{"product_id":"fc-tsaoh-0220m-honeywell-safe-analog-output-terminal-block-module","title":"FC-TSAOH-0220M Honeywell Safe Analog Output Terminal Block Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell FC-TSAOH-0220M is a high-integrity Safe Analog Output (SAO) interface engineered for the Experion PKS and Safety Manager environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunctioning as a dual-channel Field Termination Assembly (FTA) module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit facilitates the precise transmission of 4-20mA control signals from C300 controllers to critical final control elements.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is specifically designed for high-availability safety loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering integrated HART communication support which allows for simultaneous analog control and digital field device diagnostics.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts fail-safe architecture ensures that control signals are maintained with extreme accuracy,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it a vital component for SIL 2 rated safety functions where output reliability is non-negotiable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Benchmarks and Engineering Specs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe FC-TSAOH-0220M is characterized by its compact,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eruggedized footprint and advanced electrical protection,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoptimized for deployment in demanding DCS cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Channels\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2 Independent Analog Outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDigital Protocol\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated HART (Highway Addressable Remote Transducer) support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Platform\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell Experion PKS \/ C300 \/ Safety Manager\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Certification\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompliant with SIL 2 standards for safety-critical loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStatic Accuracy\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eExceptional ±0.\u003c\/span\u003e\u003cspan class=\"\"\u003e1% of full-scale output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMaintenance Features\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHot-swappable design for live-system replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtection Circuitry\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in safeguards against overcurrent,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eovervoltage,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand polarity reversal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Mass\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e12 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Profile\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e9.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 x 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA | HS Code 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Control Utility and Deployment\u003c\/h3\u003e\n\u003cp\u003eThis safe analog output module is a cornerstone for process industries that prioritize both precision and functional safety in their automation strategies.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Valve Actuation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivering stable current signals to pneumatic or electric positioners in high-pressure steam or chemical feed lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVFD Speed Management\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegulating variable frequency drives for critical cooling pumps and fans where a signal failure could lead to thermal runaway.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Asset Diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing the HART pass-through capability to perform remote calibration and health checks on submerged or hard-to-reach field actuators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Instrumented Systems (SIS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eServing as the final execution interface for safety loops in oil refineries and petrochemical storage facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Infrastructure Stability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging the modulation of gas turbines or water flow gates in power generation plants, ensuring consistent grid synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518929887405,"sku":"FC-TSAOH-0220M","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-fc-tsaoh-0220m-safe-analog-output-module-fgxsx13tvye.jpg?v=1766982071","url":"https:\/\/www.maxwellplc.com\/products\/fc-tsaoh-0220m-honeywell-safe-analog-output-terminal-block-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}