{"product_id":"bently-nevada-9200-01-01-10-00-seismoprobe-velocity-transducers","title":"Bently Nevada 9200-01-01-10-00 Seismoprobe Velocity Transducers","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 9200-01-01-10-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVelocity Transducer, operates as a dedicated hardware component for casing vibration velocity measurement within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e9200\u003c\/strong\u003e: Seismoprobe Velocity Transducer base model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Mounting Option variant (1\/2-20 UNF stud mount).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Calibration\/Frequency Option selection (Standard 15 Hz to 1000 Hz operating band).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Connector Option setting (Top-mounted 2-pin Mil-C-5015 hermetic connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval option (No standard hazardous area certification flags specified for this design matrix).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9200-01-01-10-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.0 cm x 8.0 cm x 8.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-29 deg C to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (Self-generating electro-magnetic moving-coil mechanism)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 mV\/mm\/s (500 mV\/in\/s) nominal sensitivity at 100 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 Hz to 1000 Hz (Within +\/- 3.0 dB limits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrientation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical mounting orientation constraints apply to this variant (+\/- 10 deg maximum deviation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCasing Vibration Dynamics and Rotor Tracking\u003c\/h3\u003e\n\u003cp\u003eThe 9200-01-01-10-00 utilizes a moving-coil and permanent magnet geometry to generate a voltage signal directly proportional to absolute structural velocity. Unlike proximity probes that monitor relative shaft displacement through eddy-current probe scaling and require strict gap voltage validation (-10 VDC targets), this seismic sensor captures high-frequency casing energy transmitted by structural rotor dynamics.\u003c\/p\u003e\n\u003cp\u003eThe passive electromechanical system operates independently of external power loops. Internal structural damping metrics prevent resonant amplification within the specified tracking bandwidth, while physical shielding measures guarantee external cross-talk suppression when mounted near high-induction motor frames or alternating current exciters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this passive moving-coil velocity transducer require external power supply loops from the monitor card?\u003c\/p\u003e\n\u003cp\u003eA: No. The 9200 hardware architecture uses an internal coil moving through a magnetic field to output a self-generated voltage signal. It does not pull power or bias currents from the processing monitor backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What are the measurement errors if this vertical-mount variant is installed at a 45-degree angle?\u003c\/p\u003e\n\u003cp\u003eA: Installing this specific vertical configuration past its maximum +\/- 10 deg orientation limit increases internal mechanical friction on the suspension springs. This leads to non-linear responsiveness, calibration shift, and potential locking of the internal mass tracking rotor dynamics.\u003c\/p\u003e\n\u003cp\u003eQ: Can this sensor be hot-swapped while the machinery monitoring loops are live?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The passive nature of the transducer loop permits direct physical substitution. However, disconnecting the Mil-C-5015 terminal interface will drop the signal loop to zero, which registers as a channel fault or sensor failure at the monitor chassis, requiring manual bypass activation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Torque Limits\u003c\/strong\u003e: Secure the 1\/2-20 UNF mounting stud to the machined surface using an exact mechanical torque of 13.5 N-m (120 in-lb). Insufficient torque introduces high-frequency mechanical signal attenuation across the interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurface Preparation\u003c\/strong\u003e: The mounting surface must be machined flat to within 0.025 mm (0.001 in) total indicator reading with a surface finish of 0.8 micrometers (32 microinches) or better to optimize frequency transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Strain Relief\u003c\/strong\u003e: Ensure the two-pin interconnect cable is physically anchored within 150 mm (6.0 in) of the sensor housing to prevent wire fatigue from continuous casing vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Continuity\u003c\/strong\u003e: The signal cable shield must run isolated from the transducer housing and structural casing ground, terminating exclusively at the instrumentation panel ground terminal to eliminate parasitic current loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard delivery item contains:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e(1) 9200-01-01-10-00 Seismoprobe Velocity Transducer hardware assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(1) 1\/2-20 UNF threaded mounting stud adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Nitrile interface environmental sealing washer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Factory conformance calibration datasheet certificate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eDelivery and Handling Profiling\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransit Timeline\u003c\/strong\u003e: 2-7 days when payment finish through standard commercial clearing paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogistics Distribution\u003c\/strong\u003e: Dispatched globally via high-priority air express utilizing DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Containment\u003c\/strong\u003e: Encapsulated within specialized anti-static industrial packaging lined with multi-axis molded foam protection barriers to ensure internal mechanical alignments are preserved during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518869397677,"sku":"9200-01-01-10-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-9200-01-01-10-00-seismoprobe-velocity-transducers-iigxxgq25t1.jpg?v=1766980634","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-9200-01-01-10-00-seismoprobe-velocity-transducers","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}