{"product_id":"cc-tpix11-honeywell-experion-redundant-pulse-input-module-8-channel","title":"CC-TPIX11 Honeywell Experion Redundant Pulse Input Module 8-Channel","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe CC-TPIX11 is a pulse input I\/O module used in Honeywell Experion PKS C300 \/ Series C architectures for acquiring high-speed pulse and frequency signals from field devices. It is designed for applications where pulse measurement accuracy and signal integrity are required, including flow pulse pickup, rotational speed sensing, and metering systems. The module supports flexible channel configuration, allowing it to be set up as eight independent pulse inputs for maximum frequency capability or as four dual-input channels for quadrature (A\/B) encoder measurements.\u003c\/p\u003e\n\u003cp\u003eElectrical isolation and differential input design help protect the control system from ground potential differences and transient disturbances, improving reliability in electrically noisy plant environments. The module also supports common pulse-processing functions used by control and measurement strategies, such as frequency and period measurement and totalization.\u003c\/p\u003e\n\u003ch3\u003eSignal and Electrical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eChannel configuration options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 single pulse input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e4 dual-pulse channels for quadrature encoder applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMixed configuration support depending on project requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency range: 0 to 100 kHz in single-channel mode (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency accuracy: ±0.001% (typical, application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eInput design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-impedance differential pulse inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelectable edge detection (rising or falling)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable input threshold\/trip levels to match sensor output characteristics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOptical isolation rated to 1000 VDC (typical) for improved noise immunity and ground-loop reduction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003ePower\/excitation support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports internal 24 VDC supply usage and external excitation options (typical 5 to 30 VDC depending on wiring design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOutput functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes output channels for driving external indication or alarm devices (implementation dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003ePulse Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003eCC-TPIX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem family\u003c\/td\u003e\n\u003ctd\u003eExperion PKS C300 \/ Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e~0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (approx.)\u003c\/td\u003e\n\u003ctd\u003e7.0 x 14.0 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePulse-output flowmeter signal acquisition for flow measurement and totalization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine and rotating equipment speed monitoring using magnetic pickups or pulse sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas measurement skids and metering stations using high-frequency pulse streams\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuadrature encoder monitoring for position\/speed applications using dual-channel A\/B signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical process loops that require redundant I\/O behavior to reduce measurement interruption risk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518952562861,"sku":"CC-TPIX11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cc-tpix11-pulse-input-module-dfmmdkh2hsm.jpg?v=1766982815","url":"https:\/\/www.maxwellplc.com\/products\/cc-tpix11-honeywell-experion-redundant-pulse-input-module-8-channel","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}