{"product_id":"cio-100-phbcio10010000-abb-infi-90-input-module","title":"CIO-100 PHBCIO10010000 ABB Infi 90 Input Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB PHBCIO10010000\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCIO-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC Input Module, operates as a dedicated hardware component for analog signal acquisition and control block execution within ABB Infi 90 automation architectures. The module provides four non-isolated analog input channels and two non-isolated analog output channels while interfacing with the system backplane through an isolated field-to-bus connection rated at 2500 Vrms.\u003c\/p\u003e\n\u003ch3\u003eModule Identification\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies this product as a fixed hardware configuration:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCIO-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Part Number\u003c\/td\u003e\n\u003ctd\u003ePHBCIO10010000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC Input Module \/ Control Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eABB Infi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCIO-100 \/ PHBCIO10010000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Description\u003c\/td\u003e\n\u003ctd\u003eControl Block CIO-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.6 x 20.3 x 27.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4, non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2, non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e+5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.75 W (typical, based on 5 VDC x 350 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-to-Bus Isolation\u003c\/td\u003e\n\u003ctd\u003e2500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 % to 95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Origin\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Communication and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eWithin ABB Infi 90 installations, the CIO-100 participates in backplane-based communication between field I\/O resources and the controller environment. The module combines four analog input channels and two analog output channels in a single assembly, allowing localized signal acquisition and output handling while maintaining electrical separation between field wiring and the system bus through the specified 2500 Vrms isolation barrier. Compatibility with the installed controller firmware and rack configuration should be verified before commissioning or replacement activities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Questions and Answers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module provide isolation on individual analog channels?\u003c\/strong\u003e\u003cbr\u003eA: The specified analog inputs and analog outputs are identified as non-isolated channels. Field-to-bus isolation is provided at 2500 Vrms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power source is required for operation?\u003c\/strong\u003e\u003cbr\u003eA: The module requires a +5 VDC supply and draws approximately 350 mA from the backplane or system power source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be installed in environments below freezing temperature?\u003c\/strong\u003e\u003cbr\u003eA: Operation is specified from 0 deg C to +70 deg C. Storage is permitted from -40 deg C to +85 deg C when the module is not energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What signal capacity is available on the module?\u003c\/strong\u003e\u003cbr\u003eA: The module supports four analog input channels and two analog output channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are special grounding practices recommended during installation?\u003c\/strong\u003e\u003cbr\u003eA: Shield termination, cabinet grounding, and separation of signal and power conductors should follow site electrical standards and ABB system installation practices.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Recommendations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify rack slot assignment and controller configuration before inserting the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemove system power when installation procedures require backplane access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute analog signal wiring separately from high-voltage and motor power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate cable shields according to plant grounding philosophy to minimize induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm field-to-bus isolation integrity and terminal tightness during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect connectors and backplane contacts for contamination or mechanical damage before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain cabinet temperature and humidity within specified operating limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord module serial number and installation location for maintenance traceability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePackage contents typically include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB CIO-100 PLC Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x PHBCIO10010000 spare part assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory identification labels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective anti-static packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional accessories and system-specific mounting hardware should be selected according to the installed ABB Infi 90 rack configuration.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Packaging\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipment available through DHL, FedEx, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePacked using anti-static industrial packaging materials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective cushioning applied for long-distance international transportation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExport packaging suitable for warehouse storage and transit handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021143396525,"sku":"PHBCIo10010000","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/PHBCIo10010000-1.jpg?v=1780212825","url":"https:\/\/www.maxwellplc.com\/products\/cio-100-phbcio10010000-abb-infi-90-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}