{"product_id":"bently-nevada-330930-060-02-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-060-02-05 3300 NSv Extension Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330930-060-02-05 serves as a critical link within the 3300 NSv (Near Surface) Proximity Transducer System. Engineered specifically for centrifugal air compressors, refrigeration compressors, and other machinery with tight installation constraints, this extension cable ensures the seamless transmission of high-frequency eddy current signals from the probe to the Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eIn demanding industrial environments where precision is non-negotiable, the 3300 NSv system excels by providing accurate radial vibration and axial position data, even when target surfaces are smaller than standard probes can accommodate. This cable maintains signal integrity across its entire length, resisting EMI interference and mechanical stress. By deploying this original Bently Nevada component, plant operators secure the reliability of their Turbine Supervisory Instrumentation (TSI) and prevent costly unplanned downtime in critical rotating assets.\u003c\/p\u003e\n\u003ch2\u003eModel Suffix Identification\u003c\/h2\u003e\n\u003ch3\u003e330930-060-02-05 Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric suffix code determines the physical and regulatory configuration of the extension cable to ensure compatibility with specific housing and site requirements.\u003c\/p\u003e\n\u003ch3\u003eCable Length (-060)\u003c\/h3\u003e\n\u003cp\u003eThis indicates a total cable length of 6.0 meters (approximately 19.7 feet). Proper length selection is vital to maintain the tuned resonant frequency of the Proximitor circuit.\u003c\/p\u003e\n\u003ch3\u003eConnector and Cable Option (-02)\u003c\/h3\u003e\n\u003cp\u003eThis designates the use of a standard cable with Fluoroelastomer (FEP) insulation. It includes miniature coaxial connectors that provide a secure, low-impedance connection while maintaining a small footprint for tight conduits.\u003c\/p\u003e\n\u003ch3\u003eAgency Approval (-05)\u003c\/h3\u003e\n\u003cp\u003eThe -05 suffix confirms Multiple Approvals, encompassing ATEX, IECEx, and North American standards (CSA\/NRTL) for use in Class I, Division 1 and Zone 0\/1 hazardous areas.\u003c\/p\u003e\n\u003ch2\u003ePhysical and Performance Parameters\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-060-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85444290\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg (Approximate)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 x 25.4 x 5.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +351°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Bend Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDeployment and Field Best Practices\u003c\/h2\u003e\n\u003ch3\u003eConnector Torque and Protection\u003c\/h3\u003e\n\u003cp\u003eAlways hand-tighten the coaxial connectors. For permanent installations, apply the recommended silicone lubricant to the connector threads and use heat-shrink tubing or Bently Nevada connector protectors to prevent moisture ingress and vibration-induced loosening.\u003c\/p\u003e\n\u003ch3\u003eRouting and Shielding\u003c\/h3\u003e\n\u003cp\u003eAvoid routing the extension cable parallel to high-voltage AC power lines to minimize electromagnetic interference. Utilize grounded metal conduits or cable trays wherever possible. Ensure the shield is only grounded at the Proximitor end to prevent ground loops that can distort vibration data.\u003c\/p\u003e\n\u003ch3\u003eBend Radius Constraints\u003c\/h3\u003e\n\u003cp\u003eNever exceed the minimum bend radius of 25.4 mm. Sharp kinks or tight bends permanently alter the coaxial impedance, leading to \"false\" vibration readings or signal attenuation that compromises the accuracy of the DCS or 3500 Monitoring System.\u003c\/p\u003e\n\u003ch2\u003eCritical Reliability Advantages\u003c\/h2\u003e\n\u003ch3\u003eOptimized for Small Shaft Diameters\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv series is specifically tuned for targets as small as 5 mm (0.2 in), where standard 5mm or 8mm probes fail due to side-viewing effects. This cable ensures the system retains its 7.87 V\/mm (200 mV\/mil) sensitivity across these challenging geometries.\u003c\/p\u003e\n\u003ch3\u003eExtreme Chemical Resistance\u003c\/h3\u003e\n\u003cp\u003eThe FEP jacket provides superior protection against caustic fluids, synthetic lubricants, and moisture common in compressor and turbine decks. This ensures the cable does not degrade or become brittle over years of continuous operation.\u003c\/p\u003e\n\u003ch3\u003eSeamless TSI Integration\u003c\/h3\u003e\n\u003cp\u003eFully compatible with the Bently Nevada 3500\/42M or 3500\/40M monitors. It provides the high-fidelity input necessary for advanced diagnostics in System 1 software, allowing for precise orbit and trend analysis.\u003c\/p\u003e\n\u003ch2\u003eGlobal Logistics and Fulfillment\u003c\/h2\u003e\n\u003ch3\u003eRapid Dispatch\u003c\/h3\u003e\n\u003cp\u003eWe guarantee shipping within 2-5 days after payment verification. All units are shipped via premium carriers including DHL, FEDEX, or UPS to ensure door-to-door tracking and security.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Grade Packaging\u003c\/h3\u003e\n\u003cp\u003eEvery cable is shipped in specialized anti-static industrial packaging. We utilize vacuum-sealed moisture barriers and reinforced outer cushioning to ensure the product arrives in factory-perfect condition, ready for immediate field commissioning.\u003c\/p\u003e\n\u003ch2\u003eTechnical Field Support\u003c\/h2\u003e\n\u003cp\u003eQ1: Can I use this 330930 extension cable with a standard 3300 XL 8mm probe?\u003c\/p\u003e\n\u003cp\u003eA1: No. The 330930 is part of the NSv (Near Surface) system. It has specific electrical characteristics tuned for the NSv probe and Proximitor. Mixing it with XL 8mm components will result in significant calibration errors.\u003c\/p\u003e\n\u003cp\u003eQ2: What is the total allowable system length for the 3300 NSv?\u003c\/p\u003e\n\u003cp\u003eA2: The 3300 NSv system is designed for a total electrical length of 5.0 meters or 7.0 meters. The -060 (6m) cable is typically used with a 1m probe to achieve the 7.0m total system calibration.\u003c\/p\u003e\n\u003cp\u003eQ3: Is a special tool required for the connectors?\u003c\/p\u003e\n\u003cp\u003eA3: While they can be finger-tightened, we recommend using a 3300 XL connector tool to ensure the specific torque is met without damaging the miniature coaxial threads.\u003c\/p\u003e\n\u003cp\u003eQ4: How do I verify if the cable is damaged after installation?\u003c\/p\u003e\n\u003cp\u003eA4: Perform a continuity and isolation test. Resistance between the center conductor and the shield should be infinite (open), and the resistance of the center conductor from end to end should be low and consistent with its length (approx. 0.5 to 1.5 ohms).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518908096685,"sku":"330930-060-02-05","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-060-02-05-3300-nsv-extension-cable-h14fuammh1c.jpg?v=1766981337","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330930-060-02-05-3300-nsv-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}