{"product_id":"ds200tcebg1a-ge-ds200tcebg1ace-protective-termination-expander-board-mark-v-control-system","title":"DS200TCEBG1A GE DS200TCEBG1ACE Protective Termination Expander Board Mark V Control System","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe DS200TCEBG1ACE is a specialized Protective Termination Expander Board developed by General Electric for the Speedtronic Mark V turbine control series.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunctioning as a high-speed emergency trip interface,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis board is an integral safety layer for steam and gas turbine operations.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is specifically designed to manage expansion circuit terminations that require ultra-fast protective responses,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eachieving an execution speed of under 10 milliseconds.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy bridging critical sensor inputs and emergency shutdown logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe DS200TCEBG1ACE ensures that protective sequences are triggered with absolute precision,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esafeguarding expensive rotating machinery from catastrophic failure during transient events or mechanical overspeeds.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eEssential Hardware Features and Environmental Ratings\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis Protective Termination module is built to maintain signal integrity while operating in the rigorous conditions typical of power generation facilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIsolation Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered with a high dielectric strength providing electrical isolation up to 1500 VAC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprotecting the control core from field-side surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResponse Dynamics\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed logic gates allow for emergency trip signal propagation in less than 10ms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Endurance\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRated for continuous operation in extreme temperatures ranging from -40°C to +70°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Efficiency\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConsumes a nominal 8W of power while operating on a standard 24VDC (±10%) industrial supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for 24VDC digital input signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilitating direct connection to protective field contacts and switches.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAtmospheric Resilience\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCapable of functioning in non-condensing humidity levels between 5% and 95% RH.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMechanical Profile\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandardized dimensions of 28 x 21.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 x 2 cm with a total unit weight of 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 kg,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edesigned for efficient mounting within VME-style control racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003ePrimary Industrial Roles and Safety Context\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe DS200TCEBG1ACE serves as a critical node in the turbine's failsafe architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts deployment is centered around high-reliability protection tasks:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Implementation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEmergency Trip Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExecuting the hardware-level \"Stop\" command when turbine parameters exceed safe limits.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCircuit Termination Expansion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProviding additional physical connection points for protective sensors without loading the primary controller board.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTurbine Protective Shell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMonitoring gas and steam turbine parameters to initiate rapid protective shutdowns independently of the main processor.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFailsafe Redundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActing as a localized expander that ensures protective signals are maintained even during DCS network disturbances.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Panel Integration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStreamlining complex wiring for protective relay inputs within the Mark V system enclosure.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519071248557,"sku":"DS200TCEBG1ACE","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ds200tcebg1ace-protective-termination-expander-board-d2jdkdwubuq.jpg?v=1766986222","url":"https:\/\/www.maxwellplc.com\/products\/ds200tcebg1a-ge-ds200tcebg1ace-protective-termination-expander-board-mark-v-control-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}