{"product_id":"cp1w-ts004-omron-cp1w-series-analog-input-module","title":"CP1W-TS004 Omron CP1W Series Analog Input Module","description":"\u003cp\u003eConfigured for analog temperature input digitization in Omron CP1 PLC systems, the \u003cb\u003eOmron CP1W-TS004\u003c\/b\u003e (\u003cb\u003eCP1W\u003c\/b\u003e I\/O Expansion Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModule Designation \u0026amp; Model Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCP1W\u003c\/b\u003e: Expansion unit series for CP1 series compact programmable controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTS\u003c\/b\u003e: Temperature sensor input module functional designation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e004\u003c\/b\u003e: Model iteration code specifying 12-bit conversion resolution across 2 discrete analog input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCP1W-TS004\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.380 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 cm x 10.0 cm x 8.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 W max (supplied via CPU expansion bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog I\/O Expansion Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 cm x 15 cm x 9 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Integration \u0026amp; Deterministic Scaling\u003c\/h3\u003e\n\u003cp\u003eThe expansion module interfaces directly to the PLC CPU backplane bus cable to enable low-latency signal acquisition. Optimized internal bus protocols preserve high backplane bus communication velocity while maintaining CPU firmware flash compatibility and predictable I\/O density scaling across expanded multi-module configurations.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Omron CP1W-TS004 Expansion Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bus Extension Connecting Cable Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Terminal Connector Cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDIN-Rail Mounting\u003c\/b\u003e: Mount the expansion block onto a standard 35 mm DIN rail adjacent to the CPU unit. Engage the rear mounting clip until an audible latching sound confirms physical security.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBus Connection Procedure\u003c\/b\u003e: Connect the expansion ribbon cable directly into the expansion port of the preceding CPU or expansion module prior to applying system power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSignal Shielding\u003c\/b\u003e: Ground all sensor wire shielding at a single point to prevent electrical noise interference from corrupting 12-bit analog input conversion values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the required procedure for connecting the unit to the CPU backplane?\u003c\/p\u003e\n\u003cp\u003ePower off the main CPU unit completely before plugging the integrated expansion ribbon connector into the adjacent CPU bus port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping allowed for this expansion unit while the PLC is powered?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swapping is strictly prohibited; removing or attaching expansion units under power will result in backplane fault errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the CPU supply power to the expansion module?\u003c\/p\u003e\n\u003cp\u003eOperating power is drawn directly from the main CPU base unit via the ribbon expansion interconnect cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat digital resolution does the unit provide for input processing?\u003c\/p\u003e\n\u003cp\u003eThe onboard analog-to-digital converter processes physical input signals into 12-bit digital values across both input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many total analog channels are supported by a single unit?\u003c\/p\u003e\n\u003cp\u003eThe module provides 2 dedicated, independent analog input channels for sensor signal digitization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat action should be taken if an I\/O bus error occurs on the module?\u003c\/p\u003e\n\u003cp\u003eVerify physical alignment of the expansion cable, clean edge connector contacts, and power cycle the host PLC controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat gauge wiring is recommended for the terminal block connections?\u003c\/p\u003e\n\u003cp\u003eUse twisted-pair copper conductors ranging from 0.5 mm sq to 1.25 mm sq to ensure reliable terminal clamping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan multiple CP1W expansion modules be daisy-chained together?\u003c\/p\u003e\n\u003cp\u003eYes, modules attach sequentially up to the maximum expansion limit defined by the host CPU model specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306634166445,"sku":"CP1W-TS004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_cp1e-cp1w-ts004.jpg?v=1788590702","url":"https:\/\/www.maxwellplc.com\/products\/cp1w-ts004-omron-cp1w-series-analog-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}