{"product_id":"bently-nevada-3500-15-05-05-05-power-supply-assembly-106m1079-01-106m1081-01","title":"Bently Nevada 3500\/15-05-05-05 Power Supply Assembly 106M1079-01 106M1081-01","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-717\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15-05-05-05\u003c\/strong\u003e\u003cspan class=\"citation-717 citation-end-717\"\u003e\u003cspan\u003e \u003c\/span\u003eis a complete Universal AC power solution designed for the 3500 Series Machinery Protection System.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis specific configuration bundles the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106M1079-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106M1081-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Input Module (PIM) to create a comprehensive energy interface for industrial monitoring racks.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-716 citation-end-716\"\u003eEngineered for global deployment, the \"05\" variant accepts a wide-range input of 85 to 264 Vac rms, ensuring seamless operation across varying international voltage standards.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAs the primary power hub, it converts high-voltage utility current into the regulated, low-noise DC voltages required by vibration monitors and rack interface modules.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-715 citation-end-715\"\u003eThe architecture is optimized for high-availability applications, supporting redundant, hot-swappable installations that prevent system-wide downtime during maintenance or individual component failure.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCore Hardware Parameters and Engineering Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal AC Power Supply (106M1079-01) and Power Input Module (106M1081-01)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Spectrum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e85 to 264 Vac rms (Full Range Universal AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Frequency Tolerance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e47 to 63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Conversion Type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWide-range switching mode with high thermal efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Redundancy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports \"Hot-Standby\" dual-module setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated front-panel LED diagnostics for health and voltage status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated PIM-level surge suppression and EMI filtration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-714\"\u003e\u003c\/span\u003e\u003cstrong\u003eTotal Assembly Mass\u003c\/strong\u003e\u003cspan class=\"citation-714 citation-end-714\"\u003e\u003cspan\u003e \u003c\/span\u003e1.39 kg\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Proportions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e25.15 cm x 5.08 cm x 12.07 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTariff Classification (HS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Deployment Context\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-05-05-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the preferred power assembly for modernizing existing Bently Nevada 3500 racks or for new installations in refineries, thermal power plants, and offshore platforms. Its wide-range voltage support eliminates the need for manual hardware adjustments when moving between 110V and 220V grids. In mission-critical machinery protection loops, this assembly is typically deployed in a redundant pair; if the primary supply fails, the secondary unit instantly assumes the full electrical load without interrupting the monitoring of high-value turbines or compressors. The inclusion of the 106M1081-01 PIM ensures that the current entering the rack is conditioned to protect high-precision sensor electronics from the electrical volatility common in heavy industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 3500\/15-05-05-05 replace both legacy high and low voltage AC supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-713 citation-end-713\"\u003eA: Yes, the Universal AC architecture is designed to handle the full range of AC inputs from 85 to 264 Vac, effectively replacing the need for separate high-voltage or low-voltage specific units.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 106M1081-01 Power Input Module (PIM) required for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. The PIM is the physical interface at the rear of the rack where the power cord connects. It works in tandem with the 106M1079-01 supply module to provide filtering and protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I hot-swap this power supply if my rack is currently running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If your 3500 rack is configured with redundant power supplies (two modules), you can safely replace one 106M1079-01 while the system remains live without losing machinery protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What do the front-panel LEDs indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"Supply OK\" LED confirms the module is receiving power and providing the correct output voltages. If the LED is off, it indicates a hardware fault or a loss of incoming AC power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the weight listed as 1.39 kg?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This represents the total mass of the 3500\/15-05-05-05 assembly, including both the front-loading supply module and the rear-mounting input module.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45832416723117,"sku":"3500\/15-05-05-05","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3500-15yitao1.jpg?v=1767938850","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-3500-15-05-05-05-power-supply-assembly-106m1079-01-106m1081-01","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}