{"product_id":"bently-nevada-330910-00-05-02-00-3300-nsv-proximity-extension-cable","title":"Bently Nevada 330910-00-05-02-00 3300 NSv Proximity Extension Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330910-00-05-02-00 serves as a critical signal transmission bridge within the 3300 NSv (Non-Standard vent) proximity transducer system. Specifically engineered for tight mechanical constraints where standard probes cannot fit, this extension cable ensures the seamless delivery of high-frequency eddy current signals from the probe to the proximitor sensor. It plays a vital role in monitoring centrifugal compressors, pumps, and small turbines where radial vibration and axial position data are mandatory for machine health.\u003c\/p\u003e\n\u003cp\u003eThis cable maintains the rigorous electrical impedance required for precise displacement measurements. By utilizing high-quality fluoropolymer insulation, it defends signal integrity against electromagnetic interference and chemical exposure. In high-stakes environments like emergency shutdown systems or DCS-integrated monitoring, this extension cable provides the stability needed to prevent false trips and ensure accurate data for your Honeywell Experion or Bently 3500 platform.\u003c\/p\u003e\n\u003ch2\u003eCable Suffix and Electrical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe 330910 series is defined by specific physical attributes that must match the total system length for accurate calibration.\u003c\/p\u003e\n\u003ch3\u003eCable Length (00-05)\u003c\/h3\u003e\n\u003cp\u003eThe \"05\" suffix designates a 5.0-meter (approximately 16.4 feet) total length. In the 3300 NSv architecture, the total electrical length (probe plus extension cable) must equal either 5 or 7 meters to maintain the calibrated scale factor of the proximitor.\u003c\/p\u003e\n\u003ch3\u003eConnector and Armor Option (02)\u003c\/h3\u003e\n\u003cp\u003eThe \"02\" suffix specifies the inclusion of connector protectors. These fluorosilicone rubber boots seal the connection points against moisture and oil ingress, which is critical for long-term reliability in bearing housings and junction boxes.\u003c\/p\u003e\n\u003ch3\u003eAgency Approvals (00)\u003c\/h3\u003e\n\u003cp\u003eThe \"00\" indicates standard global approvals. This confirms the cable is manufactured to meet rigorous industrial safety standards for non-hazardous and typical process plant installations.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330910-00-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8544.20.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 Meters (16.4 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFEP (Fluorinated Ethylene Propylene)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 °C to +177 °C (-60 °F to +350 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 mm x 200 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConnectivity and Routing Protocol\u003c\/h2\u003e\n\u003cp\u003eSuccess in proximity system performance relies heavily on cable management. This 5-meter extension cable requires a minimum bend radius of 25.4 mm (1.0 inch) to prevent internal coaxial damage. When routing through conduit, ensure the cable is not pulled with excessive force, as stretching the FEP jacket can alter the capacitance and shift the system calibration.\u003c\/p\u003e\n\u003cp\u003eThe Gold-plated Click-Loc connectors must be hand-tightened until they \"click\" to ensure a low-resistance path. Use the included connector protectors (Suffix 02) to bridge the gap between the probe and extension cable, especially in environments where synthetic lubricants or high humidity are present. Proper grounding of the proximitor housing remains the primary defense against ground loops that can distort vibration signals.\u003c\/p\u003e\n\u003ch2\u003eAdvanced Signal Integrity Performance\u003c\/h2\u003e\n\u003cp\u003eThe 3300 NSv extension cable is built for the rigors of Turbine Supervisory Instrumentation (TSI). Its low-capacitance design minimizes signal attenuation over the 5-meter span, allowing the proximitor to accurately resolve micro-inch shaft movements. This level of precision is essential when integrating with high-speed controllers or the 3500\/42M Displacement Monitor, ensuring that your vibration data is a true reflection of mechanical behavior rather than electrical noise.\u003c\/p\u003e\n\u003ch2\u003eOrdering info\u003c\/h2\u003e\n\u003cp\u003e(1) Bently Nevada 330910-00-05-02-00 Extension Cable.\u003c\/p\u003e\n\u003cp\u003e(2) Pre-installed connector protectors (both ends).\u003c\/p\u003e\n\u003cp\u003e(3) Technical data sheet and calibration compliance note.\u003c\/p\u003e\n\u003cp\u003e(4) Protective dust caps for Click-Loc connectors.\u003c\/p\u003e\n\u003ch2\u003eLogistics and Packaging Standards\u003c\/h2\u003e\n\u003cp\u003eYour order is processed for shipment within 3-5 days when payment finish. To protect the sensitive coaxial structure, we utilize anti-static industrial packaging and reinforced outer cartons. Our global logistics network, supported by DHL, FEDEX, and UPS, ensures rapid delivery to site. Every cable is shipped in \"Original Pack\" condition, sealed to prevent environmental degradation before it reaches your facility.\u003c\/p\u003e\n\u003ch2\u003eSystem Integration FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Can I use this 5m extension cable with a 7m proximitor?\u003c\/p\u003e\n\u003cp\u003eA1: Only if the probe length combined with this cable equals 7 meters. Using a 5m cable in a system calibrated for 7m total electrical length will result in an incorrect scale factor and inaccurate vibration readings.\u003c\/p\u003e\n\u003cp\u003eQ2: What is the purpose of the connector protectors included in the -02 option?\u003c\/p\u003e\n\u003cp\u003eA2: They provide an environmental seal at the junction of the probe and extension cable, preventing oil, water, or conductive dust from entering the coaxial connection and causing signal drift.\u003c\/p\u003e\n\u003cp\u003eQ3: Is the 3300 NSv extension cable interchangeable with the standard 3300 XL cable?\u003c\/p\u003e\n\u003cp\u003eA3: No. The 3300 NSv system uses a different coaxial impedance and connector geometry optimized for small-bore applications. Mixing NSv and XL components will lead to system \"Not OK\" status or significant measurement errors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518887747757,"sku":"330910-00-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330910-00-05-02-00-3300-nsv-extension-cable-144ys4wcndt.jpg?v=1766981134","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330910-00-05-02-00-3300-nsv-proximity-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}