{"product_id":"cv-opcint-honeywell-opc-integrator-sai-3-interface-module","title":"CV-OPCINT Honeywell OPC Integrator SAI 3 Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CV-OPCINT is a high-performance communication gateway designed specifically for the PlantCruise and Experion LX automation environments. Functioning as an OPC Integrator SAI 3, this module serves as the primary bridge for bidirectional data flow between the Distributed Control System (DCS) and external third-party software applications. By adhering to IEC 61131-3 standards and utilizing specialized Library Version 2.4, the CV-OPCINT ensures that real-time process data is normalized and accessible for enterprise-level systems. This module is essential for facilities requiring high-speed data integration without compromising the security or deterministic nature of the core control network.\u003c\/p\u003e\n\u003ch3\u003ePerformance Benchmarks and Hardware Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExecution Velocity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcessing cycle times as low as ≤5ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compliant with IEC 61131-3 logic protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports 32-bit floating-point mathematical calculations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracks up to 512 individual harmonics simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated I\/O Scalability:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e64 Analog Inputs \/ 32 Analog Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e128 Digital Inputs \/ 64 Digital Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e256 User-configurable software alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLibrary Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with Library Version 2.4 (2023 release)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 x 14 x 14.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHS Tariff Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Interoperability and Application Scope\u003c\/h3\u003e\n\u003cp\u003eThe CV-OPCINT is primarily deployed in medium-to-large scale industrial facilities that rely on seamless communication between Operational Technology (OT) and Information Technology (IT) layers. It is the preferred solution for connecting Honeywell PlantCruise systems to Manufacturing Execution Systems (MES), ERP platforms, or custom laboratory information management systems (LIMS). Its ability to monitor complex harmonic data makes it highly valuable in power quality management and heavy motor control applications. By facilitating a transparent data exchange at a 100ms configurable execution rate, this integrator supports Industry 4.0 initiatives, enabling advanced data analytics, centralized remote monitoring, and plant-wide optimization strategies that drive digital transformation.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main advantage of the SAI 3 version over standard OPC interfaces?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The SAI 3 (System Access Interface) designation indicates a deeper level of integration with the Honeywell PlantCruise environment, providing faster execution times (≤5ms) and better handling of complex I\/O counts compared to generic software-only OPC drivers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CV-OPCINT require a specific software library to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, this module is optimized for use with Library Version 2.4 (2023). Using the correct library ensures that all 512 harmonic monitoring points and the 256 alarm configurations are fully supported by the system firmware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module communicate with non-Honeywell PLCs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the CV-OPCINT is a Honeywell hardware module, its primary purpose is to act as an OPC server\/client, meaning it can exchange data with any third-party device or application that follows standard OPC protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the 32-bit floating-point math benefit my process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 32-bit precision allows for highly accurate scaling of analog signals. This is critical for processes involving precise chemical dosing, custody transfer, or complex heat balance calculations where rounding errors could impact quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module suitable for high-speed power monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. With the ability to monitor 512 harmonics and a rapid execution rate, the CV-OPCINT is frequently used in electrical substations and power-intensive industrial plants to track power quality and equipment health.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518940340397,"sku":"CV-OPCINT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cv-opcint-opc-integrator-sai-3-k3ekzkbxn1j.jpg?v=1766982425","url":"https:\/\/www.maxwellplc.com\/products\/cv-opcint-honeywell-opc-integrator-sai-3-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}