u003e1 x Waterproof packing gasket\u003c\/li\u003e\n\u003cli\u003e1 x Terminal block cover plate\u003c\/li\u003e\n\u003cli\u003e1 x Instruction manual sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Mounting \u0026amp; Terminal Wiring Protocols\u003c\/h3\u003e\n\u003ch4\u003eCutout Assembly \u0026amp; Waterproof Sealing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePrepare a standard 45 x 45 mm DIN cutout in the enclosure panel face, ensuring clean edges without burrs.\u003c\/li\u003e\n\u003cli\u003eFit the rubber gasket over the housing body before pushing the terminal through the panel cutout, then slide the rear mounting adapter forward until firmly locked.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower \u0026amp; Signal Connection Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect 100 to 240 VAC operating power to the designated supply terminals using isolated copper conductors.\u003c\/li\u003e\n\u003cli\u003eRoute high-speed sensor input lines in separate shielded conduits away from AC power lines and heavy inductive switching circuits to mitigate signal noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat primary operating voltage is supported by the H7CC-AWS counter?\u003c\/p\u003e\n\u003cp\u003eThe unit operates directly on an AC line supply ranging from 100 to 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output switching type is integrated into the H7CC-AWS module?\u003c\/p\u003e\n\u003cp\u003eThe hardware utilizes a discrete NPN\/PNP transistor output stage configured for 2-stage preset control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many display digits are provided on the front viewing panel?\u003c\/p\u003e\n\u003cp\u003eThe front panel features a 6-digit visual display capable of presenting values from -99999 to 999999.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich functional counting configurations can be selected in the setup menu?\u003c\/p\u003e\n\u003cp\u003eModes include 1-stage, 2-stage, total\/preset, batch, dual, twin counting, and tachometer frequency display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are field signal wires terminated on the rear of the device?\u003c\/p\u003e\n\u003cp\u003eAll electrical connections attach to standard finger-safe screw terminals located on the rear chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mechanism retains count data during an AC supply power outage?\u003c\/p\u003e\n\u003cp\u003eAn internal non-volatile EEPROM automatically preserves preset values and active count counts without batteries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the counter require specific firmware flash compatibility for program loading?\u003c\/p\u003e\n\u003cp\u003eInternal firmware must match hardware toolchain parameters to support configuration programming and data validation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical mounting standard does the counter enclosure conform to?\u003c\/p\u003e\n\u003cp\u003eThe device conforms to the standard 48 x 48 mm DIN panel front-mounting footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306594779309,"sku":"H7CC-AWS","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/H7CC-AWS_1.jpg?v=1790174483","url":"https:\/\/www.maxwellplc.com\/products\/h7cc-aws-omron-h7cc-digital-counter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}