{"product_id":"bently-nevada-330901-00-90-10-01-05-3300-nsv-non-armored-proximity-probe","title":"Bently Nevada 330901-00-90-10-01-05 3300 NSv Non-Armored Proximity Probe","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330901-00-90-10-01-05 proximity probe delivers high-fidelity dynamic displacement data from the restricted, high-vibration internal environments of industrial rotating assets. This specialty 3300 NSv (Narrow Side View) sensor generates a tightly focused magnetic field, permitting pristine eddy current measurements in confined layouts where standard-diameter probe tips experience severe side-loading errors or mechanical cross-talk. It monitors critical machinery parameters including radial shaft vibration, axial positioning, and rotor speed. Instrumentation teams integrate this hardware directly into Bently Nevada 3500 protection racks and host Distributed Control Systems (DCS) to manage machinery health. The resulting telemetry drives high-speed emergency shutdown (ESD) automated safety layers, protecting high-value assets such as small centrifuges, high-speed turbocompressors, and aeroderivative gas turbines from catastrophic failure.\u003c\/p\u003e\n\u003ch2\u003eTransducer Nomenclature and Variant Identification\u003c\/h2\u003e\n\u003cp\u003eThe discrete alphanumeric selections within this model structure define the structural footprint, cabling architecture, and explosive atmosphere safety ratings.\u003c\/p\u003e\n\u003ch3\u003e00 - Thread Profile Selection\u003c\/h3\u003e\n\u003cp\u003eThe '00' designation indicates a completely threaded probe body layout. The 1\/4-28 UNF threads extend across the entire usable length of the sensor casing, maximizing structural versatility during field depth positioning inside deep mounting plates or adapter bushings.\u003c\/p\u003e\n\u003ch3\u003e90 - Casing Length Metric\u003c\/h3\u003e\n\u003cp\u003eThis option establishes an extended 9.0-inch total case length. The deep-reach stainless steel barrel provides rigid mechanical support, allowing the sensor tip to penetrate deep into thick machine outer skins or specialized bearing housings to reach the target shaft face securely.\u003c\/p\u003e\n\u003ch3\u003e10 - Cable Length Dimension\u003c\/h3\u003e\n\u003cp\u003eThis option specifies a 1.0-meter (39 inches) integrated flexible coaxial cable. This length provides the necessary physical span to route out of the immediate hot machine core to clean external junction enclosures without suffering premature signal attenuation.\u003c\/p\u003e\n\u003ch3\u003e01 - Connector and Protective Sleeve Profile\u003c\/h3\u003e\n\u003cp\u003eThis suffix dictates a miniature coaxial ClickLoc connector paired with a pre-installed heavy-duty connector protector sleeve over standard flexible non-armored cable. This configuration ensures a minimal bend profile for smooth routing inside narrow industrial conduits.\u003c\/p\u003e\n\u003ch3\u003e05 - Hazardous Environment Authorization\u003c\/h3\u003e\n\u003cp\u003eThe final '05' option code ensures compliance with comprehensive global explosion protection mandates. This configuration carries valid ATEX, CSA, and IECEx approvals, authorizing safe deployment inside volatile chemical processing and upstream oil and gas facilities.\u003c\/p\u003e\n\u003ch2\u003eTransducer Mechanical and Electrical Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Variable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Plant Baseline\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States of America\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Tariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransducer Core Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg (0.31 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Package Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.3 x 22.0 x 3.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Structure Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300-Series Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Polymeric Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4-28 UNF Imperial Fine Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 mm (60 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Ingress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP68 \/ NEMA 4X rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAdvanced Field Gapping and Mechanical Protocol\u003c\/h2\u003e\n\u003cp\u003eField technicians must achieve precise mechanical gapping to place the machine target within the narrow 1.5 mm linear monitoring window of the 3300 NSv transducer. Connect a high-impedance digital multimeter to the corresponding Proximitor Sensor test ports and slowly rotate the 9.0-inch probe casing through the 1\/4-28 UNF mounting bracket until the static DC bias voltage stabilizes at exactly -10.0 VDC.\u003c\/p\u003e\n\u003cp\u003eMaintain a strict minimum cable bend radius of 25.4 mm (1.0 inch) along the unarmored lead to prevent micro-fracturing of the internal coaxial shield. Because this configuration uses an extended 9.0-inch barrel, verify that the probe housing remains perfectly perpendicular to the shaft centerline to prevent structural misalignment. Lock the factory-installed ClickLoc connector protector sleeve tight to shield the critical high-frequency terminal connection from moisture ingress and airborne oil mist.\u003c\/p\u003e\n\u003ch2\u003eMachinery Health System Synergy\u003c\/h2\u003e\n\u003cp\u003eThe 3300 NSv proximity probe excels where minimal target diameters and tight structural side clearances cause standard 8mm sensors to output distorted data. Its unique, concentrated electromagnetic field shape eliminates measurement cross-talk from nearby machine walls, maintaining high stability over long thermal processing cycles.\u003c\/p\u003e\n\u003cp\u003eThe sensor interfaces directly with existing Turbine Supervisory Instrumentation (TSI) setups. It streams unbuffered, real-time impedance data straight to Bently Nevada 3500\/42M monitor modules, creating a high-speed data bridge to plant-wide automation systems like Honeywell Experion PKS or Siemens S7 architectures. This tight integration allows the DCS to compute complex orbital plots and cross-phase transients, providing operators with immediate notice of oil whip, shaft unbalance, or thrust bearing deterioration.\u003c\/p\u003e\n\u003ch2\u003eComplete Shipping Package Manifest\u003c\/h2\u003e\n\u003cp\u003e(1) One genuine Bently Nevada 330901-00-90-10-01-05 3300 NSv proximity probe.\u003c\/p\u003e\n\u003cp\u003e(2) Integrated 1.0-meter standard coaxial cable lead with a ClickLoc terminal.\u003c\/p\u003e\n\u003cp\u003e(3) One pre-installed heavy-duty ClickLoc connector protector sleeve kit.\u003c\/p\u003e\n\u003cp\u003e(4) Technical validation certificate confirming multi-agency ATEX, CSA, and IECEx approvals.\u003c\/p\u003e\n\u003ch2\u003eGlobal Logistics and Asset Protection\u003c\/h2\u003e\n\u003cp\u003eOur global fulfillment group prepares and dispatches orders within 2-7 days after payment finish protocols complete. We coordinate international transit exclusively through premier express carriers including DHL, FEDEX, and UPS to guarantee fast, fully tracked delivery directly to your facility. Prior to dispatch, technicians verify the mechanical and electrical properties of each probe before sealing it within specialized anti-static industrial packaging. This high-density, ESD-shielded containment cushions the extended 9.0-inch stainless steel casing and sensitive internal coils from shipping vibrations and electrostatic hazards, ensuring the component arrives ready for immediate site commissioning.\u003c\/p\u003e\n\u003ch2\u003eHardware Maintenance and Engineering FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does this specific 3300 NSv model utilize an extended 9.0-inch case length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The 9.0-inch case length satisfies deep-reach physical constraints. This long barrel configuration allows the probe tip to safely pass through thick outer insulation jackets, large machine frame castings, or specialized internal cooling jackets to achieve the required calibration gap against the target shaft face.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I substitute a standard 3300 XL 8mm proximity probe with this 3300 NSv series model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: No. The 3300 NSv series operates with a completely different focused magnetic field, a tighter 1.5 mm linear measuring range, and a native scale factor of 200 mV\/mil. Interchanging it with an 8mm probe changes the system tuning, causes invalid calibration metrics, and breaks the asset protection loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I verify the basic electrical status of the internal sensor coil with a standard multimeter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Disconnect the probe from the main extension cable and measure the resistance between the ClickLoc center pin and the outer connector shell. A functional 3300 NSv probe with a 1.0-meter integrated cable typically displays a stable DC resistance value between 4.0 and 6.0 ohms; an infinite resistance reading indicates an open circuit, which means the internal induction coil is damaged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What practical protection does the pre-installed connector protector sleeve offer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The connector protector physically seals the miniature ClickLoc coaxial terminal junction. It blocks fluid migration from process oils, steam, and environmental condensation from penetrating the connection point, preventing high-frequency signal leakage and maintaining continuous calibration accuracy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518882242733,"sku":"330901-00-90-10-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330901-00-90-10-01-05-3300-nsv-proximity-probes-r531d40bnph.jpg?v=1766980927","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330901-00-90-10-01-05-3300-nsv-non-armored-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}