{"product_id":"cc-gaox21-honeywell-fsc-system-gi-is-16-channel-4-20ma-analog-output-module","title":"CC-GAOX21 Honeywell FSC System GI\/IS 16-Channel 4–20mA Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe CC-GAOX21 is a GI\/IS analog output module used in Honeywell FSC System environments to drive current-loop control signals to field devices. It provides 16 independent 4–20 mA output channels for valves, positioners, I\/P converters, and recording instruments that require stable analog command signals. The module is typically applied in cabinet builds where a compact, non-redundant analog output solution is acceptable and where wiring fault detection and output verification are required for maintenance integrity.\u003c\/p\u003e\n\u003cp\u003eIn addition to generating output current, the CC-GAOX21 supports output readback and diagnostic functions that help confirm the commanded signal is being delivered as expected. Channel-level response behavior can be configured to match the site’s safety and operational philosophy when abnormal conditions occur.\u003c\/p\u003e\n\u003ch3\u003eOutput Performance and Electrical Characteristics\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eTypical Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput type\u003c\/td\u003e\n\u003ctd\u003e4–20 mA current outputs (per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel count\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput set range\u003c\/td\u003e\n\u003ctd\u003e0 to 21.1 mA (typical configurable span)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad capability\u003c\/td\u003e\n\u003ctd\u003eUp to 800 Ω with 24 V supply (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple\/noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\/resolution\u003c\/td\u003e\n\u003ctd\u003e±0.05% of full scale (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.35% (typical at standard conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature drift\u003c\/td\u003e\n\u003ctd\u003e0.005% of full scale per °C (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOpen-wire detection, channel soft failure indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVerification\u003c\/td\u003e\n\u003ctd\u003eOutput read-back monitoring with alarm on deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFail response\u003c\/td\u003e\n\u003ctd\u003ePer-channel FAILOPT behavior (hold last value or drive to predefined safe value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAdditional integration notes\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOften used with GI\/IS IOTA-style mounting and Honeywell cabinet wiring practices (exact carrier\/base depends on FSC build)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHART-related functionality may be supported depending on system configuration; verify HART use case requirements with the project hardware definition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog control of modulating valves, dampers, and actuators using 4–20 mA commands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput signaling for I\/P converters, VFD analog references, and chart\/recorder inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess units requiring fault indication for open-loop wiring conditions on analog outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety and critical control cabinets where defined fail behavior (hold or safe value) is required per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical, refining, and power generation plants needing stable multi-channel analog output in a compact module format\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518950367405,"sku":"CC-GAOX21","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cc-gaox21-gi-is-analog-output-faacg2zwokb.jpg?v=1766982728","url":"https:\/\/www.maxwellplc.com\/products\/cc-gaox21-honeywell-fsc-system-gi-is-16-channel-4-20ma-analog-output-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}