{"product_id":"bently-nevada-3500-91-egd-communication-gateway-module-161204-01","title":"Bently Nevada 3500\/91 EGD Communication Gateway Module 161204-01","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-310 citation-end-310\"\u003eThe 3500\/91 EGD (Ethernet Global Data) Gateway Module is a high-performance communication interface designed specifically for the Bently Nevada 3500 Series Machinery Protection System.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis module acts as a bridge, translating internal system data into standardized protocols for seamless integration with Distributed Control Systems (DCS), Human Machine Interfaces (HMI), and PLC networks. By providing a high-speed digital data link, it eliminates the need for extensive hard-wiring while ensuring that critical vibration and status information is accessible across the plant network.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-309 citation-end-309\"\u003eIt supports bidirectional communication, allowing for both data acquisition and remote configuration of the monitoring rack.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/91 (EGD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e161204-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet TCP\/IP, RS232, and RS422\/485 Serial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.4 Watts (Typical Consumption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241 mm x 24.4 mm x 103 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.85 kg (1.87 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-308\"\u003e\u003c\/span\u003e\u003cstrong\u003eNetwork Protocols:\u003c\/strong\u003e\u003cspan class=\"citation-308 citation-end-308\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with Ethernet Global Data (EGD) and Modbus (via serial) for flexible industrial interfacing.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in hardware diagnostics to ensure continuous data transmission and link health monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Slot:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOccupies one full-height slot in the 3500 rack, typically located in the position reserved for communication modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Latency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for real-time reporting of machinery protection parameters and alarm statuses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStrategic Industrial Deployment\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/91 module is engineered for environments where downtime is not an option and real-time data visibility is a requirement for safety and efficiency.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHydrocarbon Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegration of turbine and compressor vibration data into plant-wide safety instrumented systems (SIS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring of large-scale steam and gas turbines to prevent catastrophic mechanical failure through early fault detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater Treatment Facilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCoordinating remote pump station health data with centralized control rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Manufacturing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsuring the stability of high-speed rotating assets in hazardous or corrosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMining and Metallurgy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking the structural health of heavy-duty crushers and conveyor drive systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 3500\/91 module support redundant network configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is designed to support redundant communication paths to ensure that data flow remains uninterrupted even if a single cable or network switch fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to configure other 3500 modules through this gateway?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 3500\/91 allows for remote configuration and tuning of the various monitor modules within the rack, which significantly simplifies maintenance tasks by reducing the need for local physical connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between EGD and standard Modbus communication in this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: EGD (Ethernet Global Data) is optimized for high-speed, producer-consumer data exchange over Ethernet, whereas the Modbus capabilities allow for legacy support and integration with a wider variety of third-party PLCs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be installed in any slot in the 3500 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the gateway module must be installed in specific slots designated for communication or interface modules, typically located next to the Power Supply or Rack Interface Module (RIM).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the module if the operating temperature exceeds 65°C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Operating the module above its rated temperature can lead to component degradation or unexpected thermal shutdowns; proper rack ventilation or cooling should be maintained to ensure the unit stays within its -30°C to +65°C range.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45840888725677,"sku":"161204-01","price":799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/161204-01.jpg?v=1774247747","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-3500-91-egd-communication-gateway-module-161204-01","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}