{"product_id":"fc-tuio11-honeywell-safety-universal-i-o-termination-module","title":"FC-TUIO11 Honeywell Safety Universal I\/O Termination Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FC-TUIO11 is a high-integrity Safety Universal I\/O module designed for the Safety Manager and Experion PKS platforms. Serving as a cornerstone of Honeywell’s Universal Marshalling Solution (UMS), this module eliminates the need for specialized, signal-specific hardware by supporting analog, digital, and HART-enabled communications within a single interface. The FC-TUIO11 is engineered to provide a secure and flexible bridge between field instrumentation and the logic controller, facilitating high-speed data acquisition and precise signal conditioning. Its design is specifically optimized for Safety Instrumented Systems (SIS), where reliability and standardized termination are paramount for protecting critical industrial assets.\u003c\/p\u003e\n\u003ch3\u003eHardware Configuration and Technical Benchmarks\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC Nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e55mA Rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±20μA (measured at 20°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDielectric Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500V AC (between field, power, and DCS circuits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated HART pass-through for smart instrument diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-facing Green LED Power Status Indicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal I\/O (UIO) supporting Analog and Discrete signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19.1 x 18.8 x 6.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHS Tariff Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Deployment and Process Utility\u003c\/h3\u003e\n\u003cp\u003eThe FC-TUIO11 is predominantly deployed in safety-critical sectors such as offshore oil platforms, LNG terminals, and complex chemical refineries. By utilizing the Universal I\/O architecture, engineers can configure channels via software rather than physical rewiring, which drastically simplifies \"late-stage\" design changes and brownfield system expansions. This module is particularly effective in Emergency Shutdown (ESD) and Fire and Gas (F\u0026amp;G) systems, where its high isolation ratings and precision signal transfer ensure that safety loops remain uncompromised even in harsh electrical environments. Its compact form factor allows for high-density marshalling in standardized control cabinets, reducing the overall footprint of the DCS infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the FC-TUIO11 support redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the FC-TUIO11 is designed to work within redundant I\/O termination assemblies (IOTA) to ensure that safety functions remain active even if a single module requires maintenance or replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module communicate with HART-enabled transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. The FC-TUIO11 features native support for HART communications, allowing for advanced device diagnostics and remote configuration of smart field instruments directly through the DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if the module loses power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module is equipped with a green LED indicator for local power verification. In a Safety Manager environment, power loss is detected by the controller, which will typically initiate a fail-safe state according to your specific safety logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with standard Experion PKS C300 controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While it is part of the Experion ecosystem, the FC-TUIO11 is specifically tailored for Safety Manager and Safety Universal I\/O environments. You should verify your specific IOTA and controller compatibility before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the universal design beneficial for inventory management?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Since one FC-TUIO11 can handle multiple types of signals (AI, AO, DI, DO), plants do not need to stock four or five different types of specialized modules, significantly reducing spare parts inventory costs.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518939422893,"sku":"FC-TUIO11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-fc-tuio11-safety-universal-i-o-module-v0ztsxwdjj3.jpg?v=1766982387","url":"https:\/\/www.maxwellplc.com\/products\/fc-tuio11-honeywell-safety-universal-i-o-termination-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}