{"product_id":"bently-nevada-84661-50-interconnect-cable-velomitor-series","title":"Bently Nevada 84661-50 Interconnect Cable Velomitor Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 84661-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e84661\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable utilized to execute analog vibration signal transmission across Velomitor Piezoelectric Velocity Transducer platforms. The component establishes a constant physical and electrical connection between the field-mounted velocity sensor and the central machinery protection monitor rack, routing dynamic casing vibration data without signal degradation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e84661-50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 25.0 cm x 6.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-34 deg C to +100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive component (0.0 W structural power consumption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.2 meters (50 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTinned copper, twisted pair configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyethylene conductor insulation with outer polyurethane jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShielding Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% coverage aluminum-mylar foil with tinned copper drain wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pin socket MIL-C-5015 moisture-resistant connector to terminal lugs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 84661-50 cable assembly is engineered to maintain analog transmission precision under harsh operating parameters driven by high-velocity rotor dynamics. The twisted-pair geometry delivers a balanced impedance path that optimizes cross-talk suppression and isolates the low-voltage vibration signal from adjacent electromagnetic noise generated by heavy industrial machinery.\u003c\/p\u003e\n\u003cp\u003eUnlike proximity systems that focus on gap voltage validation (-10 VDC targets) and eddy-current probe scaling, this interconnect link focuses entirely on preserving the integrity of alternating current (AC) signals representing absolute casing velocity. The shielded architecture ensures that phase and amplitude data remain uncorrupted over the entire 50-foot run.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this interconnect cable line be severed and spliced manually in the field if physical length adjustments are required?\u003c\/p\u003e\n\u003cp\u003eA: No. Splicing raw conductors introduces localized impedance variances and compromises the continuous shield barrier. This disrupts cross-talk suppression and introduces stray noise into the vibration loop. If alternative distances are required, a factory-terminated length must be specified.\u003c\/p\u003e\n\u003cp\u003eQ: Is this specific cable model designed to withstand continuous exposure to submerged synthetic lubricating oil environments?\u003c\/p\u003e\n\u003cp\u003eA: No. The outer polyurethane jacket provides splash resistance against industrial oils, but it is not specified for permanent immersion. For continuous immersion, a Teflon or stainless steel armored outer casing option must be used.\u003c\/p\u003e\n\u003cp\u003eQ: What component prevents the MIL-C-5015 connection point from backing off under high mechanical vibration?\u003c\/p\u003e\n\u003cp\u003eA: The connector assembly uses a threaded coupling ring that locks onto the transducer base. Field practice requires tightening the ring completely to ensure the internal rubber boot compresses, providing both moisture exclusion and mechanical friction locking.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Routing Constraints\u003c\/strong\u003e: Pull the cable through dedicated, grounded metal conduit paths. Do not route the interconnect link inside trays containing high-power AC lines, variable frequency drive motor wiring, or switching inductive loads to prevent electromagnetic coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDrain Wire Shield Grounding\u003c\/strong\u003e: Connect the tinned copper drain wire exclusively at one single point, typically inside the monitor rack terminal strip or an intermediate junction box. Keep the transducer end of the shield isolated and floated to prevent ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius Specifications\u003c\/strong\u003e: Maintain a minimum static bend radius of 38.0 mm (1.5 in) during installation routing. Avoid tight kinks or hard compression clamps that distort the internal twisted-pair symmetry or tear the aluminum foil layer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Weatherproofing\u003c\/strong\u003e: Before engaging the 2-pin socket interface, ensure the contacts are free of moisture and grease. Thread the collar tightly by hand to seal the boot against the sensor housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupply Manifest\u003c\/h3\u003e\n\u003cp\u003eThe standard package contains the following components:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Bently Nevada 84661-50 Interconnect Cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Integrated moisture-resistant terminal connector boot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Technical installation guide insert.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eProcurement Logistics Profile\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDispatch Window\u003c\/strong\u003e: Material moves to active shipment within 2-7 days when payment finish through verified institutional commercial banking networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransit Routing\u003c\/strong\u003e: Forwarded globally using priority express carriers including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging Integrity\u003c\/strong\u003e: Enclosed inside thick anti-static industrial packaging sleeves to safeguard the internal copper conductors and shielding layers against environmental oxidation and static discharges during flight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518867660973,"sku":"84661-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-84661-50-velomitor-interconnect-cable-dqkndijezhc.jpg?v=1766980573","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-84661-50-interconnect-cable-velomitor-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}