{"product_id":"e5cc-rx0asm-000-omron-e5cc-series-digital-temperature-controller","title":"E5CC-RX0ASM-000 Omron E5CC Series Digital Temperature Controller","description":"\u003cp\u003eThe \u003cstrong\u003eOmron E5CC-RX0ASM-000\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eE5CC\u003c\/strong\u003e Digital Temperature Controller, operates as a dedicated hardware component for closed-loop thermal regulation and analog process monitoring within industrial panel control loops.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature \u0026amp; Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eE5CC\u003c\/strong\u003e: 48 mm x 48 mm DIN panel-mount temperature controller chassis base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRX\u003c\/strong\u003e: Relay contact control output (250 VAC, 3 A resistive load).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Zero auxiliary alarm relay outputs configured.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Operating supply voltage range of 100 to 240 VAC at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e: Screw terminal block connections provided on rear interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM\u003c\/strong\u003e: Universal analog sensor input interface stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000\u003c\/strong\u003e: Standard feature set without option board expansion modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware \u0026amp; Accuracy Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eE5CC-RX0ASM-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.8 cm x 6.0 cm x 4.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.2 VA max at 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sampling Period\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Accuracy\u003c\/td\u003e\n\u003ctd\u003e(+\/-0.3% of PV or +\/-1 deg C, whichever is greater) +\/-1 digit max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatinum Resistance Thermometer\u003c\/td\u003e\n\u003ctd\u003e(+\/-0.2% of PV or +\/-0.8 deg C, whichever is greater) +\/-1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2% FS +\/-1 digit max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Input Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-5% FS +\/-1 digit max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3% FS max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote SP Input Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2% FS +\/-1 digit max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Speed Signal Processing \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe embedded processing engine executes real-time input sampling at 50 ms intervals to calculate 2-PID parameters and prevent overshoot. Internal non-volatile memory ensures complete firmware flash compatibility during system parameter programming, storing setpoints, input scaling curves, and control response profiles without external battery power. Boot-up memory checks validate register blocks on power initialization, maintaining output relay integrity during AC mains voltage fluctuations.\u003c\/p\u003e\n\u003ch3\u003eProduct Deliverables\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron E5CC-RX0ASM-000 Digital Temperature Controller\u003c\/li\u003e\n\u003cli\u003e1 x Panel Mounting Adapter Kit\u003c\/li\u003e\n\u003cli\u003e1 x Waterproof Front Panel Gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting Requirements \u0026amp; Field Wiring Directives\u003c\/h3\u003e\n\u003ch4\u003ePanel Installation Procedure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCut a 45 mm x 45 mm square opening in the enclosure door; fit the rubber sealing gasket onto the front bezel before insertion to maintain IP66 panel protection.\u003c\/li\u003e\n\u003cli\u003ePush the chassis into the door cutout and push the mounting adapter forward from the rear until the ratchet locks hold the unit firm against the panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Wiring Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect 100 to 240 VAC power and control output circuits to the rear screw terminals using insulated crimp lugs; tighten terminal screws to 0.5 N-m.\u003c\/li\u003e\n\u003cli\u003eLay thermocouple and RTD sensor cables away from high-voltage motor wires, grounding the overall cable shield at a single panel earth point.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat primary control output configuration is provided on the E5CC-RX0ASM-000?\u003c\/p\u003e\n\u003cp\u003eThe RX designation indicates a SPST-NO relay contact output rated for switching up to 250 VAC at 3 A under resistive loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat sampling rate does the internal processor use for analog inputs?\u003c\/p\u003e\n\u003cp\u003eThe controller samples incoming process variables and executes PID calculations at a 50 ms sampling cycle rate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich sensor types are supported by the universal input stage?\u003c\/p\u003e\n\u003cp\u003eThe input circuit accepts standard thermocouples, Pt100\/JPt100 platinum RTDs, linear 4-20 mA current loops, and standard DC voltage signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the E5CC-RX0ASM-000 incorporate auxiliary alarm contacts?\u003c\/p\u003e\n\u003cp\u003eNo, the 0 designation in the model number confirms that no auxiliary alarm relays are installed on this hardware version.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are user setpoints preserved during a main power failure?\u003c\/p\u003e\n\u003cp\u003eInternal EEPROM non-volatile flash memory saves all operating parameter values, calibration constants, and setpoints indefinitely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat display accuracy is achieved when using thermocouple sensors?\u003c\/p\u003e\n\u003cp\u003eThermocouple inputs maintain a measurement accuracy of (+\/-0.3% of PV or +\/-1 deg C, whichever is greater) +\/-1 digit maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat panel cut-out dimensions are required for physical mounting?\u003c\/p\u003e\n\u003cp\u003eThe unit fits standard DIN 48 mm x 48 mm cutouts, requiring a square panel opening measuring 45 mm x 45 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ingress protection level is maintained at the panel door?\u003c\/p\u003e\n\u003cp\u003eWhen installed with the supplied rubber sealing ring, the front panel assembly meets IP66 water-resistant and dust-tight standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306602578093,"sku":"E5CC-RX0ASM-000","price":226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/E5CC-CX3A5M-1_79379b6c-2e06-4001-960a-82c947450bf3.jpg?v=1789997673","url":"https:\/\/www.maxwellplc.com\/products\/e5cc-rx0asm-000-omron-e5cc-series-digital-temperature-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}