{"product_id":"bently-nevada-990-04-70-02-00-990-series-vibration-transmitter","title":"Bently Nevada 990-04-70-02-00 990 Series Vibration Transmitter","description":"\u003cp\u003eConfigured for fluid-film bearing displacement monitoring and machinery protection loops, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-04-70-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e990\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVibration Transmitter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Code Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 0-4 mils pp (0-100 um pp) full-scale range option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e70\u003c\/strong\u003e: 7.0 meters (23.0 feet) integrated proximity transducer system length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Bulkhead screws mounting mechanical configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Not required agency approval path\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransmitter Hardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e990-04-70-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.44 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 x 7.3 x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +85 deg C (standard transmitter window)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 1.0 Watt maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-4 mils peak-to-peak (0-100 um peak-to-peak)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 meters (23.0 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBulkhead installation via machine screws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA DC proportional to vibration amplitude\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProximity Sensor Interface and Calibration\u003c\/h3\u003e\n\u003cp\u003eThe internal electronics execute highly stable eddy-current probe scaling, matching the electrical impedance of a 7.0-meter proximity transducer configuration. The device converts proximity voltage changes into a linear 4-20 mA current output loop for direct DCS or PLC integration. Crucial calibration sequences rely on accurate gap voltage validation, targeting standard negative DC voltage baselines (such as -10 VDC centers) to secure continuous measurement symmetry. By maintaining strict voltage linearity across the designated full-scale span, the electronic circuit preserves dynamic rotor dynamics resolution while employing internal filters for cross-talk suppression between adjacent sensor channels.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Inclusions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e990-04-70-02-00 vibration transmitter base unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThreaded bulkhead mounting screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory inspection calibration report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect termination terminal block headers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mount and Signal Grounding\u003c\/h3\u003e\n\u003cp\u003eMount the transmitter housing onto a rigid, low-vibration flat bulkhead surface using the supplied machine screws. Avoid routing the unshielded transducer extension line or the 4-20 mA loop wires inside common cable trays housing three-phase AC motor feeds or high-draw switching power cabling to insulate the loop from inductive fields. Ensure the external cable shield layer grounds exclusively at one location, typically terminating directly at the control console terminal strip. The sensor extension cable connections must be clean, dry, and securely wrapped with self-mating insulating tape to eliminate low-impedance ground faults from fluid entry.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Packaging Protocols\u003c\/h3\u003e\n\u003cp\u003eStandard logistics processing handles shipments within 2-7 days when payment finish parameters are updated. Dispatch originates from Xiamen, China, routing through international air carriers including DHL, FEDEX, and UPS. All delicate proximity signal conditioning modules are packed inside multi-layered anti-static industrial packaging to prevent degradation from electrostatic fields and mechanical impact during global transit.\u003c\/p\u003e\n\u003ch3\u003eSensor Troubleshooting and Operational FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: How affects a mismatched total cable length the calibration accuracy of the transmitter?\u003c\/p\u003e\n\u003cp\u003eA: The internal eddy-current probe scaling is hard-calibrated for an exact 7.0-meter system length option. Interfacing a 5.0-meter or 9.0-meter transducer array alters the core matching impedance, leading to substantial linearity errors and inaccurate gap voltage validation metrics.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swap removal of the sensor input or the output current loop permitted during active monitoring?\u003c\/p\u003e\n\u003cp\u003eA: Removing the field terminal plugs while energized will not structurally damage the transmitter, but it instantly forces the 4-20 mA loop to fault boundaries, which can trip downstream machinery protection relays if interlocks are not explicitly bypassed.\u003c\/p\u003e\n\u003cp\u003eQ: What are the target baseline values for checking the initial sensor alignment gap voltage?\u003c\/p\u003e\n\u003cp\u003eA: Initial mechanical installation should align the probe until the transmitter output checks out around a centered negative DC voltage target, ensuring the target remains within the linear measurement zone for proper peak-to-peak tracking.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026877632685,"sku":"990-04-70-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/990-04-70-02-00-2.jpg?v=1780306604","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-990-04-70-02-00-990-series-vibration-transmitter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}