{"product_id":"ds200shvig1b-general-electric-mark-v-ds200shvig1bgd-scr-high-voltage-board","title":"DS200SHVIG1B General Electric Mark V DS200SHVIG1BGD SCR High Voltage Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE DS200SHVIG1BGD is an SCR high voltage interface board used in legacy GE drive and power conversion assemblies. Its function is to support high-voltage sensing and interface requirements associated with SCR-controlled power sections, helping the control system monitor and manage the power bridge behavior under operating and transient conditions. This module is typically installed inside the drive cabinet in proximity to the SCR bridge and related high-energy wiring, where proper clearances, grounding, and insulation practices are essential.\u003c\/p\u003e\n\u003cp\u003eThis listing text previously referenced a thermocouple termination board, which is not applicable to DS200SHVIG1BGD. The DS200SHVIG1BGD should be treated as a high-voltage interface PCB for SCR applications, and replacement should be verified strictly by part number and cabinet documentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part number\u003c\/td\u003e\n\u003ctd\u003eDS200SHVIG1BGD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule category\u003c\/td\u003e\n\u003ctd\u003eSCR High Voltage Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional role\u003c\/td\u003e\n\u003ctd\u003eHigh-voltage interface\/sensing support for SCR power bridge control (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical installation\u003c\/td\u003e\n\u003ctd\u003eDrive cabinet, near SCR bridge \/ high-energy section (cabinet dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService approach\u003c\/td\u003e\n\u003ctd\u003eReplace as a matched spare by full part number and revision code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandling requirements\u003c\/td\u003e\n\u003ctd\u003eESD precautions and high-voltage safety procedures required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead time\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (listing)\u003c\/td\u003e\n\u003ctd\u003e18.8 × 14.2 × 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin (listing)\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS code (listing)\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem category\u003c\/td\u003e\n\u003ctd\u003eDCS \/ drive control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSafety and commissioning notes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDe-energize and discharge DC bus circuits before touching any cabinet hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect insulation barriers, standoffs, and connector condition during replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform post-installation verification per site procedures (HV sensing checks and fault-free startup)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGE drive systems using SCR bridges where high-voltage interface feedback is required for regulation and protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of aging high-voltage interface boards to address nuisance faults, unstable sensing, or startup lockouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstalled-base maintenance of legacy GE power conversion cabinets in industrial plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService support for turbine auxiliary drives and other SCR-controlled equipment where original cabinet design is retained\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519084322989,"sku":"DS200SHVIG1BGD","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ds200shvig1bgd-scr-high-voltage-board-3f2thrrxa2p.jpg?v=1769670163","url":"https:\/\/www.maxwellplc.com\/products\/ds200shvig1b-general-electric-mark-v-ds200shvig1bgd-scr-high-voltage-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}