{"product_id":"general-electric-ds200shvmg1acc-m-frame-high-voltage-interface-board","title":"General Electric DS200SHVMG1ACC M-Frame High Voltage Interface Board","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe DS200SHVMG1ACC is a specialized High Voltage Interface Module engineered by General Electric for the Speedtronic Mark V control system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePrimarily serving M-frame drive architectures,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis board facilitates the critical link between the Silicon Controlled Rectifier (SCR) bridge and the primary power distribution cards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as the DCFB or SDCI power supply modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy integrating GE's advanced signal processing technology,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe DS200SHVMG1ACC ensures precise monitoring of motor armature currents and high-voltage feedback,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich is essential for the stable operation of steam,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003egas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand wind turbine automated drives.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the Mark V series has transitioned to a legacy phase,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis \"ACC\" revised board remains a vital component for maintaining the operational life of distributed control systems (DCS) worldwide.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eComponent Architecture and Signal Processing Metrics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe DS200SHVMG1ACC is designed with precision circuitry to handle high-voltage feedback and current shunt signals:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVCO Signal Conversion\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures on-board Voltage-Controlled Oscillator (VCO) circuits that transform millivolt shunt signals (ranging from -500 to 500 mV) into differential frequency outputs between 0 and 500 kHz.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCurrent Attenuation\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports AC line current monitoring via a 10:\u003c\/span\u003e\u003cspan class=\"\"\u003e1 current transformer attenuation circuit,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring safe signal levels for downstream power connect cards (PCCA).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModular Interconnects\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes standardized IA2PL-1 and IA2PL-2 connectors specifically for Motor Armature Current Shunt Differential VCO Positive and Negative outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOn-board Configuration\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIncludes 17 hardware jumpers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing field technicians to calibrate the board for specific drive frame requirements and signal scaling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStructural Profile\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA compact PCB assembly weighing 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e34 kg with physical dimensions of 23.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 x 17.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 x 4 cm,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoptimized for rack-mounted drive enclosures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Voltage Isolation\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to interface directly with M-frame SCR bridges while maintaining electrical separation between power and control logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and System Utility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis interface board is a critical asset for power generation and heavy industrial drive maintenance:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Role\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTurbine Control Systems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManaging the automated start-up and speed regulation of Mark V series gas and steam turbines.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eM-Frame Drive Maintenance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProviding a direct-replacement interface for SCR bridges in heavy-duty GE motor drives.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Conversion Units\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConditioning shunt signals for the DCFB power supply board to ensure accurate armature current feedback.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWind Energy Assets\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupporting the power electronics layer in legacy wind turbine control architectures.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDCS Infrastructure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActing as a high-voltage signal bridge in complex industrial distributed control environments.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519041265837,"sku":"DS200SHVMG1A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ds200shvmg1acc-extended-analog-i-o-board-f5hjlmlkoio.jpg?v=1766985556","url":"https:\/\/www.maxwellplc.com\/products\/general-electric-ds200shvmg1acc-m-frame-high-voltage-interface-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}