{"product_id":"cv-opcuda-honeywell-opc-ua-da-server-client-license","title":"CV-OPCUDA Honeywell OPC UA DA Server Client License","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CV-OPCUDA is a specialized software enablement license designed to activate OPC UA Data Access (DA) server capabilities within the PlantCruise and Experion LX automation environments. Functioning as a secure communication gateway, this license allows the Distributed Control System (DCS) to export real-time process variables, alarms, and historical trends to external client applications. Unlike generic drivers, the CV-OPCUDA is architected on a \"per-client\" basis, allowing organizations to scale their data integration strategy based on the specific number of Client Application Instances (CAIs) connected to the plant network. This module is a fundamental requirement for facilities bridging the gap between Operational Technology (OT) and enterprise-level Information Technology (IT) infrastructures.\u003c\/p\u003e\n\u003ch3\u003eArchitecture Performance and Integration Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOPC UA Data Access (DA) for secure, encrypted telemetry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLicensing Model:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePer Client Application Instance (CAI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlantCruise R500 (or later) and Experion LX platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Prerequisites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires CV-BATCHMGR base and SQL Server 2019 (or compatible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Compute Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuad-core processor, minimum 2.0 GHz clock speed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Allocation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e150 MB of RAM recommended per 1,000 tags exposed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEncryption Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports modern X.509 certificate-based authentication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 x 14 x 14.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHS Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnterprise Connectivity and Strategic Utilization\u003c\/h3\u003e\n\u003cp\u003eIn the era of Industry 4.0, the CV-OPCUDA acts as the primary data conduit for advanced manufacturing plants, refineries, and pharmaceutical labs. By deploying this server license, operators can securely feed live process data into Manufacturing Execution Systems (MES), Enterprise Resource Planning (ERP) software, and specialized cloud-based analytics platforms. Its \"per-client\" structure is particularly advantageous for decentralized operations, where multiple third-party tools—such as remote monitoring dashboards or predictive maintenance AI—require independent, concurrent streams of information. By standardizing on the OPC UA protocol, the CV-OPCUDA eliminates the vulnerabilities associated with legacy DCOM-based OPC Classic, providing a firewall-friendly and platform-independent solution for global data interoperability.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What exactly does \"per client\" licensing mean for the CV-OPCUDA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Each CV-OPCUDA license entitles one external application instance to connect to the PlantCruise OPC UA server. If you have three separate systems (e.g., an ERP, an MES, and a remote HMI) connecting simultaneously, you would typically require three client licenses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CV-OPCUDA compatible with older versions of PlantCruise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This specific license is validated for PlantCruise R500 and subsequent releases. Systems running earlier versions may require an upgrade to the software baseline and a compatible SQL Server environment to support the OPC UA framework.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does this license handle data security?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Unlike legacy OPC, the CV-OPCUDA utilizes the native security features of the OPC UA standard, including digital signatures and 128-bit or 256-bit encryption, ensuring that process data cannot be intercepted or spoofed by unauthorized actors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does adding more tags to the server slow down the DCS controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The server typically resides on a dedicated station or the primary server hardware, not the controller itself. While it consumes server RAM (approx. 150MB per 1k points), it is designed to minimize any impact on real-time control execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CV-BATCHMGR license strictly necessary?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, in the PlantCruise architecture, the OPC UA server functionality leverages specific database structures provided by the Batch Manager license, which must be active on the system for the CV-OPCUDA to function correctly.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518939881645,"sku":"CV-OPCUDA","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cv-opcuda-opc-ua-da-server-per-client-us5xjyt3cmh.jpg?v=1766982408","url":"https:\/\/www.maxwellplc.com\/products\/cv-opcuda-honeywell-opc-ua-da-server-client-license","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}