{"product_id":"bently-nevada-991-01-xx-01-01-thrust-transmitter-284318-01","title":"Bently Nevada 991-01-XX-01-01 Thrust Transmitter 284318-01","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 991 Thrust Transmitter represents the gold standard for monitoring axial displacement in critical rotating machinery. By converting complex proximity probe signals into a standardized 4-20mA output, this transmitter enables direct integration into existing DCS, PLC, or SCADA control loops. Engineers rely on this device to detect rotor drift, bearing wear, and potential catastrophic failure before they escalate into unplanned downtime. Designed for reliability, it ensures high-accuracy monitoring of shaft position relative to the bearing housing, providing the essential data required for automated emergency shutdown systems. Its compact, ruggedized architecture thrives in the demanding conditions of oil and gas refineries, power generation plants, and heavy manufacturing facilities where precision is non-negotiable.\u003c\/p\u003e\n\u003ch2\u003eConfiguration Intelligence\u003c\/h2\u003e\n\u003cp\u003eThe 991-01-XX-01-01 model structure employs specific suffixes to dictate system performance and safety parameters.\u003c\/p\u003e\n\u003cp\u003eThe initial 01 prefix signifies the fundamental thrust transmitter category designed for axial position monitoring.\u003c\/p\u003e\n\u003cp\u003eThe XX placeholder allows for flexible cable length selection (typically 5.0 or 7.0 meters), ensuring compatibility with varied site-specific sensor-to-transmitter distances.\u003c\/p\u003e\n\u003cp\u003eThe 01 DIN-rail clip option provides rapid, secure mounting within standard industrial control cabinets, facilitating dense instrumentation layouts.\u003c\/p\u003e\n\u003cp\u003eThe final 01 suffix confirms CSA Division 2 hazardous area certification, guaranteeing safe operation in environments where flammable gases or vapors may occasionally be present.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.3 x 5.0 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eIndustrial Grade Engineered Polymer\/Metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18-30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of reading or +\/- 25µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eImplementation Best Practices\u003c\/h2\u003e\n\u003cp\u003eEffective monitoring starts with correct probe-to-target gap calibration. Ensure the proximity probe is gapped according to the manufacturer’s specifications to maintain the transmitter’s linear response range. When routing cables, maintain separation from high-voltage AC lines to prevent induced noise on the 4-20mA signal path. If installing in a Division 2 area, verify that all conduit connections meet local code requirements for hazardous location integrity. Utilize the built-in DIN-rail mounting clips for a solid ground connection back to the panel chassis, which significantly improves common-mode noise rejection.\u003c\/p\u003e\n\u003ch2\u003eOperational Versatility\u003c\/h2\u003e\n\u003cp\u003eThis transmitter excels in harsh industrial environments by leveraging advanced signal conditioning technology. It remains unfazed by extreme temperature fluctuations, maintaining stability in both arctic and tropical climates. The seamless integration with Turbine Supervisory Instrumentation (TSI) suites ensures that axial position data is accurately relayed to control operators. Its low power consumption and high-resolution output make it an ideal choice for legacy system upgrades, providing a cost-effective path to modernizing machinery protection without the need for a complete control system overhaul.\u003c\/p\u003e\n\u003ch2\u003eProcurement Logistics\u003c\/h2\u003e\n\u003cp\u003e(1) Shipment contains one original Bently Nevada 991-01-XX-01-01 Thrust Transmitter.\u003c\/p\u003e\n\u003cp\u003e(2) Unit arrives in factory-sealed, static-shielded packaging.\u003c\/p\u003e\n\u003cp\u003e(3) Installation hardware includes factory-fitted 35mm DIN-rail clips.\u003c\/p\u003e\n\u003cp\u003e(4) Certificates of conformance and technical documentation are included for audit compliance.\u003c\/p\u003e\n\u003ch2\u003eTechnical Inquiries\u003c\/h2\u003e\n\u003cp\u003eQ1: What does the 284318-01 MOD number represent?\u003c\/p\u003e\n\u003cp\u003eA1: The 284318-01 identifies the specific hardware revision and build standard for this 991 series transmitter.\u003c\/p\u003e\n\u003cp\u003eQ2: Can this transmitter work with non-Bently probes?\u003c\/p\u003e\n\u003cp\u003eA2: For maximum accuracy and system reliability, we strongly recommend pairing this transmitter only with authorized Bently Nevada proximity probe systems.\u003c\/p\u003e\n\u003cp\u003eQ3: Is the 4-20mA output isolated?\u003c\/p\u003e\n\u003cp\u003eA3: The output is designed to provide a robust, interference-resistant signal suitable for long cable runs to your PLC or DCS.\u003c\/p\u003e\n\u003cp\u003eQ4: What is the benefit of the 5.0m or 7.0m cable option?\u003c\/p\u003e\n\u003cp\u003eA4: Choosing the correct cable length minimizes signal degradation and eliminates the need for excess cable coiling, which can introduce parasitic inductance.\u003c\/p\u003e\n\u003cp\u003eQ5: How do I handle payment and shipping?\u003c\/p\u003e\n\u003cp\u003eA5: We facilitate secure wire transfers for all international orders; shipment tracking and pro-forma documentation are provided upon payment confirmation.\u003c\/p\u003e\n\u003cp\u003eQ6: Does this unit require external calibration?\u003c\/p\u003e\n\u003cp\u003eA6: The device is factory-calibrated; however, we recommend a routine verification check during the initial site commissioning process.\u003c\/p\u003e\n\u003cp\u003eQ7: What is the primary cause of signal drift in this transmitter?\u003c\/p\u003e\n\u003cp\u003eA7: Signal drift is typically caused by improper grounding, cable damage, or changes in the probe-to-shaft air gap due to thermal expansion.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026756554925,"sku":"991-01-XX-01-01 MOD:284318-01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/Bently991-50-XX-01-00_10_5_999a1a87-15a2-488b-9619-25bcbe15f4f5.jpg?v=1783993319","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-991-01-xx-01-01-thrust-transmitter-284318-01","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}