{"product_id":"ge-ls2100-gate-pulse-amplifier-board-ds200fgpag1a-ds200fgpag1agd-pulse-board","title":"GE LS2100 Gate Pulse Amplifier Board DS200FGPAG1A | DS200FGPAG1AGD Pulse Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-410 citation-end-410\"\u003eThe DS200FGPAG1A, an essential component of the GE LS2100 and Mark V control ecosystems, serves as a high-performance Gate Pulse Amplifier (FGPA) board.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis module is specifically engineered to bridge the gap between low-level control logic and high-power Silicon Controlled Rectifier (SCR) switching. By amplifying firing pulses and ensuring precise timing, the board facilitates the efficient operation of Load Commutated Inverters (LCI) and large-scale power converters.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-409 citation-end-409\"\u003eBeyond simple amplification, the DS200FGPAG1A provides comprehensive diagnostic oversight through integrated SCR status monitoring and a specialized fiber optic interface that ensures electrical isolation between control circuits and high-voltage power components.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters and Key Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-408 citation-end-408\"\u003eThe DS200FGPAG1A is designed for high-voltage environments, incorporating advanced signal filtering and a multi-channel optical interface to maintain system integrity.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGate Pulse Amplification and SCR Monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-407\"\u003e\u003c\/span\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003cspan class=\"citation-407 citation-end-407\"\u003e\u003cspan\u003e \u003c\/span\u003e120 VRMS nominal source\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e350 VA Maximum Capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConverter Compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for 2080 VAC or 3300 VAC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-406\"\u003e\u003c\/span\u003e\u003cstrong\u003eOptical Interface\u003c\/strong\u003e\u003cspan class=\"citation-406 citation-end-406\"\u003e\u003cspan\u003e \u003c\/span\u003e15 Fiber Optic Ports (1 Transmitter \/ 14 Receivers)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-405\"\u003e\u003c\/span\u003e\u003cstrong\u003eDiagnostic Monitoring\u003c\/strong\u003e\u003cspan class=\"citation-405 citation-end-405\"\u003e\u003cspan\u003e \u003c\/span\u003e30 Dedicated Hardware Test Points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFiber optic coupling for high-voltage transient protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReference Manual\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGEI-100223\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-404\"\u003e\u003c\/span\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003cspan class=\"citation-404 citation-end-404\"\u003e\u003cspan\u003e \u003c\/span\u003eLS2100 Static Starter and Mark V Control Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevision Status\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDS200FGPAG1AGD (Multiple sub-revisions supported)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp\u003eThis amplifier board is a critical element in high-demand power conversion and motor starting sequences within heavy industrial facilities.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatic Starter Systems (LCI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDriving the SCR gates in Load Commutated Inverters used to start large gas turbines and synchronous motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Power Conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging the firing sequences for power converters operating in the 2kV to 3.3kV range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSCR Health Diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuously monitoring the feedback from 14 individual receivers to detect failed thyristors or firing irregularities in real-time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUtility-Scale Generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eImplementation within Mark V and LS2100 cabinets to ensure reliable control of auxiliary power systems and turbine starters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-403\"\u003e\u003c\/span\u003e\u003cstrong\u003eElectrical Isolation Management\u003c\/strong\u003e\u003cspan class=\"citation-403 citation-end-403\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing fiber optic channels to eliminate electromagnetic interference (EMI) and prevent high-side voltage from reaching control processors.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProper handling is mandatory to maintain the board's sensitive electronics; the module should remain in its static-protective shielding until the point of installation, and fiber optic cables must adhere to specified bend radii to prevent signal attenuation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45643024367789,"sku":"DS200FGPAG1AGD","price":1199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/DS200FGPAG1A-33.jpg?v=1769050471","url":"https:\/\/www.maxwellplc.com\/products\/ge-ls2100-gate-pulse-amplifier-board-ds200fgpag1a-ds200fgpag1agd-pulse-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}