{"product_id":"bently-nevada-330930-040-05-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-040-05-05 3300 NSv Extension Cable","description":"\u003cp\u003eConfigured for signal transmission between 3300 NSv proximity probes and associated monitoring sensors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-040-05-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) serves as a specialized interconnection component. This hardware maintains strict impedance characteristics for the low-frequency radio signal path, ensuring accurate displacement data acquisition within the 3300 NSv platform.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330930: 3300 NSv Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e040: Cable Length (4.0 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Connector Type (Miniature ClickLoc)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency Approval (Multiple approvals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-040-05-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 20 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Passive loop)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm (nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Integrity \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv system is optimized for near-surface (NSv) proximity measurement, requiring specific eddy-current probe scaling to handle targets in constrained spaces. The extension cable acts as a calibrated component of the resonant circuit. Maintaining a -10 VDC gap voltage target at the Proximitor output is required to ensure signal linearity. Proper cross-talk suppression is achieved by keeping coaxial signal paths isolated from high-frequency power lines, which prevents induced noise that could otherwise compromise the analysis of rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330930-040-05-05 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Pre-installed connector protectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical compliance documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Routing Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBending Radius: Maintain a minimum bend radius of 38 mm to preserve internal cable geometry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Requirements: Route cables within dedicated metallic conduit to provide shielding against electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Security: Ensure the ClickLoc interface is fully engaged; an audible or tactile click indicates proper mechanical seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironment: Use provided connector protectors to seal interfaces against moisture and particulate contamination in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain signal common isolation from the chassis ground to prevent the introduction of ground loops into the measurement circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be used with standard 3300 XL probes?\u003c\/p\u003e\n\u003cp\u003eA: No, the 3300 NSv cable is electrically tuned for NSv probes and components; mixing with 3300 XL parts will cause signal non-linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the impact of changing the cable length?\u003c\/p\u003e\n\u003cp\u003eA: The system is factory-calibrated for a specific total length. Altering this length shifts the resonant frequency, rendering the data invalid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the FEP jacket flame-retardant?\u003c\/p\u003e\n\u003cp\u003eA: The FEP material provides robust thermal and chemical resistance consistent with industrial safety standards for rotating machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How to troubleshoot intermittent signal loss?\u003c\/p\u003e\n\u003cp\u003eA: Inspect the ClickLoc connectors for oxidation or debris and verify the cable for physical kinks or jacket breaches that may compromise shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable intrinsically safe?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is compatible with standard Bently Nevada hazardous area barriers, provided the system installation adheres to approved control drawings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How often should connections be inspected?\u003c\/p\u003e\n\u003cp\u003eA: During scheduled machine outages, inspect all connector interfaces for integrity and confirm the gap voltage at the sensor output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I splice this cable if it is too short?\u003c\/p\u003e\n\u003cp\u003eA: No, field splicing is prohibited as it creates impedance discontinuities and signal attenuation that cannot be compensated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the function of the connector protector?\u003c\/p\u003e\n\u003cp\u003eA: It provides a seal against moisture ingress and physical support for the connection in environments exposed to industrial fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518835351725,"sku":"330930-040-05-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-040-05-05-3300-nsv-extension-cable-gslfw01qmod.jpg?v=1766980007","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330930-040-05-05-3300-nsv-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}