{"product_id":"ds200tctgg1a-general-electric-mark-v-ds200tctgg1aff-simplex-trip-board","title":"DS200TCTGG1A General Electric Mark V DS200TCTGG1AFF Simplex Trip Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE DS200TCTGG1AFF is a simplex trip board used in legacy Speedtronic turbine control assemblies to implement discrete trip and shutdown interfacing. The board is built around relay-based output switching, allowing the control system to drive trip-related circuits and route contact states through cabinet harnessing. In simplex architectures, this module supports a single-channel trip implementation where relay logic is used for permissives, shutdown paths, and turbine protection interlocks.\u003c\/p\u003e\n\u003cp\u003eThis board is typically installed within a Mark V rack\/cabinet, and it is serviced as a replaceable relay module. Correct replacement requires matching the complete part number and revision to maintain connector pinout and relay allocation.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part number\u003c\/td\u003e\n\u003ctd\u003eDS200TCTGG1AFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule category\u003c\/td\u003e\n\u003ctd\u003eSimplex Trip Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform association\u003c\/td\u003e\n\u003ctd\u003eMark V \/ Speedtronic legacy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput method\u003c\/td\u003e\n\u003ctd\u003eRelay-based discrete trip switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay count\u003c\/td\u003e\n\u003ctd\u003e21 plug-in relays (K1–K21 identifiers commonly used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary connectors\u003c\/td\u003e\n\u003ctd\u003e3 × 50-pin connectors (JLY, JLX, JLZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary connectors\u003c\/td\u003e\n\u003ctd\u003e2 × 12-pin connectors (JN, JM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServiceability\u003c\/td\u003e\n\u003ctd\u003ePlug-in relays retained with metal straps for field replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead time\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (listing)\u003c\/td\u003e\n\u003ctd\u003e28.8 × 7.2 × 3.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin (listing)\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS code (listing)\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem category\u003c\/td\u003e\n\u003ctd\u003eDCS \/ turbine control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance notes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDe-energize the cabinet and follow lockout\/tagout procedures before servicing trip circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocument relay positions and connector locations prior to removal to avoid miswiring during reassembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify relay specifications and contact behavior against the site shutdown logic documentation after replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSimplex turbine trip and shutdown wiring in Mark V control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay output switching for permissive and protective interlocks in gas and steam turbine installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement module for installed-base Speedtronic systems where original relay trip topology is retained\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance programs supporting legacy turbine controls where relay health and contact integrity are critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519084224685,"sku":"DS200TCTGG1AFF","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ds200tctgg1aff-simplex-trip-board-5h3hdmw5ezv.jpg?v=1766986550","url":"https:\/\/www.maxwellplc.com\/products\/ds200tctgg1a-general-electric-mark-v-ds200tctgg1aff-simplex-trip-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}