{"product_id":"general-electric-ds200tceag1btf-emergency-overspeed-board-mark-v-system","title":"General Electric DS200TCEAG1BTF Emergency Overspeed Board Mark V System","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe General Electric DS200TCEAG1BTF is a high-integrity Emergency Overspeed Board engineered for the Speedtronic™ turbine control architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePrimarily utilized within the Mark V Series,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module functions as a critical safety layer designed to detect and mitigate mechanical overspeed conditions in gas and steam turbines.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt represents a mature evolution of the TCEAG1 series,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincorporating specific hardware revisions to enhance processing stability.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy monitoring frequency inputs from speed sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe DS200TCEAG1BTF executes emergency trip logic independently of the primary control processors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that the turbine is brought to a safe state if operational parameters exceed predefined rotational limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Infrastructure and Board Layout\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDS200TCEAG1BTF\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eComponent Type\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEmergency Overspeed Protection PCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Family\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMark V Series (Speedtronic™ Technology)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessing Core\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDedicated onboard microprocessor for independent safety logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMemory Architecture\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMultiple EPROM sockets for programmable firmware modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOvercurrent Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThree integrated high-reliability fuses with dedicated circuit IDs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConfigurability\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e30 onboard jumpers for field-selectable operational parameters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInterface Ports\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual bayonet-style connectors for high-integrity signal input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMass\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e27.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 cm x 21.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm x 4.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Lifecycle\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupporting active and mature turbine installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eMission-Critical Safety Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe DS200TCEAG1BTF is deployed in high-consequence industrial environments where fail-safe performance is the highest priority:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTurbine Trip Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003eActing as the primary hardware interface for emergency trip solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etriggering an immediate shutdown if the microprocessor identifies a rotational velocity that threatens the structural integrity of the turbine shaft.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Speed Monitoring\u003c\/strong\u003e\u003cspan class=\"\"\u003eUtilizing independent signal paths via bayonet connectors to cross-reference sensor data against programmable EPROM setpoints,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a deterministic response regardless of the status of the central DCS.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVoltage Fluctuation Resilience\u003c\/strong\u003e\u003cspan class=\"\"\u003eLeveraging an array of onboard fuses to isolate internal logic from field-side electrical surges,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring the safety board remains operational even during power distribution anomalies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLegacy System Sustainment\u003c\/strong\u003e\u003cspan class=\"\"\u003eProviding an essential spare for Speedtronic™ Mark V systems where modern safety protocols must be maintained on legacy turbine frames without a full control system migration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic Validation and Setup\u003c\/strong\u003e\u003cspan class=\"\"\u003eAllowing site engineers to utilize the extensive jumper array and EPROM modules to customize trip curves for specific turbine sizes and operational load profiles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519070462125,"sku":"DS200TCEAG1B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ds200tceag1btf-emergency-overspeed-board-wie0xip0ty2.jpg?v=1766986191","url":"https:\/\/www.maxwellplc.com\/products\/general-electric-ds200tceag1btf-emergency-overspeed-board-mark-v-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}