{"product_id":"general-electric-ic695niu001-ethernet-network-interface-unit-pacsystems","title":"General Electric IC695NIU001 Ethernet Network Interface Unit PACSystems","description":"\u003ch3 data-start=\"110\" data-end=\"132\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"133\" data-end=\"507\"\u003eThe IC695NIU001 is an Ethernet Network Interface Unit (NIU) used to connect distributed I\/O assemblies to a control system over an Ethernet network. In PACSystems architectures, the NIU functions as a remote I\/O communications node, exchanging I\/O data and status information between networked controllers and the installed I\/O modules once the configuration is established.\u003c\/p\u003e\n\u003cp data-start=\"509\" data-end=\"826\"\u003eThis unit is commonly applied where remote racks or distributed I\/O stations are required to reduce field wiring, extend system reach, and support scalable automation layouts. It is designed for industrial networks where deterministic data exchange and ongoing link diagnostics are important for continuous operation.\u003c\/p\u003e\n\u003ch3 data-start=\"828\" data-end=\"853\"\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul data-start=\"854\" data-end=\"2395\"\u003e\n\u003cli data-start=\"854\" data-end=\"867\"\u003e\n\u003cp data-start=\"856\" data-end=\"867\"\u003eBrand: GE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"898\"\u003e\n\u003cp data-start=\"870\" data-end=\"898\"\u003eProduct Family: PACSystems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"899\" data-end=\"957\"\u003e\n\u003cp data-start=\"901\" data-end=\"957\"\u003eModule Category: Ethernet Network Interface Unit (NIU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"958\" data-end=\"995\"\u003e\n\u003cp data-start=\"960\" data-end=\"995\"\u003eModel \/ Order Number: IC695NIU001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"996\" data-end=\"1076\"\u003e\n\u003cp data-start=\"998\" data-end=\"1076\"\u003ePrimary Function: Ethernet-based remote I\/O interface and data exchange node\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1077\" data-end=\"1198\"\u003e\n\u003cp data-start=\"1079\" data-end=\"1198\"\u003eSupported Architectures (as stated): PACSystems RX3i and Series 90-30 networked I\/O configurations (system-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1200\" data-end=\"1464\"\u003e\n\u003cp data-start=\"1202\" data-end=\"1248\"\u003eNetwork and Protocol Support (as specified):\u003c\/p\u003e\n\u003cul data-start=\"1251\" data-end=\"1464\"\u003e\n\u003cli data-start=\"1251\" data-end=\"1282\"\u003e\n\u003cp data-start=\"1253\" data-end=\"1282\"\u003eEthernet Speed: 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1375\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1375\"\u003eEthernet Global Data (EGD) capability for cyclic data exchange (application-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1378\" data-end=\"1464\"\u003e\n\u003cp data-start=\"1380\" data-end=\"1464\"\u003eProvides continuous communication status reporting for controller-side diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1466\" data-end=\"1767\"\u003e\n\u003cp data-start=\"1468\" data-end=\"1502\"\u003ePort and Communication Features:\u003c\/p\u003e\n\u003cul data-start=\"1505\" data-end=\"1767\"\u003e\n\u003cli data-start=\"1505\" data-end=\"1596\"\u003e\n\u003cp data-start=\"1507\" data-end=\"1596\"\u003eDual Ethernet port design for network connectivity and flexible installation topologies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1599\" data-end=\"1674\"\u003e\n\u003cp data-start=\"1601\" data-end=\"1674\"\u003eAutomatic background handling of I\/O data transfers after configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1677\" data-end=\"1767\"\u003e\n\u003cp data-start=\"1679\" data-end=\"1767\"\u003eStatus visibility allows controller logic to monitor NIU health and network conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1769\" data-end=\"2069\"\u003e\n\u003cp data-start=\"1771\" data-end=\"1794\"\u003eSupply and Logistics:\u003c\/p\u003e\n\u003cul data-start=\"1797\" data-end=\"2069\"\u003e\n\u003cli data-start=\"1797\" data-end=\"1821\"\u003e\n\u003cp data-start=\"1799\" data-end=\"1821\"\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1824\" data-end=\"1850\"\u003e\n\u003cp data-start=\"1826\" data-end=\"1850\"\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1853\" data-end=\"1881\"\u003e\n\u003cp data-start=\"1855\" data-end=\"1881\"\u003eLifecycle Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1884\" data-end=\"1907\"\u003e\n\u003cp data-start=\"1886\" data-end=\"1907\"\u003eProduct Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1939\"\u003e\n\u003cp data-start=\"1912\" data-end=\"1939\"\u003eMinimum Order Quantity: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1942\" data-end=\"1965\"\u003e\n\u003cp data-start=\"1944\" data-end=\"1965\"\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1968\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1970\" data-end=\"1987\"\u003eWeight: 0.44 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1990\" data-end=\"2026\"\u003e\n\u003cp data-start=\"1992\" data-end=\"2026\"\u003eDimensions: 7.0 × 13.2 × 13.7 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2029\" data-end=\"2069\"\u003e\n\u003cp data-start=\"2031\" data-end=\"2069\"\u003eSystem Type: DCS \/ PLC Networked I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2071\" data-end=\"2395\"\u003e\n\u003cp data-start=\"2073\" data-end=\"2093\"\u003eIntegration Notes:\u003c\/p\u003e\n\u003cul data-start=\"2096\" data-end=\"2395\"\u003e\n\u003cli data-start=\"2096\" data-end=\"2168\"\u003e\n\u003cp data-start=\"2098\" data-end=\"2168\"\u003eUsed as part of a configured PACSystems Ethernet remote I\/O solution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2171\" data-end=\"2279\"\u003e\n\u003cp data-start=\"2173\" data-end=\"2279\"\u003eConfiguration, node addressing, and data mapping are completed in the PACSystems engineering environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2282\" data-end=\"2395\"\u003e\n\u003cp data-start=\"2284\" data-end=\"2395\"\u003eNetwork design should follow industrial Ethernet best practices for grounding, segregation, and cable routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2397\" data-end=\"2426\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul data-start=\"2427\" data-end=\"2885\"\u003e\n\u003cli data-start=\"2427\" data-end=\"2520\"\u003e\n\u003cp data-start=\"2429\" data-end=\"2520\"\u003eRemote I\/O stations in manufacturing cells and conveyor systems to reduce home-run wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2521\" data-end=\"2606\"\u003e\n\u003cp data-start=\"2523\" data-end=\"2606\"\u003eDistributed automation skids and packaged systems requiring modular I\/O expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2607\" data-end=\"2689\"\u003e\n\u003cp data-start=\"2609\" data-end=\"2689\"\u003eUtility and water\/wastewater facilities using Ethernet-connected remote panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2690\" data-end=\"2791\"\u003e\n\u003cp data-start=\"2692\" data-end=\"2791\"\u003eRetrofit projects where legacy I\/O and newer PACSystems controllers share a common network design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2792\" data-end=\"2885\"\u003e\n\u003cp data-start=\"2794\" data-end=\"2885\"\u003eSystems requiring network health monitoring and diagnostic visibility from the controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519080259757,"sku":"IC695NIU001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695niu001-ethernet-network-interface-unit-r1p11lu12rq.jpg?v=1766986459","url":"https:\/\/www.maxwellplc.com\/products\/general-electric-ic695niu001-ethernet-network-interface-unit-pacsystems","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}