{"product_id":"eaton-nzmn2-af100-na-molded-case-circuit-breaker-269182-100a-3-pole","title":"Eaton NZMN2-AF100-NA Molded Case Circuit Breaker 269182 100A 3-Pole","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton NZMN2-AF100-NA represents the pinnacle of circuit protection for North American industrial power distribution systems. As a critical component in high-demand environments, this NZM2 frame molded case circuit breaker (MCCB) provides high-level switching capacity and reliable overload protection for feeders and branch circuits. Engineers specifically select the NZM series for its ability to manage heavy electrical loads in demanding machinery and control panels. While standard breakers struggle in high-density industrial settings, the NZMN2-AF100-NA utilizes a specialized thermal-magnetic trip unit to maintain system stability. Its robust 50 kAIC interrupt rating at 480V ensures that the breaker effectively clears high-energy faults, safeguarding your downstream motors, control cabinets, and expensive automation hardware from catastrophic thermal damage.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eGlobal Compatibility \u0026amp; UL Compliance\u003c\/h3\u003e\n\u003cp\u003eThe \"NA\" suffix signifies that this unit meets stringent North American UL 489 standards while maintaining IEC compatibility. This dual-certification allows international OEMs to standardize their panel designs for export to the US and Canadian markets without switching hardware platforms.\u003c\/p\u003e\n\u003ch3\u003ePrecision Short-Circuit Management\u003c\/h3\u003e\n\u003cp\u003eThe adjustable short-circuit release ranges from 600A to 1000A, providing localized control over the magnetic trip threshold. This flexibility allows electrical engineers to fine-tune the protection curve to accommodate high inrush currents from transformers or large motors, preventing nuisance tripping during system startup.\u003c\/p\u003e\n\u003ch3\u003eOptimized NZM2 Frame Design\u003c\/h3\u003e\n\u003cp\u003eEaton's NZM2 architecture balances space-saving compactness with heavy-duty performance. The frame supports a wide array of field-mountable accessories, including remote motor operators and undervoltage releases, allowing the NZMN2-AF100-NA to integrate seamlessly into complex safety interlocking systems and remote-control power grids.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterrupt Rating (480V AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 kAIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e690 V AC \/ 750 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 A (Fixed AF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort-Circuit Adjustment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 - 1000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistribution \/ Feeder Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e105 mm (4.13 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Height\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e184 mm (7.24 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e103 mm (4.05 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.86 kg (4.1 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eTerminal Connection Integrity\u003c\/h3\u003e\n\u003cp\u003eStandard installation requires the use of the front screw terminals. Ensure all conductor connections meet the required torque specifications to prevent high-resistance heating. We recommend inspecting these connections annually with infrared thermography to ensure long-term reliability in high-vibration environments.\u003c\/p\u003e\n\u003ch3\u003eMounting Orientation and Clearance\u003c\/h3\u003e\n\u003cp\u003eThe NZMN2-AF100-NA supports various mounting positions, including vertical and horizontal. However, to maintain the 50 kAIC interrupt rating, you must adhere to the minimum safety clearances specified in the Eaton technical manual. This ensures adequate space for arc gas venting during a major fault event.\u003c\/p\u003e\n\u003ch3\u003eDC Application Wiring\u003c\/h3\u003e\n\u003cp\u003eWhen applying this breaker to a 750V DC circuit, correct polarity and series connection of the poles are mandatory. Failure to follow the DC wiring diagrams will compromise the arc-extinction capabilities of the breaker, potentially leading to equipment failure during a DC fault.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe NZMN2-AF100-NA excels in extreme industrial climates where thermal stability is paramount. The internal components utilize high-grade materials resistant to chemical corrosion and atmospheric aging, ensuring the trip curve remains accurate over years of service. Its seamless compatibility with the Eaton \"Rocker Lever\" and motor drive systems allows for easy manual or automated switching in marshalling cabinets. By choosing this model, procurement managers secure a component with a proven MTBF (Mean Time Between Failure) that exceeds standard commercial alternatives, making it the definitive choice for facilities where operational downtime costs thousands of dollars per hour.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped globally via DHL, FEDEX, or UPS. We utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eheavy-duty, impact-resistant packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand moisture-barrier seals to ensure your MCCB arrives in perfect factory condition, ready for immediate installation.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Does the \"AF\" in the model name mean the overload setting is fixed?\u003c\/p\u003e\n\u003cp\u003eA1: Yes, the AF (Adjustable-Fixed) designation indicates a fixed thermal overload setting of 100A, while providing an adjustable magnetic short-circuit range (600-1000A) to handle varying inrush currents.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I use this breaker for a 600V system in Canada?\u003c\/p\u003e\n\u003cp\u003eA2: Absolutely. The NZMN2-AF100-NA is UL Listed and rated for voltages up to 600V (and 690V IEC), making it fully compliant for industrial use across North America and international sites.\u003c\/p\u003e\n\u003cp\u003eQ3: Is the handle included, or do I need to buy a separate rocker lever?\u003c\/p\u003e\n\u003cp\u003eA3: The standard breaker includes the internal toggle. However, for door-mounted applications or motor-driven control, you will need a separate rotary handle or motor operator accessory.\u003c\/p\u003e\n\u003cp\u003eQ4: What is the difference between NZMN and NZMS series?\u003c\/p\u003e\n\u003cp\u003eA4: The \"N\" in NZMN signifies the \"Normal\" switching capacity (50 kAIC), whereas the \"S\" series typically offers higher interrupt ratings for systems with very high prospective short-circuit currents.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45952998211757,"sku":"NZMN2-AF100-NA","price":59.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NZMN2-AF100-NA_1.jpg?v=1777281640","url":"https:\/\/www.maxwellplc.com\/products\/eaton-nzmn2-af100-na-molded-case-circuit-breaker-269182-100a-3-pole","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}