{"product_id":"gjr5144900r0001-35st90-abb-connector-procontic-t300","title":"GJR5144900R0001 35ST90 ABB Connector Procontic T300","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB GJR5144900R0001 35ST90\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGJR5144900R0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnector, operates as a dedicated hardware component for signal path routing and electrical termination within Procontic T300 DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Data\u003c\/h3\u003e\n\u003cp\u003eThe GJR5144900R0001 (35ST90) is a passive interconnection module. The part number designates a specific connector assembly tailored for T300 architecture. There are no configurable sub-assemblies for this hardware; it functions as a single-unit interface for field wiring termination to the system backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGJR5144900R0001 35ST90\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26.1 x 6.2 x 2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcontic T300 \/ DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector \/ Ethernet Router Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThis connector supports backplane bus communication velocity requirements for Procontic T300 nodes. It facilitates deterministic signal transfer by providing a stable physical interface between field-side wiring and system I\/O modules. While the module itself is passive, its geometry allows for high I\/O density scaling within constrained cabinet spaces. The physical design ensures firmware flash compatibility with the host system by providing a transparent signal path that does not interfere with data transmission protocols or real-time diagnostic cycles.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGJR5144900R0001 Connector unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical specification and installation document\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective packaging for transport\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Fix the connector assembly securely to the cabinet rail. Ensure the space-constrained form factor allows for adequate cable bend radii.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTermination: Verify all conductor connections to the connector pins are tightened to manufacturer specifications to prevent high-resistance joints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain consistent shielding for all connected signals to ensure immunity against electromagnetic interference in the cabinet environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspection: Perform visual verification of pin alignment before mating the connector with the Procontic T300 I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance: Keep the connector area free of dust and moisture; use a non-conductive contact cleaner if oxidation is detected during routine inspections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this connector hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the Procontic T300 rack must be isolated before mating or un-mating the connector to prevent potential electrical arcing or system faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the connector influence signal propagation delay?\u003c\/p\u003e\n\u003cp\u003eA: As a passive interconnect, it introduces negligible signal latency; signal timing is governed by the host I\/O module and backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this be used for high-speed Ethernet routing?\u003c\/p\u003e\n\u003cp\u003eA: It serves as a physical interface for signals within systems supporting Ethernet router communication; ensure cable specifications match the required data rate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the connector shell shielded?\u003c\/p\u003e\n\u003cp\u003eA: The connector assembly is designed for use in industrial control cabinets; ensure system grounding protocols are followed for proper shield continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum wire gauge supported?\u003c\/p\u003e\n\u003cp\u003eA: Refer to the Procontic T300 hardware manual for the specific wire cross-section limits allowed by the connector terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I troubleshoot intermittent connectivity?\u003c\/p\u003e\n\u003cp\u003eA: Check for loose terminal screws, wire breaks, or physical debris inside the connector housing that may impede electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the connector require maintenance?\u003c\/p\u003e\n\u003cp\u003eA: Routine inspections for corrosion and mechanical integrity are recommended as part of the standard industrial cabinet maintenance cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is it possible to use this in a non-T300 system?\u003c\/p\u003e\n\u003cp\u003eA: The connector is designed for Procontic T300 architecture; utilization in other systems may result in pin mismatch or mechanical incompatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231181037741,"sku":"GJR5144900R0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-gjr5144900r0001-35st90-connector-ftrfxq5bzj2_e8e649cf-c5b1-47c5-9b48-327ddd1a8553.jpg?v=1762942338","url":"https:\/\/www.maxwellplc.com\/products\/gjr5144900r0001-35st90-abb-connector-procontic-t300","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}