{"product_id":"bently-nevada-330930-060-00-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-060-00-05 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330930-060-00-05\u003c\/strong\u003e is a high-performance \u003cstrong\u003e3300 NSv Extension Cable\u003c\/strong\u003e engineered for critical proximity transducer systems. The 3300 NSv (Near Surface void) platform is specifically optimized for machinery configurations where tight mounting clearances, small target sizes (less than 9.5 mm), or narrow linear ranges restrict the deployment of standard 8mm sensors. It serves as the vital RF impedance-matched link between the 3300 NSv proximity probe and the 3300 NSv Proximitor Sensor.\u003c\/p\u003e\n\u003cp\u003eThis model features a total physical length of \u003cstrong\u003e6.0 meters (19.7 feet)\u003c\/strong\u003e, standard unarmored coaxial construction, and a patented miniature coaxial ClickLoc connector assembly. Reinforced with the \u003cstrong\u003e05 Multiple Approvals\u003c\/strong\u003e protocol, it complies with international intrinsic safety regulations for deployment in hazardous industrial processing locations. It ensures clean signal propagation for radial vibration, axial position, and high-frequency tachometer measurements without introducing electrical noise or impedance mismatches.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930-060-00-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImpedance-Matched Proximity Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length (060)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor \/ Conduit Option (00)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard coaxial cable (Without stainless steel armor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approvals (05)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (ATEX, IECEx, CSA Intrinsic Safety Class I Div 1\/2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStrictly 3300 NSv 5.0m or 7.0m loops (Probe dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 Ω nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated coaxial ClickLoc (1 male, 1 female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluorinated Ethylene Propylene (FEP) jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lb) maximum continuous pull-force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.5 * 18.0 * 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe model identifier \u003cstrong\u003e330930-060-00-05\u003c\/strong\u003e breaks down into factory-defined engineering parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330930\u003c\/strong\u003e: Core platform series designation for the 3300 NSv Proximity Extension Cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e060\u003c\/strong\u003e: \u003cstrong\u003eCable Length Option.\u003c\/strong\u003e Evaluates to exactly 6.0 meters of physical cable. This length is critical for reaching remote hazardous area field junction boxes from the machine casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: \u003cstrong\u003eConnector and Armor Option.\u003c\/strong\u003e Configured without structural stainless steel armor. Provides maximum routing flexibility within protective structural field conduits or enclosed terminal trunks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: \u003cstrong\u003eAgency Approval Option.\u003c\/strong\u003e Multiple Approvals package. Combines ATEX, IECEx, and North American CSA certifications for globally harmonized intrinsic safety compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Compressors:\u003c\/strong\u003e Monitoring internal small-diameter thrust collars and radial shaft profiles where tight spaces prohibit standard 8mm probe placement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHydroelectric Turbines:\u003c\/strong\u003e Tracking shaft runout and phase-reference angles in tight packing glands or wet operational zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAeroderivative Gas Turbines:\u003c\/strong\u003e High-accuracy rotor dynamics and speed telemetry tracking inside compact, high-temperature casing envelopes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Gearboxes:\u003c\/strong\u003e Measuring high-speed input and output shaft vibrations next to gear teeth where spatial constraints are severe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 330930-060-00-05 extension cable is a matched component within a tuned radio frequency (RF) tank circuit. It is not interchangeable with other Bently Nevada platform components.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximity Probes:\u003c\/strong\u003e Connects exclusively to \u003cstrong\u003e3300 NSv Proximity Probes\u003c\/strong\u003e (such as the 330901 or 330902 series). It requires a 1.0-meter integrated probe cable to establish a calibrated 7.0-meter system loop, or a 0.5-meter probe for a 6.5-meter system loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximitor Sensors:\u003c\/strong\u003e Must interface directly with a \u003cstrong\u003e3300 NSv Proximitor Sensor\u003c\/strong\u003e (Model 330980). Connecting this cable to a standard 3300 XL 5m\/9m Proximitor will cause severe scale factor errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachinery Protection Racks:\u003c\/strong\u003e Routes conditioned voltage signals directly to the input channels of the \u003cstrong\u003eBently Nevada 3500\/42M Proximitor Seismic Monitor\u003c\/strong\u003e module or structural 3701D Trendmaster platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCritical Routing Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosed Conduit Protection:\u003c\/strong\u003e Because this model is unarmored (00 option), always route the cable inside dedicated, grounded metal conduits to shield the signal from external electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnforce Bend Radii Limits:\u003c\/strong\u003e Maintain a strict minimum bend radius of 25.4 mm (1.0 inch) during structural routing. Kinking changes the internal spacing of the coaxial layers, creating impedance shifts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Insulation Isolation:\u003c\/strong\u003e Use standard connector silicone boots or clear heat-shrink tubing to fully insulate the ClickLoc union inside junction boxes. Do not let the metal connector body touch the grounded enclosure wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Tie Tensioning:\u003c\/strong\u003e Secure the FEP jacketed cable with nylon zip ties at regular intervals. Tighten ties snugly to prevent structural chafing, but avoid crushing or pinching the cable outer diameter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistance Tracking:\u003c\/strong\u003e Never splice, cut, or shorten this extension cable. The 6.0-meter length is electrically tuned to the Proximitor oscillator; length changes will destroy measurement calibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for Tight Spaces:\u003c\/strong\u003e The unarmored FEP jacket profile allows for tight routing through internal bracket ports and small machine cavities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudible ClickLoc Locking:\u003c\/strong\u003e Gold-plated brass terminations snap together firmly, preventing field disconnects caused by continuous industrial vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Thermal Performance:\u003c\/strong\u003e Maintains constant characteristic capacitance and resistance from -51°C to +177°C, minimizing signal drift across wide ambient shifts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Drop-In Interchangeability:\u003c\/strong\u003e Manufactured to exact tolerances so that individual field units can be swapped out without requiring total loop recalibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Ordering Identification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eStructural Specifications Summary\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eStatus \u0026amp; Allocation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330930-060-00-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable, 6.0m Length, Unarmored, Multiple Approvals (ATEX\/IECEx\/CSA)\u003c\/td\u003e\n\u003ctd\u003eWorldwide MRO Stock \/ RFQ Processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLogistics and Shipping\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Packaging Protocol:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery Bently Nevada 330930 extension cable is packed within an \u003cstrong\u003eanti-static industrial packaging shield\u003c\/strong\u003e to fully isolate the internal dielectric layers from electrostatic discharge hazards. The cable coil is fixed flat to eliminate twisting or kinking forces, placed inside custom shock-absorption foam chambers, and shipped in a rugged corrugated structural exterior box to ensure safe international transit.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan this 3300 NSv extension cable be paired with a standard 3300 XL 8mm proximity probe?\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 NSv series operates on distinct electrical parameters and tuning frequencies optimized for small-target applications. Interfacing this cable with an 8mm probe disrupts the calibrated system impedance, rendering the output data completely inaccurate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the physical length of this extension cable is altered in the field?\u003c\/p\u003e\n\u003cp\u003eCutting or splicing the cable modifies its total nominal capacitance and characteristic impedance. This shifts the tuned RF circuit loop away from the Proximitor factory specification, corrupting the 200 mV\/mil scale factor and causing major tracking errors on protection monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the lack of stainless steel armor on the 00 option affect signal quality?\u003c\/p\u003e\n\u003cp\u003eNo, the electrical shielding remains high. The unarmored designation simply means it lacks an exterior physical metal mesh wrapper. The coaxial core contains a full shield layer. External metallic conduit routing is required to supply mechanical impact defense.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do you confirm the electrical health of a 330930 cable using a multimeter?\u003c\/p\u003e\n\u003cp\u003eDisconnect both ends. Measure the resistance of the center conductor from pin to socket; it should read near 0 Ω. Then measure resistance from the center pin to the outer shell; it must show an infinite open circuit, confirming no internal insulation failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the gold plating on the ClickLoc coaxial connectors?\u003c\/p\u003e\n\u003cp\u003eGold plating prevents oxidation and surface corrosion in high-humidity or chemically active environments. It ensures low contact resistance across years of field service, preventing signal attenuation or thermal noise generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs a specialized tool needed to link or unlock the ClickLoc connector interfaces?\u003c\/p\u003e\n\u003cp\u003eNo. ClickLoc connectors engage via a manual push-and-twist mechanism that locks into place with an audible snap. They are designed for quick field connection and removal without requiring specialty wrenches or crimping pliers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific hazard protection mechanisms are included in the \"05\" certification?\u003c\/p\u003e\n\u003cp\u003eThe \"05\" multi-approval framework certifies the hardware for Intrinsic Safety (IS) and Non-Incendive installations when deployed through matching galvanic barriers or Proximitor isolators. It satisfies global ATEX, IECEx, and CSA requirements for Zone 0, 1, and 2 deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy does the 3300 NSv system use a 95-ohm coaxial design rather than standard 50-ohm hardware?\u003c\/p\u003e\n\u003cp\u003eThe 95 Ω characteristic impedance is specifically engineered by Bently Nevada to optimize the RF energy transmission envelope for the NSv probe tip profile, maximizing sensitivity over narrow target diameters and small linear gaps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518847738029,"sku":"330930-060-00-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-060-00-05-3300-nsv-extension-cable-nbudfawrvqx.jpg?v=1766980355","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330930-060-00-05-3300-nsv-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}