{"product_id":"cpm810-abb-advant-ocs-800xa-common-processor-module","title":"CPM810 ABB Advant OCS 800xA Common Processor Module","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eConfigured for controller processing and system communication execution in ABB Advant OCS and 800xA control platforms, the \u003cstrong\u003eABB CPM810\u003c\/strong\u003e (\u003cstrong\u003eCPM810\u003c\/strong\u003e Common Processor Module) provides processor-level computation and memory management functions for distributed control applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eModule Identification\u003c\/h3\u003e\n\u003cp\u003eThe ABB CPM810 is a Common Processor Module designed for Advant OCS\/800xA control systems. The module integrates a 32-bit RISC-based processor, flash memory, and SDRAM resources for execution of control application tasks and system services.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCPM810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommon Processor Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAdvant OCS \/ 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 x 10.6 x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C standard; -25 deg C to +70 deg C extended with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 8 W, maximum 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC-based microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Speed\u003c\/td\u003e\n\u003ctd\u003e40 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e32 MB SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eIndustrial Control Processing Features\u003c\/h3\u003e\n\u003cp\u003eThe CPM810 operates as a processor node within ABB Advant OCS and 800xA architectures. The module executes application logic, system management functions, and communication handling between control components.\u003c\/p\u003e\n\u003cp\u003eABB control platforms use deterministic internal communication structures for controller and I\/O coordination. The CPM810 processor resources support system task execution, while memory allocation depends on configured applications, databases, and installed control functions.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility must be verified when replacing CPM810 modules in existing Advant control installations. System software revision matching is required to maintain communication and application execution.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB CPM810 Common Processor Module\u003c\/li\u003e\n\u003cli\u003eCompatible installation requires an ABB Advant OCS or 800xA controller rack configuration\u003c\/li\u003e\n\u003cli\u003eSystem configuration data and application software are managed through the installed control system environment\u003c\/li\u003e\n\u003cli\u003eAdditional controller accessories depend on the specific rack and system architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CPM810 module in the designated ABB controller rack position.\u003c\/li\u003e\n\u003cli\u003eConfirm rack power is isolated before module insertion or removal.\u003c\/li\u003e\n\u003cli\u003eVerify module locking mechanism engagement after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Connection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse the specified 5 V DC system power supply.\u003c\/li\u003e\n\u003cli\u003eCheck rack power distribution before commissioning.\u003c\/li\u003e\n\u003cli\u003eAvoid installation near high electromagnetic interference sources.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMaintenance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm firmware compatibility before replacing existing processor modules.\u003c\/li\u003e\n\u003cli\u003eProtect memory components from electrostatic discharge during handling.\u003c\/li\u003e\n\u003cli\u003eVerify controller communication status after module replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat processor is used in the CPM810?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPM810 uses a 32-bit RISC-based microprocessor operating at a 40 MHz clock frequency for control processing tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich ABB systems support the CPM810?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPM810 is designed for ABB Advant OCS and 800xA control system environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating voltage of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module operates from a 5 V DC power supply provided by the controller rack system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow much memory is available in the CPM810?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module contains 64 MB flash memory and 32 MB SDRAM for application and system data storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CPM810 support direct field I\/O wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CPM810 is a processor module and communicates with field I\/O through the configured ABB control architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CPM810 be installed in any ABB rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Installation depends on compatibility with the specified Advant OCS or 800xA controller hardware configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat environmental conditions apply to the CPM810?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard operation is specified from 0 deg C to +55 deg C, with extended operation from -25 deg C to +70 deg C under derating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes replacing the CPM810 require firmware verification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Firmware and system software compatibility should be checked before replacing the processor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021150376109,"sku":"CPM810","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_cpm810_2.jpg?v=1786071859","url":"https:\/\/www.maxwellplc.com\/products\/cpm810-abb-advant-ocs-800xa-common-processor-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}