{"product_id":"cc-gdil11-honeywell-fsc-system-32-channel-24vdc-digital-input-module","title":"CC-GDIL11 Honeywell FSC System 32-Channel 24VDC Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe CC-GDIL11 is a 32-point digital input module used in Honeywell FSC System architectures for acquiring 24 VDC discrete field signals with high integrity. It is designed for applications that require dependable state detection, electrical separation between field wiring and control electronics, and diagnostic capability suitable for safety and critical control environments.\u003c\/p\u003e\n\u003cp\u003eThis module is typically paired with compatible intrinsic safety\/galvanic isolators (such as MTL45xx series devices) when signals originate from hazardous-area circuits. The design supports clear status representation and event capture options for time-sensitive discrete input monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput capacity: 32 digital inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal type: 24 VDC discrete inputs (dry contact or powered discrete, depending on wiring\/isolator design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: Galvanic isolation via compatible isolator interface practices to separate field and system domains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolator compatibility: Commonly used with MTL45xx series isolators, including variants with line fault detection and phase reversal diagnostics (model dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eScan\/event performance modes (application dependent):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eStandard monitoring with typical 20 ms update rate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSequence of Events capture with 1 ms time-stamp resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-latency monitoring with typical 5 ms scan behavior\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics and integrity features:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOpen-wire detection support in standard monitoring mode (wiring\/isolator dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal self-checks for module health and data validity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable direct\/reverse input state indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003eCC-GDIL11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem family\u003c\/td\u003e\n\u003ctd\u003eFSC System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e~0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (approx.)\u003c\/td\u003e\n\u003ctd\u003e7.0 x 14.0 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e24 VDC discrete status monitoring in safety and critical control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous-area discrete input acquisition using galvanic isolators and line-fault diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSequence-of-events recording for trips, permissives, interlocks, and plant upset analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed discrete monitoring where reduced latency improves response or event visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas, chemical, and power generation facilities requiring robust DI integrity and maintainable diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518952595629,"sku":"CC-GDIL11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cc-gdil11-digital-input-module-5wdvlhzugp3.jpg?v=1766982819","url":"https:\/\/www.maxwellplc.com\/products\/cc-gdil11-honeywell-fsc-system-32-channel-24vdc-digital-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}