{"product_id":"fs-cci-uni-02-honeywell-universal-safety-communication-interface-cable","title":"FS-CCI-UNI-02 Honeywell Universal Safety Communication Interface Cable","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell FS-CCI-UNI-02 is a specialized high-integrity communication interface engineered for the Safety Manager and Experion PKS ecosystems.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFar more than a standard interconnect,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis \"Universal\" communication link serves as the primary data conduit between safety logic solvers and distributed safety assets.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to facilitate the deterministic exchange of safety-critical variables,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that the Safety Instrumented System (SIS) maintains a comprehensive and real-time map of field conditions.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe FS-CCI-UNI-02 is a vital component for facilities operating under SIL 3 requirements,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the hardened physical layer necessary to prevent data corruption or communication latency during emergency shutdown (ESD) sequences.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eConnectivity Benchmarks and Engineering Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe FS-CCI-UNI-02 is manufactured with high-grade shielding and industrial-strength connectors to ensure consistent throughput in environments prone to high electromagnetic interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInterface Category:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUniversal Safety Communication Link\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Integrity Level:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCertified for use in SIL 3 rated safety loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtocol Support:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for Honeywell Safety Manager internal bus and cross-platform translation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced high-density shielding to mitigate RFI\/EMI noise\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports dual-path communication architectures for fault-tolerant operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Reliability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade strain relief and gold-plated contact points for oxidation resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eComponent Weight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e15 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUnit Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12 x 19 x 2 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTariff Identification:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHS Code 8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Safety Applications and Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis universal interface cable is utilized in complex industrial environments where the synchronization of disparate safety assets is a prerequisite for operational stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDistributed Safety Networking:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eLinking centralized Safety Manager processors to remote I\/O clusters across large-scale oil and gas tank farms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThird-Party Equipment Interfacing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFacilitating the secure exchange of safety data between Honeywell controllers and specialized third-party rotating machinery protection systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEmergency Shutdown (ESD) Coordination:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding the reliable data path required to synchronize multi-zone shutdowns in chemical processing facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFire and Gas System Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConnecting gas detection hubs to the main safety logic solver to ensure rapid alarm propagation and suppression trigger execution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Expansion and Retrofits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eServing as the standard communication link for adding new safety modules to existing Experion PKS cabinets without compromising loop integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518927593645,"sku":"FS-CCI-UNI-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-fs-cci-uni-02-communication-cable-pf5penmwl1p.jpg?v=1766981988","url":"https:\/\/www.maxwellplc.com\/products\/fs-cci-uni-02-honeywell-universal-safety-communication-interface-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}