{"product_id":"bently-nevada-3500-61-163179-02-temperature-monitor-3500-series-module","title":"Bently Nevada 3500\/61 163179-02 Temperature Monitor 3500 Series Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/61 163179-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etemperature monitor module, operates as a dedicated hardware component for multi-channel temperature acquisition and signal conditioning within the 3500 Machinery Protection System rack architecture. It processes RTD and thermocouple inputs, converting analog temperature signals into rack-level monitored values with alarm comparison against user-defined setpoints.\u003c\/p\u003e\n\u003ch3\u003eSuffix \/ Configuration Interpretation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e3500\/61: Temperature monitor module with recorder outputs per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e163179-02: Specific assembly and I\/O configuration variant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRTD\/TC compatibility: Configurable via 3500 rack configuration software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel architecture: 6 independent measurement channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specification Table\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/61 163179-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.6 x 25.3 x 24 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eRTD \/ Thermocouple (TC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MOhm per lead input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy Current and Thermal Monitoring Signal Conditioning (Bently Nevada Mechanical Monitoring Characteristics)\u003c\/h3\u003e\n\u003cp\u003eIn Bently Nevada 3500-series architecture, temperature monitoring modules operate alongside eddy-current proximity and vibration channels within the same rack environment. The 3500\/61 performs temperature signal linearization and scaling prior to alarm comparison logic execution. In mixed measurement systems, thermal drift correlation with rotor dynamics and gap voltage reference stability (nominal negative voltage reference scaling behavior in proximity systems) is used for cross-channel diagnostic interpretation. Channel separation design and TC isolation variants (up to 250 VDC channel-to-channel isolation) reduce electrical cross-interference in densely packed turbine monitoring racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 3500\/61 accept mixed RTD and TC inputs simultaneously?\u003cbr\u003eA: Yes. The non-isolated configuration allows mixed RTD and TC input assignment per channel via rack configuration software.\u003c\/p\u003e\n\u003cp\u003eQ: What is the function of recorder outputs in this module?\u003cbr\u003eA: Each of the six channels provides individual recorder outputs used for external trending or data acquisition systems.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swap replacement in a live rack?\u003cbr\u003eA: The 3500 system supports module replacement under rack power conditions; however, signal interruption occurs during physical extraction and reinsertion.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation level is available in TC isolated versions?\u003cbr\u003eA: TC isolated versions provide 250 VDC channel-to-channel isolation to reduce interference between thermocouple inputs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall module in designated 3500 rack slot only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure backplane connector alignment before insertion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain proper shielding for TC\/RTD signal wiring to reduce EMI coupling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse twisted shielded pairs for thermocouple leads where applicable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify configuration settings in 3500 rack software prior to energization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid routing temperature input cables parallel to high-power switching lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 3500\/61 163179-02 Temperature Monitor Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard rack interface connector integrated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory configuration dependent on RTD\/TC version\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo external accessories included unless specified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration data and software not included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days after payment confirmation or 2-7 days depending on logistics routing. Shipment via DHL \/ FedEx \/ UPS with anti-static industrial packaging designed for electronic rack modules and vibration-sensitive instrumentation hardware.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026906796205,"sku":"163179-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/163179-02_1.jpg?v=1779956049","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-3500-61-163179-02-temperature-monitor-3500-series-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}