{"product_id":"e5cc-cx3a5m-004-omron-e5cc-series-digital-temperature-controller","title":"E5CC-CX3A5M-004 Omron E5CC Series Digital Temperature Controller","description":"\u003cp\u003eThe \u003cstrong\u003eOmron E5CC-CX3A5M-004\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eE5CC\u003c\/strong\u003e Digital Temperature Controller, operates as a dedicated hardware component for closed-loop thermal process evaluation and analog current control execution within Modbus RS-485 network architectures.\u003c\/p\u003e\n\u003ch3\u003eModel Number Decoding \u0026amp; Parameter Index\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eE5CC\u003c\/strong\u003e: Panel-mount enclosure standard (48 x 48 mm panel size DIN 1\/16)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCX\u003c\/strong\u003e: Control Output 1 linear current output (4-20 mA \/ 0-20 mA DC), Control Output 2 none\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e: 3 auxiliary relay alarm outputs (sharing one common terminal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Operating line power voltage rating of 100 to 240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5\u003c\/strong\u003e: Wiring terminal block layout with protective cover and screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM\u003c\/strong\u003e: Universal input processing (thermocouple, RTD, analog DC voltage, or linear DC current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e004\u003c\/strong\u003e: Option configuration set including RS-485 serial communication port and 2 discrete event inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eE5CC-CX3A5M-004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e60 mm x 60 mm x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.2 VA max. (100 to 240 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85% to 110% of rated supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Output\u003c\/td\u003e\n\u003ctd\u003eLinear current output (4-20 mA \/ 0-20 mA DC, load resistance 500 ohm max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Outputs\u003c\/td\u003e\n\u003ctd\u003e3 relay outputs (SPST-NO, 250 VAC, 2 A resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Input Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple, Pt100\/JPt100 RTD, 4-20 mA DC, 0-10 VDC universal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485 (2-wire half-duplex), Modbus-RTU \/ CompoWay\/F protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Inputs\u003c\/td\u003e\n\u003ctd\u003e2 contact \/ NPN open-collector discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Industrial Logic \u0026amp; Communication Integration\u003c\/h3\u003e\n\u003cp\u003eThe controller features high-speed 50-ms sampling cycles to deliver rapid closed-loop response over serial RS-485 multi-drop networks. Interfacing directly with programmable logic controllers via standard industrial communication drivers, the device maintains firmware flash compatibility to preserve control parameter structures across high-density I\/O panel layouts. Isolated output drivers protect internal signal processing microprocessors from ground loop transients across analog field wiring.\u003c\/p\u003e\n\u003ch3\u003eKit Components \u0026amp; Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron E5CC-CX3A5M-004 Digital Process Controller\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Cover Assembly (Pre-mounted)\u003c\/li\u003e\n\u003cli\u003e2 x Panel Mounting Adapter Brackets\u003c\/li\u003e\n\u003cli\u003e1 x Instruction Manual \u0026amp; Panel Cutout Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting \u0026amp; Electrical Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePanel Cutout \u0026amp; Insertion\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrepare a standard 45 x 45 mm square panel cutout. Insert the housing from the front panel and tighten the side mounting brackets until securely seated against the rubber gasket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminal Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect wiring to the rear screw terminals using M3 crimp lugs. Apply a tightening torque between 0.43 and 0.58 N.m to prevent terminal block thread deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Line Shielding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse twisted-pair shielded cables for the RS-485 bus lines. Daisy-chain multiple devices and terminate both ends of the RS-485 network segment with 120-ohm matching resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQs \u0026amp; Engineering Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of primary control output does the E5CC-CX3A5M-004 supply?\u003c\/p\u003e\n\u003cp\u003eThe unit provides a linear DC current output (typically configured for 4-20 mA DC) with a maximum load impedance of 500 ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat communication protocol is supported over the RS-485 port?\u003c\/p\u003e\n\u003cp\u003eThe integrated RS-485 port supports standard Modbus-RTU as well as Omron CompoWay\/F serial communication protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many auxiliary alarm outputs are available on this specific model?\u003c\/p\u003e\n\u003cp\u003eThis model contains 3 auxiliary relay outputs configured with one shared common terminal, rated for 250 VAC at 2 A resistive load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat sensor types can be wired into the universal input terminals?\u003c\/p\u003e\n\u003cp\u003eThe universal input accepts standard thermocouples, Pt100\/JPt100 RTD sensors, 4-20 mA analog signals, and 0-10 V DC voltage inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the two discrete event inputs?\u003c\/p\u003e\n\u003cp\u003eThe two event inputs accept external contact signals to switch set points, start\/stop operation, or trigger auto-tuning modes remotely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the terminal block cover be removed during installation?\u003c\/p\u003e\n\u003cp\u003eYes, the protective terminal cover is removable to facilitate wire crimp lug placement and can be snapped back on for safety compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage range is required to power the controller?\u003c\/p\u003e\n\u003cp\u003eThe unit operates on an AC power feed ranging from 100 to 240 VAC at 50\/60 Hz (allowable range: 85% to 110% rated voltage).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat sampling rate does the internal analog processing circuit maintain?\u003c\/p\u003e\n\u003cp\u003eThe internal sampling period for universal sensor signal processing operates at a fixed 50-ms updating cycle rate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306622959789,"sku":"E5CC-CX3A5M-004","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/E5CC-CX3A5M-1.jpg?v=1789997514","url":"https:\/\/www.maxwellplc.com\/products\/e5cc-cx3a5m-004-omron-e5cc-series-digital-temperature-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}