{"product_id":"general-electric-multilin-pqmii-t20-c-a-power-quality-monitor","title":"General Electric Multilin PQMII-T20-C-A Power Quality Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe PQMII-T20-C-A is a power quality monitoring device used to measure and analyze electrical parameters in single-phase or three-phase power systems. It is designed for industrial facilities that require continuous visibility of voltage, current, demand, power, and energy values, with optional diagnostic functions for identifying power quality events that can impact sensitive loads.\u003c\/p\u003e\n\u003cp\u003eThis unit supports integration into plant monitoring and control systems through serial communications and relay-based alarming. With programmable setpoints and onboard control outputs, the PQMII-T20-C-A can be applied for supervisory functions such as alarm annunciation, load control, and equipment protection interlocks based on measured electrical conditions.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBrand: General Electric (Multilin)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDevice Category: Power Quality Monitor \/ Power Quality Meter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: PQMII-T20-C-A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement System Support: Single-phase and three-phase monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasured Quantities (typical): Voltage, current, power, demand, energy, and power factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHarmonic Capability: Harmonic analysis option for distortion measurement and assessment (configuration-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEvent Diagnostics: Waveform\/event capture capability for troubleshooting power quality disturbances (feature-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl and I\/O Functions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable setpoints for alarm and control logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay Outputs: 4 assignable relays for alarm, control, or interlocking functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Inputs: 4 switch inputs for status monitoring or control schemes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Outputs: Up to 4 analog outputs, commonly 4–20 mA for PLC\/DCS interfacing (configuration-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCommunications and Integration:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual RS485 ports with Modbus protocol support for SCADA\/PLC connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront-access RS232 port for local configuration and data access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupply and Logistics:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifecycle Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Order Quantity: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 3.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 35 × 15 × 15 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Type: DCS \/ Power Monitoring Integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower quality monitoring for plants with VFDs, UPS systems, and sensitive automation loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFeeder and MCC incomer monitoring for voltage events, demand trends, and energy accounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA integration using Modbus over RS485 for centralized electrical monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm and control schemes using relay outputs for load shedding or abnormal-condition annunciation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommissioning and troubleshooting where waveform capture and harmonic metrics support root-cause analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519086026925,"sku":"PQMII-T20-C-A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-pqmii-t20-c-a-power-quality-monitor-0ybwtvyb32h.jpg?v=1766986601","url":"https:\/\/www.maxwellplc.com\/products\/general-electric-multilin-pqmii-t20-c-a-power-quality-monitor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}