{"product_id":"e4pa-ls200-m1-n-omron-ultrasonic-displacement-sensor-e4pa","title":"E4PA-LS200-M1-N Omron Ultrasonic Displacement Sensor E4PA","description":"\u003cp\u003eThe \u003cstrong\u003eOmron E4PA-LS200-M1-N\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eE4PA-LS200\u003c\/strong\u003e Ultrasonic Displacement Sensor, operates as a dedicated hardware component for non-contact distance measurement and linear position tracking within automated sensing loops.\u003c\/p\u003e\n\u003ch3\u003eModel Coding Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eE4PA\u003c\/strong\u003e: Ultrasonic displacement sensor series designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLS200\u003c\/strong\u003e: Sensing range specification covering 120 to 2,000 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM1\u003c\/strong\u003e: Standard M12 connector connection interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Updated hardware revision code with mutual interference protection logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Operating Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eE4PA-LS200-M1-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 kg (2 kg Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.6 cm x 11.4 cm x 3.6 cm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C (with no icing or condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1,800 mW max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC (ripple p-p 10% max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Range\u003c\/td\u003e\n\u003ctd\u003e120 to 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDead Band Distance\u003c\/td\u003e\n\u003ctd\u003e0 to 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasonic Frequency\u003c\/td\u003e\n\u003ctd\u003eApprox. 180 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e195 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA (load 500 Ohm max.) \/ 0 to 10 V (load 1,000 Ohm min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e+\/-1% FS max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeat Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% FS max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Module Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe internal analog processing subsystem maintains direct signal integrity when feeding continuous 4-20 mA loops into PLC expansion modules, supporting expanded I\/O density scaling across system architectures. Internal memory parameters and calibration routines preserve ongoing firmware flash compatibility across Sysmac configuration tools.\u003c\/p\u003e\n\u003ch3\u003eBox Packing Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron E4PA-LS200-M1-N Ultrasonic Sensor Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Alignment \u0026amp; Wiring Execution\u003c\/h3\u003e\n\u003ch4\u003eMechanical Mount Configuration\u003c\/h4\u003e\n\u003cp\u003eFix the sensor housing securely using the provided mounting hardware. Angle the sensor face perpendicular to the target surface (100 x 100 mm flat plate benchmark) to ensure maximum acoustic signal reflection.\u003c\/p\u003e\n\u003ch4\u003eCable Connections \u0026amp; Shielding\u003c\/h4\u003e\n\u003cp\u003eRoute 4-wire shielded M12 cable assemblies away from heavy motor leads. Connect the analog loop directly to PLC analog input cards, ensuring allowable load limits (500 Ohm for current, 1,000 Ohm for voltage) are respected.\u003c\/p\u003e\n\u003ch4\u003eAlignment Clearance \u0026amp; Blind Zones\u003c\/h4\u003e\n\u003cp\u003eEnsure no object enters the 0 to 120 mm dead band zone in front of the transducer face. Maintain lateral spatial clearances to avoid acoustic beam reflection off adjacent machine framing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the effective measurement range of the E4PA-LS200-M1-N sensor?\u003c\/p\u003e\n\u003cp\u003eThe sensor evaluates target distance accurately within an operational range from 120 to 2,000 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat dead band zone must be maintained in front of the sensing face?\u003c\/p\u003e\n\u003cp\u003eAn unmeasurable dead band spans from 0 to 120 mm directly in front of the ultrasonic transducer face.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat analog outputs are available on this unit?\u003c\/p\u003e\n\u003cp\u003eThe sensor provides selectable 4 to 20 mA current loop and 0 to 10 V voltage outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operating voltage supply is required to power the device?\u003c\/p\u003e\n\u003cp\u003eThe sensor requires a rated input power supply voltage ranging from 10 to 30 VDC with maximum 10% ripple.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the sensor handle mutual interference when mounted close to adjacent units?\u003c\/p\u003e\n\u003cp\u003eIntegrated mutual interference prevention circuitry operates on a 34 ms cycle time to avoid cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat acoustic operating frequency does the transducer generate?\u003c\/p\u003e\n\u003cp\u003eThe ultrasonic transducer emits acoustic signals at a nominal frequency of approximately 180 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat linear accuracy can be expected across the full measurement scale?\u003c\/p\u003e\n\u003cp\u003eThe linearity error is rated at +\/-1% Full Scale maximum with a repeat accuracy of 0.1% Full Scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does ambient temperature variation affect output values?\u003c\/p\u003e\n\u003cp\u003eOutput values vary within +\/-1% Full Scale of the reading at +23 deg C over the range of -10 to 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306649239725,"sku":"E4PA-LS200-M1-N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/E4PA-LS200-M1-N-1.jpg?v=1790778385","url":"https:\/\/www.maxwellplc.com\/products\/e4pa-ls200-m1-n-omron-ultrasonic-displacement-sensor-e4pa","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}